Colorectal cancer liver metastasis (CRLM) and hepatocellular carcinoma (HCC) are widely treated using microwave and radiofrequency ablation. Local tumor progression (LTP) may develop depending on the ...shortest vascular distance and large lesion diameter. This study aims to explore the effect of these spatial features and to investigate the correlation between tumor-specific variables and LTP.
This is a retrospective study covering the period between January 2007 and January 2019. One hundred twenty-five patients (CRLM: HCC: 64:61) with 262 lesions (CRLM: HCC: 142:120) were enrolled. The correlation between LTP and the variables was analyzed using the chi-square test, Fischer's exact test, or the Fisher-Freeman-Halton test where applicable. The local progression-free survival (Loc-PFS) was analyzed using the Kaplan-Meier method. Univariable and multivariable Cox regression analyses were performed to identify prognostic factors.
Significant correlations were observed for LTP in both CRLM and HCC at a lesion diameter of 30-50 mm (
= 0.019 and
< 0.001, respectively) and SVD of ≤3 mm (
< 0.001 for both). No correlation was found between the ablation type and LTP (CRLM:
= 0.141; HCC:
= 0.771). There was no relationship between residue and the ablation type, but a strong correlation with tumor size was observed (
= 0.127 and
< 0.001, respectively). In CRLM, LTP was associated with mutant K-ras and concomitant lung metastasis (
< 0.001 and
= 0.003, respectively). In HCC, a similar correlation was found for Child-Pugh B, serum alpha-fetoprotein (AFP) level of >10 ng/mL, predisposing factors, and moderate histopathological differentiation (
< 0.001,
= 0.008,
= 0.027, and
< 0.001, respectively). In CRLM, SVD of ≤3 mm proved to be the variable with the greatest negative effect on Loc-PFS (
= 0.007), followed by concomitant lung metastasis (
= 0.027). In HCC, a serum AFP level of >10 ng/mL proved to be the variable with the greatest negative effect on Loc-PFS (
= 0.045).
In addition to the lesions' spatial features, tumor-specific variables may also have an impact on LTP.
Capturing the surface mechanics of musculoskeletal extremities would enhance the realism of life-like mechanics imposed on the limbs within surgical simulations haptics. Other fields that rely on ...surface manipulation, such as garment or prosthetic design, would also benefit from characterization of tissue surface mechanics. Eight homogeneous tissue models were developed for the upper and lower legs and arms of two donors. Ultrasound indentation data was used to drive an inverse finite element analysis for individualized determination of region-specific material coefficients for the lumped tissue. A novel calibration strategy was implemented by using a ratio based adjustment of tissue properties from linear regression of model predicted and experimental responses. This strategy reduced requirement of simulations to an average of under four iterations. These free and open-source specimen-specific models can serve as templates for simulations focused on mechanical manipulations of limb surfaces.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The Reporting and Data System (RADS) has proven successful in various medical settings, but a standardized reporting system for abdominal emergencies is lacking. In this study, the Abdominal ...Emergency Reporting and Data System (AEM-RADS) for urgent findings on abdominal CT scans is introduced to address the need for consistency in emergency radiology.PURPOSEThe Reporting and Data System (RADS) has proven successful in various medical settings, but a standardized reporting system for abdominal emergencies is lacking. In this study, the Abdominal Emergency Reporting and Data System (AEM-RADS) for urgent findings on abdominal CT scans is introduced to address the need for consistency in emergency radiology.In this prospective observational study, conducted over a six-month period, the urgency of abdominal CT scans was assessed using the proposed AEM-RADS scoring system. The committee developed a scale ranging from AEM-RADS 1 (normal) to AEM-RADS 5 (urgent disease). Interobserver agreement between two observers with different experience was evaluated, and robust AEM-RADS reference values were established by radiologists who were not observers. Statistical analysis used mean, standard deviations and Kendall's tau analysis for interobserver agreement.METHODSIn this prospective observational study, conducted over a six-month period, the urgency of abdominal CT scans was assessed using the proposed AEM-RADS scoring system. The committee developed a scale ranging from AEM-RADS 1 (normal) to AEM-RADS 5 (urgent disease). Interobserver agreement between two observers with different experience was evaluated, and robust AEM-RADS reference values were established by radiologists who were not observers. Statistical analysis used mean, standard deviations and Kendall's tau analysis for interobserver agreement.Among 2656 patients who underwent CT for abdominal emergencies, the AEM-RADS distribution was 17.50% AEM-RADS 1, 28.57% AEM-RADS 2, 7.22% AEM-RADS 3, 35.61% AEM-RADS 4, and 11.06% AEM-RADS 5. Interobserver agreement was high, especially for urgent and emergent cases (p < 0.0001). Notable discrepancies were observed in AEM-RADS categories 2C-D and 3B-C, emphasizing the influence of radiologists' experience on interpretation. However, the interobserver agreement for both AEM-RADS 2C-D and 3B-C were statistically significant (p < 0.001).RESULTSAmong 2656 patients who underwent CT for abdominal emergencies, the AEM-RADS distribution was 17.50% AEM-RADS 1, 28.57% AEM-RADS 2, 7.22% AEM-RADS 3, 35.61% AEM-RADS 4, and 11.06% AEM-RADS 5. Interobserver agreement was high, especially for urgent and emergent cases (p < 0.0001). Notable discrepancies were observed in AEM-RADS categories 2C-D and 3B-C, emphasizing the influence of radiologists' experience on interpretation. However, the interobserver agreement for both AEM-RADS 2C-D and 3B-C were statistically significant (p < 0.001).AEM-RADS showed promising reliability, particularly in identifying urgent and emergent cases. Despite some inter-observer discrepancies, the system showed potential for standardized emergency workups. AEM-RADS could significantly enhance diagnostic accuracy in abdominal emergencies and provide a structured framework for shared decision-making between clinicians and radiologists.0.CONCLUSIONSAEM-RADS showed promising reliability, particularly in identifying urgent and emergent cases. Despite some inter-observer discrepancies, the system showed potential for standardized emergency workups. AEM-RADS could significantly enhance diagnostic accuracy in abdominal emergencies and provide a structured framework for shared decision-making between clinicians and radiologists.0.
