Purpose To examine the outcomes of a breast cancer screening program based on digital breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography compared with those after full-field ...digital mammography (FFDM). Materials and Methods This prospective study included 16 666 asymptomatic women aged 50-69 years who were recruited in April 2015 through March 2016 for DBT plus synthetic 2D screening in the Verona screening program. A comparison cohort of women screened with FFDM (n = 14 423) in the previous year was included. Screening detection measures for the two groups were compared by calculating the proportions associated with each outcome, and the relative rates (RRs) were estimated with multivariate logistic regression. Results Cancer detection rate (CDR) for DBT plus synthetic 2D imaging was 9.30 per 1000 screening examinations versus 5.41 per 1000 screening examinations with FFDM (RR, 1.72; 95% confidence interval CI: 1.30, 2.29). CDR was significantly higher in patients screened with DBT plus synthetic 2D imaging than in those screened with FFDM among women classified as having low breast density (RR, 1.53; 95% CI: 1.13, 2.10) or high breast density (RR, 2.86; 95% CI: 1.42, 6.25). The positive predictive value (PPV) for recall was almost doubled with DBT plus synthetic 2D imaging: 23.3% versus 12.9% of recalled patients who were screened with FFDM (RR, 1.81; 95% CI: 1.34, 2.47). The recall rate was similar between groups (RR, 0.95; 95% CI: 0.84, 1.06), whereas the recall rate with invasive assessment was higher for DBT plus synthetic 2D imaging than for FFDM (RR, 1.93; 95% CI: 1.31, 2.03). The mean number of screening studies interpreted per hour was significantly lower for screening examinations performed with DBT plus synthetic 2D imaging (38.5 screens per hour) than with FFDM (60 screens per hour) (P < .001). Conclusion DBT plus synthetic 2D imaging increases CDRs with recall rates comparable to those of FFDM. DBT plus synthetic 2D imaging increased image reading time and the time needed for invasive assessments.
RSNA, 2017.
Colorectal cancer (CRC) screening programmes based on the guaiac faecal occult blood test (gFOBT) reduce CRC-specific mortality. Several studies have shown higher sensitivity with the faecal ...immunochemical test (FIT) compared with gFOBT. We carried out an ecological study to evaluate the impact of FIT-based screening programmes on CRC mortality.
In the Veneto Region (Italy), biennial FIT-based screening programmes that invited 50-69-year-old residents were introduced in different areas between 2002 and 2009. We compared CRC mortality rates from 1995 to 2011 between the areas where screening started in 2002-2004 (early screening areas (ESA)) and areas that introduced the screening in 2008-2009 (late screening areas (LSA)) using Poisson regression models. We also compared available data on CRC incidence rates (1995-2007) and surgical resection rates (2001-2012).
Before the introduction of screening, CRC mortality and incidence rates in the two areas were similar. Compared with 1995-2000, 2006-2011 mortality rates were 22% lower in the ESA than in the LSA (rate ratio (RR)=0.78; 95% CI 0.68 to 0.89). The reduction was larger in women (RR=0.64; CI 0.51 to 0.80) than in men (RR=0.87; CI 0.73 to 1.04). In the ESA, incidence and surgery rates peaked during the introduction of the screening programme and then returned to the baseline (2006-2007 incidence) or dropped below initial values (surgery after 2007).
FIT-based screening programmes were associated with a significant reduction in CRC mortality. This effect took place much earlier than reported by gFOBT-based trials and observational studies.
To assess variation in the main colonoscopy quality indicators in organised colorectal cancer (CRC) screening programmes based on faecal immunochemical test (FIT).
Data from a case-series of ...colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected. The adenoma detection rate (ADR) and caecal intubation rate (CIR) were assessed for the whole population and the individual endoscopists. To explore variation in the quality indicators, multilevel analyses were performed according to patient/centre/endoscopist characteristics.
We analysed 75 569 (mean age: 61.3 years; men: 57%) colonoscopies for positive FIT performed by 479 endoscopists in 79 centres. ADR ranged from 13.5% to 75% among endoscopists (mean: 44.8%). ADR was associated with gastroenterology specialty (OR: 0.87 for others, 95% CI 0.76 to 0.96) and, at the endoscopy centre level, with the routine use of sedation (OR: 0.80 if occasional (<33%); 95% CI 0.64 to 1.00) and availability of screening-dedicated sessions (OR: 1.35; 95% CI 1.11 to 1.66). CIR ranged between 58.8% and 100% (mean: 93.1%). Independent predictors of CIR at the endoscopist level were the yearly number of screening colonoscopies performed (OR: 1.51 for endoscopists with >600 colonoscopies; 95% CI 1.11 to 2.04) and, at the endoscopy centre level, screening-dedicated sessions (OR: 2.18; 95% CI 1.24 to 3.83) and higher rates of sedation (OR: 0.47 if occasional; 95% CI 0.24 to 0.92).
