INTRODUCTION AND OBJECTIVESThis article presents the annual activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) for the year 2022.METHODSAll ...Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company in collaboration with the members of the board of the ACI-SEC.RESULTSA total of 111 centers participated. The number of diagnostic studies increased by 4.8% compared with 2021, while that of percutaneous coronary interventions (PCI) remained stable. PCIs on the left main coronary artery increased by 22%. The radial approach continued to be preferred for PCI (94.9%). There was an upsurge in the use of drug-eluting balloons, as well as in intracoronary imaging techniques, which were used in 14.7% of PCIs. The use of pressure wires also increased (6.3% vs 2021) as did plaque modification techniques. Primary PCI continued to grow and was the most frequent treatment (97%) in ST-segment elevation myocardial infarction. Most noncoronary procedures maintained their upward trend, particularly percutaneous aortic valve implantation, atrial appendage closure, mitral/tricuspid edge-to-edge therapy, renal denervation, and percutaneous treatment of pulmonary arterial disease.CONCLUSIONSThe Spanish cardiac catheterization and coronary intervention registry for 2022 reveals a rise in the complexity of coronary disease, along with a notable growth in procedures for valvular and nonvalvular structural heart disease.
The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. ...This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX.
Prospective, multicenter, “real-world” registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center’s prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared.
359 patients mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9) were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed.
The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted.
Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural ...outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, “real-world” registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center’s prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9) were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted.
To estimate the prevalence of nonadherence to treatment and its relationship with social support and social context in patients with multimorbidity and polypharmacy followed-up in primary care. This ...was an observational, descriptive, cross-sectional, multicenter study with an analytical approach. A total of 593 patients between 65-74 years of age with multimorbidity (greater than or equal to3 diseases) and polypharmacy (greater than or equal to5 drugs) during the last three months and agreed to participate in the MULTIPAP Study. The main variable was adherence (Morisky-Green). The predictors were social support (structural support and functional support (DUFSS)); sociodemographic variables; indicators of urban objective vulnerability; health-related quality of life (EQ-5D-5L-VAS & QALY); and clinical variables. Descriptive, bivariate and multivariate analyses with logistic regression models and robust estimators were performed. Four out of ten patients were nonadherent, 47% had not completed primary education, 28.7% had an income less than or equal to1050 euro/month, 35% reported four or more IUVs, and the average perceived health-related quality of life (HRQOL) EQ-5D-5L-VAS was 65.5. The items that measure functional support, with significantly different means between nonadherent and adherent patients were receiving love and affection (-0.23; 95%CI: -0.40;-0.06), help when ill (-0.25; 95%CI: -0.42;-0.08), useful advice (-0.20; 95%CI: -0.37;-0.02), social invitations (-0.22; 95%CI:-0.44;-0.01), and recognition (-0.29; 95%CI:-0.50;-0.08). Factors associated with nonadherence were belonging to the medium vs. low tertile of functional support (0.62; 95%CI: 0.42;0.94), reporting less than four IUVs (0.69; 95%CI: 0.46;1.02) and higher HRQOL perception (0.98; 95%CI: 0.98;0.99). Among patients 65-74 years of age with multimorbidity and polypharmacy, lower functional support was related to nonadherence to treatment. The nonadherence decreased in those patients with higher functional support, lower urban vulnerability and higher perceived health status according to the visual analog scale of health-related quality of life.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK