Abstract
The barrel section of the novel MIP Timing Detector (MTD)
will be constructed as part of the upgrade of the CMS experiment to
provide a time resolution for single charged tracks in the range ...of
30–60 ps using LYSO:Ce crystal arrays read out with
Silicon Photomultipliers (SiPMs). A major challenge for the
operation of such a detector is the extremely high radiation level,
of about 2 × 10
14
1 MeV(Si) Eqv. n/cm
2
, that will be
integrated over a decade of operation of the High Luminosity Large
Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to
this level of radiation have shown a strong increase in dark count
rate and radiation damage effects that also impact their gain and
photon detection efficiency. For this reason during operations the
whole detector is cooled down to about -35°C. In this
paper we illustrate an innovative and cost-effective solution to
mitigate the impact of radiation damage on the timing performance of
the detector, by integrating small thermo-electric coolers (TECs) on
the back of the SiPM package. This additional feature, fully
integrated as part of the SiPM array, enables a further decrease in
operating temperature down to about -45°C. This leads to a
reduction by a factor of about two in the dark count rate without
requiring additional power budget, since the power required by the
TEC is almost entirely offset by a decrease in the power required
for the SiPM operation due to leakage current. In addition, the
operation of the TECs with reversed polarity during technical stops
of the accelerator can raise the temperature of the SiPMs up to
60°C (about 50°C higher than the rest of the
detector), thus accelerating the annealing of radiation damage
effects and partly recovering the SiPM performance.
Abstract
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce) is
one of the most widely used Cerium-doped Lutetium based
scintillation crystals. Initially developed for medical detectors it
...rapidly became attractive for High Energy Particle Physics (HEP)
applications, especially in the frame of high luminosity particle
colliders.
In this paper, a comprehensive and systematic study of LYSO:Ce
(Lu
(1-
x
)
Y
x
2
SiO
5
:Ce) crystals
is presented. It involves for the first time a large number of
crystal samples (180) of the same size from a dozen of producers.
The study consists of a comparative characterization of LYSO:Ce
crystal products available on the market by mechanical, optical and
scintillation measurements and aims specifically, to investigate key
parameters of timing applications for HEP.
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to ...their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic particles and to electromagnetic showers. Several prototypes, with different geometries and characteristics, were exposed to particle beams at the INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency are measured for single particles and as a function of the multiplicity of particles. Efficiencies between 50% and 90% to single relativistic particles are reached, and up to 100% in presence of a large number of particles. Time resolutions between 20 ps and 30 ps are obtained.
At the high luminosity LHC (HL-LHC) about 200 concurrent interactions are expected, with a spread between the interaction vertices of few centimeters in the beam direction and 200 ps in the collision ...time. A time of flight resolution of the order of 30 ps would be able to reduce neutral particles pile-up contamination at the calorimeter level of about one order of magnitude, restoring pile-up conditions similar to what is routinely sustained in the current run of the LHC . Micro-channel plates have been used in PMT configuration as fast charged particles detector (resolution of better than 20 ps have been achieved with commercial devices), however they are not particularly radiation tolerant, mostly due to the ion feedback on the photocathode. The possibility of using micro-channel plates without a photocathode (i-MCP) has been studied in several test beams. Different MCP geometries are compared with the goal to identify the optimal configuration. Efficiency of more then 70% with a time resolution of better than 40 ps are achieved for single charged particles, leading to an efficiency close to 100% for EM shower after few radiation lengths. This open the possibility to use i-MCPs as a timing layer in a sampling calorimeter or to use it in a pre-shower device independent from the calorimeter technology.
The High-Luminosity phase of the Large Hadron Collider at CERN (HL-LHC) poses stringent requirements on calorimeter performance in terms of resolution, pileup resilience and radiation hardness. A ...tungsten-CeF 3 sampling calorimeter is a possible option for the upgrade of current detectors. A prototype, read out with different types of wavelength-shifting fibers, has been built and exposed to high energy electrons, representative for the particle energy spectrum at HL-LHC, at the CERN SPS H4 beam line. This paper shows the performance of the prototype, mainly focussing on energy resolution and uniformity. A detailed simulation has been also developed in order to compare with data and to extrapolate to different configurations to be tested in future beam tests. Additional studies on the calorimeter and the R&D projects ongoing on the various components of the experimental setup will be also discussed.
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP ...surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.
I-MCP is an R&D project aimed at the exploitation of secondary emission of electrons from the surface of micro-channel plates (MCP) for single ionizing particles and fast timing of showers in high ...rate environments. Results from tests with electrons with energies up to 50GeV of MCP devices with different characteristics are presented. In particular detection efficiency and time resolution are measured for a range of MCP prototypes: different MCP channel diameter and layers configuration are studied. Devices operated in I-MCP configuration, where the particle detection proceed through direct ionization of the MCP layers, are studied in comparison with the more usual PMT-MCP configuration.
The results show efficiencies up to 70% for single charge particle detection for I-MCP devices with a time resolution of about 40ps. The efficiency raise to 100% in response to high energy electromagnetic showers.
A sampling calorimeter using cerium fluoride scintillating crystals as active material, interleaved with absorber plates made of tungsten, and read out by wavelength-shifting fibres has been tested ...with high-energy electron beams at the CERN SPS H4 beam line, as well as with lower-energy beams at the INFN Frascati Beam Test Facility in Italy. Energy resolution studies revealed a low stochastic term (<10%/E). This result, combined with high radiation hardness of the material used, marks this sampling calorimeter as a good candidate for the detectors׳ forward regions during the high luminosity phase of LHC.