Examination of all 24 ribs on axial computed tomography (CT) slices might become a leeway and rib fractures (RF) may easily overlook in daily practice. Rib unfolding (RU), a computer-assisted ...software, that promises rapid assessment of the ribs in a two-dimensional plan, was developed to facilitate rib evaluation. We aimed to evaluate the reliability and reproducibility of RU software for RF detection on CT and to determine the accelerating effect to determine any drawback of RU application.
Fifty-one patients with thoracic trauma formed the sample to be assessed by the observers. The characterization and distribution of RFs on CT images in this sample were recorded independently by the non-observers. Regarding the presence or ab-sence of RF, CT images were assessed blindedly by two radiologists with 5 years (observer-A) and 18 years (observer-B) of experience in thoracic radiology. Each observer assessed the axial CT and RU images on different days under non-observer supervision.
A total of 113 RFs were detected in 22 patients. The mean evaluation time for the axial CT images was 146.64 s for ob-server-A and 119.29 s for observer-B. The mean evaluation time for RU images was 66.44 s for observer-A and 32.66 s for observer-B. A statistically significant decrease was observed between the evaluation periods of observer-A and observer-B with RU software compared to the axial CT image assessment (p<0.001). The inter-observer κ value was 0.638, while the intra-observer results showed moderate (κ: 0.441) and good (κ: 0.752) reproducibility comparing the RU and axial CT assessments. Observer-A detected 47.05% non-displaced fractures, 48.93% minimally displaced (≤2 mm) fractures, and 38.77% displaced fractures on RU images (p=0.009). Ob-server-B detected 23.52% non-displaced fractures, 57.44% minimally displaced (≤2 mm) fractures, and 48.97% displaced fractures on RU images (p=0.045).
RU software accelerates fracture evaluation, while it has drawbacks including low sensitivity in fracture detection, false negativity, and underestimation of displacement.
Abstract Simulation-based medicine and the development of complex computer models of biological structures is becoming ubiquitous for advancing biomedical engineering and clinical research. Finite ...element analysis (FEA) has been widely used in the last few decades to understand and predict biomechanical phenomena. Modeling and simulation approaches in biomechanics are highly interdisciplinary, involving novice and skilled developers in all areas of biomedical engineering and biology. While recent advances in model development and simulation platforms offer a wide range of tools to investigators, the decision making process during modeling and simulation has become more opaque. Hence, reliability of such models used for medical decision making and for driving multiscale analysis comes into question. Establishing guidelines for model development and dissemination is a daunting task, particularly with the complex and convoluted models used in FEA. Nonetheless, if better reporting can be established, researchers will have a better understanding of a model's value and the potential for reusability through sharing will be bolstered. Thus, the goal of this document is to identify resources and considerate reporting parameters for FEA studies in biomechanics. These entail various levels of reporting parameters for model identification, model structure, simulation structure, verification, validation, and availability. While we recognize that it may not be possible to provide and detail all of the reporting considerations presented, it is possible to establish a level of confidence with selective use of these parameters. More detailed reporting, however, can establish an explicit outline of the decision-making process in simulation-based analysis for enhanced reproducibility, reusability, and sharing.
