Locking plates have threaded holes, in which threaded-head screws are affixed. Hence, they do not need to be in intimate contact with underlying bone to provide fixation. There are, however, reports ...that a large distance between the plate and the bone might cause clinical complications such as delayed union or nonunion, screw pull out, and screw and plate breakage. Considering the diversity in the capabilities and costs of different plate customization techniques, the purpose of this study was to investigate the effect of the plate contouring quality on the biomechanical performance of high tibial osteotomy (HTO) fixation. A finite element model of proximal tibia was developed in Abaqus, using the QCT data of a cadaver. The model was then subjected to open-wedge HTO (correction angle 12°) with TomoFix plate fixation. The sagittal curvature of the plate was changed parametrically to provide certain levels of geometrical fit, and the biomechanical performance parameters of fixation were assessed. Results indicated 5%, 9% and 38% increase in the stiffness of the construct, and the von Mises stress in the plate and locking screw just above the osteotomy site, respectively, when the level of fit of plate changed from 0% (initial non-contoured initial shape) to 100% (fully adapted shape). The same change decreased the pressure at the lateral hinge of the osteotomy by 61%, and the mean of the tensile stress on the screw shaft by 12%. It was concluded that the level of fit has conflicting effects on the biomechanical parameters of the HTO fixation system, that is, the structural stiffness, the pressure at the lateral hinge, the stresses in the plate and screws, and the pull out resistance of the screws. In particular, for HTO patients with high quality bone, the optimal level of fit should provide a tradeoff between these parameters.
In spite of the extensive literature on the analysis of the muscle synergies during gait, the functionality of these synergies has not been studied in detail. This study explored the relationship ...between the motor modules and the kinematic maneuvers involved in human walking. Motion and surface electromyography data (of 28 trunk and lower extremity muscles) were acquired from ten healthy subjects during ten trials of self-selected speed gait each. The joint angle trajectories were half-wave rectified and divided into two independent positive directional degrees-of-freedom. The muscle and kinematic synergies were both extracted using the non-negative matrix factorization (NNMF) technique and clustered via k-means method. Results indicated that for both the muscle and kinematic synergies, a same number of modules (five) could reconstruct the 200 limb-trial data reasonably well. Moreover, each individual muscle synergy was found to be associated with a single kinematic synergy, based on the similar activation periods of the paired muscle and kinematic modules and the high correlation of their activation patterns (r = 0.88 ± 0.05), with a consistent phase advance for muscle synergies (mean = 7.59 ± 2.34 %). It was concluded that there is a one-to-one association between the motor modules and kinematic synergies, suggesting that each individual kinematic synergy, representing a movement primitive of human walking, might be implemented by recruitment of a paired motor module.
This study presents a novel statistical volume element (SVE) for micromechanical modeling of the white matter structures, with histology-informed randomized distribution of axonal tracts within the ...extracellular matrix. The model was constructed based on the probability distribution functions obtained from the results of diffusion tensor imaging as well as the histological observations of scanning electron micrograph, at two structures of white matter susceptible to traumatic brain injury, i.e. corpus callosum and corona radiata. A simplistic representative volume element (RVE) with symmetrical arrangement of fully alligned axonal fibers was also created as a reference for comparison. A parametric study was conducted to find the optimum grid and edge size which ensured the periodicity and ergodicity of the SVE and RVE models. A multi-objective evolutionary optimization procedure was used to find the hyperelastic and viscoelastic material constants of the constituents, based on the experimentally reported responses of corpus callosum to axonal and transverse loadings. The optimal material properties were then used to predict the homogenized and localized responses of corpus callosum and corona radiata. The results indicated similar homogenized responses of the SVE and RVE under quasi-static extension, which were in good agreement with the experimental data. Under shear strain, however, the models exhibited different behaviors, with the SVE model showing much closer response to the experimental observations. Moreover, the SVE model displayed a significantly better agreement with the reports of the experiments at high strain rates. The results suggest that the randomized fiber architecture has a great influence on the validity of the micromechanical models of white matter, with a distinguished impact on the model’s response to shear deformation and high strain rates. Moreover, it can provide a more detailed presentation of the localized responses of the tissue substructures, including the stress concentrations around the low caliber axonal tracts, which is critical for studying the axonal injury mechanisms.
Background and aim
Gait and balance disorders are common in the elderly populations, and their prevalence increases with age. This systematic review was performed to summarize the current evidence ...for subthreshold vibration interventions on postural control and gait in elderly.
Method
A review of intervention studies including the following words in the title/abstract: insole, foot and ankle appliances, vibration, noise and elderly related to balance and gait. Databases searched included PubMed, ISI Web of Knowledge, Ovid, Scopus, and Google Scholar. Fifteen articles were selected for final evaluation. The procedure was followed using the preferred reporting items for systematic reviews and meta-analysis method.
Results
There was reduction in center of pressure velocity and displacement especially with eyes closed using vibration in healthy elderly subjects and this effect was greater in elderly faller and patients with more balance deficiency. Vibration programme training increased speed of walking, cadence, step time and length in stroke subjects. The vibratory insoles significantly improved performance on the Timed Up and Go and Functional Reach tests in older people.
Conclusion
Vibration was effective on balance improvement in elderly subject especially elderly with more balance deficiency and it can improve gait parameters in patients with greater baseline variability.
