We report on the measurement of the γp→J/ψp cross section from E_{γ}=11.8 GeV down to the threshold at 8.2 GeV using a tagged photon beam with the GlueX experiment. We find that the total cross ...section falls toward the threshold less steeply than expected from two-gluon exchange models. The differential cross section dσ/dt has an exponential slope of 1.67±0.39 GeV^{-2} at 10.7 GeV average energy. The LHCb pentaquark candidates P_{c}^{+} can be produced in the s channel of this reaction. We see no evidence for them and set model-dependent upper limits on their branching fractions B(P_{c}^{+}→J/ψp) and cross sections σ(γp→P_{c}^{+})×B(P_{c}^{+}→J/ψp).
PANDA Phase One Davì, F; Montalto, L; Krusche, B ...
The European physical journal. A, Hadrons and nuclei,
2021, Letnik:
57, Številka:
6
Journal Article
Recenzirano
Odprti dostop
The Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, provides unique possibilities for a new generation of hadron-, nuclear- and atomic physics experiments. The future ...antiProton ANnihilations at DArmstadt (PANDA or P¯ANDA) experiment at FAIR will offer a broad physics programme, covering different aspects of the strong interaction. Understanding the latter in the non-perturbative regime remains one of the greatest challenges in contemporary physics. The antiproton–nucleon interaction studied with PANDA provides crucial tests in this area. Furthermore, the high-intensity, low-energy domain of PANDA allows for searches for physics beyond the Standard Model, e.g. through high precision symmetry tests. This paper takes into account a staged approach for the detector setup and for the delivered luminosity from the accelerator. The available detector setup at the time of the delivery of the first antiproton beams in the HESR storage ring is referred to as the Phase One setup. The physics programme that is achievable during Phase One is outlined in this paper.
The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is ...presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV2 and 18 × 275 GeV2. The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. The performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.
Abstract
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and ...momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity.
This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
Latest Technological Advances with MCP-PMTs Lehmann, A; Belias, A; Dzhygadlo, R ...
Journal of physics. Conference series,
11/2022, Letnik:
2374, Številka:
1
Journal Article
Recenzirano
Odprti dostop
This paper discusses the most recent advances with 2-inch MCP-PMTs. The status in terms of lifetime, detection efficiency, rate capability, time resolution, and gain behavior in magnetic fields are ...summarized. Significant progress in collection (CE) and quantum efficiency (QE) led to an excellent detection efficiency DQE = QE*CE of ∼30%. With a new DAQ setup up to several hundred anode pixels can be read out simultaneously in 3D allowing a glance “inside the PMT”. Parameters like dark count rates and ion afterpulsing are measurable as a function of the incident photon position as well as the temporal and spacial spread of recoil electrons and electronic and charge-sharing crosstalk even inside a magnetic field.
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar ...angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PMTs, started in 2018. In Sep. 2019 Nikon was selected to build the fused silica bars and successfully completed the series production of 112 bars in Feb. 2021. Measurements of the mechanical quality of the bars were performed by Nikon and the optical quality was evaluated at GSI. In Dec. 2020, the contract for the fabrication of the MCP-PMTs was awarded to PHOTONIS and the delivery of the first-of-series MCP-PMTs is expected in July 2021. We present the design of the PANDA Barrel DIRC as well as the status of the component series production and the result of the quality assurance measurements.
The antiproton experiment PANDA at FAIR is designed to bring hadron physics to a new level in terms of scope, precision and accuracy. In this work, its unique capability for studies of hyperons is ...outlined. We discuss ground-state hyperons as diagnostic tools to study non-perturbative aspects of the strong interaction, and fundamental symmetries. New simulation studies have been carried out for two benchmark hyperon-antihyperon production channels:
p
¯
p
→
Λ
¯
Λ
and
p
¯
p
→
Ξ
¯
+
Ξ
-
. The results, presented in detail in this paper, show that hyperon-antihyperon pairs from these reactions can be exclusively reconstructed with high efficiency and very low background contamination. In addition, the polarisation and spin correlations have been studied, exploiting the weak, self-analysing decay of hyperons and antihyperons. Two independent approaches to the finite efficiency have been applied and evaluated: one standard multidimensional efficiency correction approach, and one efficiency independent approach. The applicability of the latter was thoroughly evaluated for all channels, beam momenta and observables. The standard method yields good results in all cases, and shows that spin observables can be studied with high precision and accuracy already in the first phase of data taking with PANDA.
The GlueX experiment at Jefferson Laboratory aims to perform quantitative tests of non-perturbative QCD by studying the spectrum of light-quark mesons and baryons. A Detector of Internally Reflected ...Cherenkov light (DIRC) was installed to enhance the particle identification (PID) capability of the GlueX experiment by providing clean
π
/K separation up to 3.7 GeV/
c
momentum in the forward region (
θ
< 11°), which will allow the study of hybrid mesons decaying into kaon final states with significantly higher efficiency and purity. The new PID system is constructed with radiators from the decommissioned BaBar DIRC counter, combined with new compact photon cameras based on the SuperB FDIRC concept. The full system was successfully installed and commissioned with beam during 2019/2020. The initial PID performance of the system was evaluated and compared to one from Geant4 simulation.
.
Simulation results for future measurements of electromagnetic proton form factors at
P
¯
ANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the ...proton form factors can be determined is estimated. The signal channel
p
¯
p
→
e
+
e
-
is studied on the basis of two different but consistent procedures. The suppression of the main background channel,
i.e.
p
¯
p
→
π
+
π
-
, is studied. Furthermore, the background
versus
signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.
Abstract
PANDA (anti-proton annihiliation at Darmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion ...Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2 × 10
32
cm
−2
s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA disc DIRC detector that has not been used in any other high energy physics experiment before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees sufficient safety margins.