The quality of colonoscopy was affected by patient-related, endoscopist-related and centre-related characteristics. Policies addressing organisational issues should improve the quality of colonoscopy in our programme and similar programmes.
To assess detection rate and predictive factors of sessile serrated polyps (SSPs) in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT).
Data from a ...case series of colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected, including the age-standardised and sex-standardised adenoma detection rate (ADR) of the individual endoscopists. The SSP detection rate (SSP-DR) was assessed for the study population. To identify SSP-predictive factors, multilevel analyses were performed according to patient/centre/endoscopist characteristics.
We analysed 72 021 colonoscopies, of which 1295 presented with at least one SSP (SSP-DR 1.8%; 95% CI 1.7% to 1.9%). At the
level, SSP-DR was associated with males (OR 1.35; 95% CI 1.17 to 1.54) and caecal intubation (OR 3.75; 95% CI 2.22 to 6.34), but not with the FIT round. The presence of at least one advanced adenoma was more frequent among subjects with SSPs than those without (OR 2.08; 95% CI 1.86 to 2.33). At the
level, SSP-DR was associated with ADR (third vs first ADR quartile: OR 1.55; 95% CI 1.03 to 2.35; fourth vs first quartile: OR 1.89; 95% CI 1.24 to 2.90).
The low prevalence of SSPs and the lack of association with the FIT round argue against SSP as a suitable target for FIT-based organised programmes. Strict association of SSP-DR with the key colonoscopy quality indicators, namely caecal intubation rate and high ADR further marginalises the need for SSP-specific quality indicators in FIT-based programmes.
HPV DNA-based screening is more effective than a Pap test in preventing cervical cancer, but the test is less specific. New HPV tests have been proposed for primary screening. The HPV mRNA test ...showed a similar or slightly lower sensitivity than the HPV DNA tests but with a higher specificity. We report the results of an organised HPV mRNA-based screening pilot program in Venice, Italy.
From October 2011 to May 2014, women aged 25-64 years were invited to undergo a HPV mRNA test (Aptima). Those testing positive underwent cytological triage. Women with positive cytology were referred to colposcopy, whereas those with negative cytology were referred to repeat the HPV mRNA test 1 year later. The results of the HPV mRNA test program were compared with both the local historical cytology-based program and with four neighbouring DNA HPV-based pilot projects.
Overall, 23 211 women underwent a HPV mRNA test. The age-standardised positivity rate was 7.0%, higher than in HPV DNA programs (6.8%; relative rate (RR) 1.11, 95% confidence interval (CI) 1.05-1.17). The total colposcopy referral was 5.1%, double than with cytology (2.6%; RR 2.02, 95% CI 1.82-2.25) but similar to the HPV DNA programs (4.8%; RR 1.02; 95% CI 0.96-1.08). The cervical intraepithelial neoplasia grade 2+ detection rate with HPV mRNA was greater than in the HPV DNA programs at baseline (RR 1.50; 95% CI 1.19-1.88) and not significantly lower at the 1-year repeat (RR 0.70; 95% CI 0.40-1.16). The overall RR was 1.29 (95% CI 1.05-1.59), which was much higher than with cytology (detection rate 5.5‰ vs 2.1‰; RR 2.50, 95% CI 1.76-3.62).
A screening programme based on the HPV mRNA obtained results similar to those observed with the HPV DNA test. In routine screening programmes, even a limited increase in HPV prevalence may conceal the advantage represented by the higher specificity of HPV mRNA.
Although guaiac-based faecal occult blood test screening has been shown to be effective in reducing colorectal cancer (CRC) mortality, it has been criticised mostly for its low sensitivity. Italian ...CRC screening programmes are based on immunochemical tests (iFOBT). We collected and analysed the interval cancers (ICs) found by five screening programmes to estimate their sensitivity.
ICs were identified in subjects who had a negative result in a screening examination from 2002 to 2007 (N=267,789); data were linked with 2002-2008 hospital discharge records. Analysis was based on the follow up of 468,306 person-years. The proportional incidence-based sensitivity was estimated overall and by sex, age class, time since last negative iFOBT result, anatomical site, and history of screening (first or subsequent test).
Overall, 126 ICs were identified, compared to 572 expected cancers. The proportional incidences were 15.3% and 31.0% in the first and the second interval-years, respectively, with an overall episode sensitivity of 78.0% (95% CI: 73.8 to 81.6). Sensitivity was higher for males than females (80.1% vs 74.8%); no differences were observed by age, anatomical site or between programmes. The test sensitivity of iFOBT was 82.1% (95% CI 78.1% to 85.3%).
iFOBT-based screening programmes showed a high performance in terms of sensitivity as estimated through the IC rates. The screening schedule utilised in our programmes (single iFOBT, positivity threshold of 100 ng Hb/ml of sample solution, inter-screening interval of 2 years) shows low rates of missed cancers that are diagnosed during the interval. HDR are a convenient and reliable source of data for IC studies.
To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT).
74 Italian CRC ...screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013.
49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05).
In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third.