This study aims to 3D print titanium alloy constructs incorporating gradient of porosities, from the fully dense core to the porous outer surface. Gradient porous specimens were prepared using ...selective laser melting (SLM). Fully dense specimens fabricated by SLM were used as the control group. Characterization of samples was done using X-ray tomography, uniaxial compression testing, and optical and scanning electron microscopes. The biocompatibility of fabricated samples was investigated using human periodontal ligament stem cells via assessment of cell attachment, viability, and proliferation by direct and indirect assays. The data were analyzed using ANOVA and Tukey’s post hoc test. Characterization of constructs reveals interconnected gradient porosities and higher contact angle in porous samples. The introduction of porosity leads to a significant decrease in compression strength. However, Young’s modulus of the samples with gradient porosity was more similar to the natural bone modulus. The surface microstructure consists of loosely bonded spherical particles. Biocompatibility of the dense and porous samples is appropriate. Although the porosity size led to a reduced cell proliferation rate in the gradient sample, the extract of the gradient sample results in more cell proliferation than the dense sample’s extract. The study demonstrates that a biocompatible functionally graded porous titanium structure can be well fabricated by SLM, and this structure leads to a good match of Young’s modulus to that of the bone.
► Aseptic loosening of femoral component is associated with the deficiencies in engineering design. ► The main leading causes of loosening are wear behavior, bioactivity and mechanical properties. ► ...Functionally graded biomaterials have the potential to reduce the occurrence of leading causes.
Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs.
There are numerous functions for laser in modern implant dentistry including surface treatment, surface coating, and implant manufacturing. As laser application may potentially improve ...osseointegration of dental implants, we systematically reviewed the literature for in vitro biological responses to laser-modified or processed titanium dental implants. The literature was searched in PubMed, ISI Web, and Scopus, using keywords “titanium dental implants,” “laser,” “biocompatibility,” and their synonyms. After screening the 136 references obtained, 28 articles met the inclusion criteria. We found that Nd:YAG laser was the most commonly used lasers in the treatment or processing of titanium dental implants. Most of the experiments used cell attachment and cell proliferation to investigate bioresponses of the implants. The most commonly used cells in these assays were osteoblast-like cells. Only one study was conducted in stem cells. These in vitro studies reported higher biocompatibility in laser-modified titanium implants. It seems that laser radiation plays a vital role in cell response to dental implants; however, it is necessary to accomplish more studies using different laser types and parameters on various cells to offer a more conclusive result.
Purpose
Core Bone Plug Fixation (CBPF) technique is an implant-less methodology for ACL reconstruction. This study investigates the effect of bone density on CBPF stability to identify the bone ...quality that is likely to benefit from this technique.
Methods
Artificial blocks with 160 (Group 1), 240 (Group 2), and 320 (Group 3) kg/m
3
densities were used to simulate human bone with diverse qualities. These groups are representative of the elderly, middle age and young people, respectively. A tunnel was made in each test sample using a cannulated drill bit which enabled harvesting the core bone plug intact. Fresh animal tendon grafts were prepared and passed through the tunnel, so the core bone was pushed in to secure the tendon. The fixation stability was tested by applying a cyclic load following by a pullout load until the failure occurred. The selected group was compared with interference screw fixation technique as a gold standard method in ACL reconstruction.
Results
The Group 2 stiffness and yield strength were significantly larger than Group 1. The graft slippage of Group 1 was significantly less than Group 3. The ultimate strengths were 310 N and 363 N, in Groups 2 and 3, significantly larger than that of Group 1. The ultimate strength in fixation by interference screw was 693.18 N, significantly larger than the bone plug method.
Conclusions
The stability of CBPF was greatly affected by bone density. This technique is more suitable for young and middle-aged people. With further improvements, the CBPF might be an alternative ACL reconstruction technique for patients with good bone quality.
Clinical relevance
The CBPF technique offers an implant-less organic ACL reconstruction technique with numerous advantages and likely would speed up the healing process by using the patient’s own bones and tissues rather than any non-biologic fixations.
Purpose
Mass-spring-damper (MSD) models are often used for real-time surgery simulation due to their fast response and fairly realistic deformation replication. An improved real time simulation model ...of soft tissue deformation due to a laparoscopic surgical indenter was developed and tested.
Method
The mechanical realization of conventional MSD models was improved using nonlinear springs and nodal dampers, while their high computational efficiency was maintained using an adapted implicit integration algorithm. New practical algorithms for model parameter tuning, collision detection, and simulation were incorporated.
Results
The model was able to replicate complex biological soft tissue mechanical properties under large deformations, i.e., the nonlinear and viscoelastic behaviors. The simulated response of the model after tuning of its parameters to the experimental data of a deer liver sample, closely tracked the reference data with high correlation and maximum relative differences of less than 5 and 10%, for the tuning and testing data sets respectively. Finally, implementation of the proposed model and algorithms in a graphical environment resulted in a real-time simulation with update rates of 150 Hz for interactive deformation and haptic manipulation, and 30 Hz for visual rendering.
Conclusion
The proposed real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was efficient, realistic, and accurate in ex vivo testing. This model is a suitable candidate for testing in vivo during laparoscopic surgery.