Emergent mechanics of musculoskeletal extremities (surface indentation stiffness and tissue deformation characteristics) depend on the underlying composition and mechanics of each soft tissue layer ...(i.e. skin, fat, and muscle). Limited experimental studies have been performed to explore the layer specific relationships that contribute to the surface indentation response. The goal of this study was to examine through statistical modeling how the soft tissue architecture contributed to the aggregate mechanical surface response across 8 different sites of the upper and lower extremities. A publicly available dataset was used to examine the relationship of soft tissue thickness (fat and muscle) to bulk tissue surface compliance. Models required only initial tissue layer thicknesses, making them usable in the future with only a static ultrasound image. Two physics inspired models (series of linear springs), which allowed reduced statistical representations (combined locations and location specific), were explored to determine the best predictability of surface compliance and later individual layer deformations. When considering the predictability of the experimental surface compliance, the physics inspired combined locations model showed an improvement over the location specific model (percent difference of 25.4 +/- 27.9% and 29.7 +/- 31.8% for the combined locations and location specific models, respectively). While the statistical models presented in this study show that tissue compliance relies on the individual layer thicknesses, it is clear that there are other variables that need to be accounted for to improve the model. In addition, the individual layer deformations of fat and muscle tissues can be predicted reasonably well with the physics inspired models, however additional parameters may improve the robustness of the model outcomes, specifically in regard to capturing subject specificity.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract Finite element analysis has been widely used in the field of foot and footwear biomechanics to determine plantar pressures as well as stresses and strains within soft tissue and footwear ...materials. When dealing with anatomical structures such as the foot, hexahedral mesh generation accounts for most of the model development time due to geometric complexities imposed by branching and embedded structures. Tetrahedral meshing, which can be more easily automated, has been the approach of choice to date in foot and footwear biomechanics. Here we use the nonlinear finite element program Abaqus (Simulia, Providence, RI) to examine the advantages and disadvantages of tetrahedral and hexahedral elements under compression and shear loading, material incompressibility, and frictional contact conditions, which are commonly seen in foot and footwear biomechanics. This study demonstrated that for a range of simulation conditions, hybrid hexahedral elements (Abaqus C3D8H) consistently performed well while hybrid linear tetrahedral elements (Abaqus C3D4H) performed poorly. On the other hand, enhanced quadratic tetrahedral elements with improved stress visualization (Abaqus C3D10I) performed as well as the hybrid hexahedral elements in terms of contact pressure and contact shear stress predictions. Although the enhanced quadratic tetrahedral element simulations were computationally expensive compared to hexahedral element simulations in both barefoot and footwear conditions, the enhanced quadratic tetrahedral element formulation seems to be very promising for foot and footwear applications as a result of decreased labor and expedited model development, all related to facilitated mesh generation.
The complexities of modern biomedicine are rapidly increasing. Thus, modeling and simulation have become increasingly important as a strategy to understand and predict the trajectory of ...pathophysiology, disease genesis, and disease spread in support of clinical and policy decisions. In such cases, inappropriate or ill-placed trust in the model and simulation outcomes may result in negative outcomes, and hence illustrate the need to formalize the execution and communication of modeling and simulation practices. Although verification and validation have been generally accepted as significant components of a model’s credibility, they cannot be assumed to equate to a holistic credible practice, which includes activities that can impact comprehension and in-depth examination inherent in the devel-opment and reuse of the models. For the past several years, the Committee on Credible Practice of Modeling and Simulation in Healthcare, an interdisciplinary group seeded from a U.S. interagency initiative, has worked to codify best practices. Here, we provide Ten Rules for credible practice of modeling and simulation in healthcare developed from a comparative analysis by the Committee’s multidisciplinary membership, followed by a large stakeholder com-munity survey. These rules establish a unified conceptual framework for modeling and simulation design, implementation, evaluation, dissemination and usage across the modeling and simulation life-cycle. While biomedical science and clinical care domains have somewhat different requirements and expectations for credible practice, our study converged on rules that would be useful across a broad swath of model types. In brief, the rules are: (1) Define context clearly. (2) Use contextually appropriate data. (3) Evaluate within context. (4) List limitations explicitly. (5) Use version control. (6) Document appropriately. (7) Disseminate broadly. (8) Get independent reviews. (9) Test competing imple-mentations. (10) Conform to standards. Although some of these are common sense guidelines, we have found that many are often missed or misconstrued, even by seasoned practitioners. Computational models are already widely used in basic science to generate new biomedical knowledge. As they penetrate clinical care and healthcare policy, contributing to personalized and precision medicine, clinical safety will require established guidelines for the credible practice of modeling and simulation in healthcare.
This study aimed to evaluate atrophy of the latissimus dorsi muscle (LDM) via computed tomography (CT) in patients who underwent mastectomy and axillary lymph node dissection (ALND). Secondary ...objectives were to investigate the relationship between the number of lymph nodes and muscle atrophy and to evaluate a possible correlation of muscle atrophy with the time interval between surgery and CT. The data of 125 patients who underwent unilateral modified radical mastectomy and ALND were reviewed retrospectively. The thickness and density of LDM were assessed using thorax computed tomography. The non-surgical side served as the control for each patient. The number of lymph nodes removed at ALND and the time from surgery to CT scan were also reported and evaluated for correlation with muscle atrophy. The mean thickness and density of the LDM were statistically significantly lower on the surgical side compared to the non-surgical side (
p
< 0.0001). The number of lymph nodes removed at ALND was negatively correlated with the thickness and density of LDM. The time interval between surgery and computed tomography was not correlated to either the thickness or density of LDM (p>0.05). The thickness and density of the LDM were seen to be decreased due to surgery although preservation of the nervus thoracodorsalis was defined in the surgery report. Intraoperative injury of the nerve during surgery may present more commonly than expected and affect muscle atrophy. In addition, the immobility of patients with breast cancer due to pain and swelling may also cause muscle atrophy.