A scintillating bolometer based on a large cubic Li2100MoO4 crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground ...laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation 0ν2β experiment CUPID . The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li2100MoO4 bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV γ line. The detection of scintillation light for each event triggered by the Li2100MoO4 bolometer allowed for a full separation (∼8σ) between γ(β) and α events above 2 MeV . The Li2100MoO4 crystal also shows a high internal radiopurity with 228Th and 226Ra activities of less than 3 and 8 μBq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li2100MoO4 scintillating bolometers for high-sensitivity searches for the 100Mo 0ν2β decay in CROSS and CUPID projects.
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground ...Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses <10 GeV/c2. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eVee (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ∼9 eVee at 0 keV to 101 eVee at ∼10 keVee. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/c2. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses ≲3 GeV/c2.
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a ...second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σe is constrained for dark matter masses from 0.5 to 104 MeV / c2; in the mass range from 1.2 to 50 eV / c2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant gae are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σe = 8.7 × 10−34 cm2, ϵ = 3.3 × 10−14, and gae = 1.0 × 10−9.
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤10 GeV/c2) that may constitute dark matter by using cryogenic detectors of two types ...(HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ∼1×10−43 cm2 for a dark matter particle mass of 1 GeV/c2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H3 and naturally occurring Si32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has ...achieved a low energy threshold with improved sensitivity to low-mass ( < 10 GeV / c 2 ) dark matter particles. We present an analysis of the final CDMSlite dataset, taken with a different detector than was used for the two previous CDMSlite datasets. This analysis includes a data “salting” method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV / c 2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4 × 10 − 42 cm 2 at 5 GeV / c 2 , a factor of ~ 2.5 improvement over the previous CDMSlite result.
Micro-X is a NASA-funded, sounding rocket-borne X-ray imaging spectrometer that will allow high precision measurements of velocity structure, ionization state and elemental composition of extended ...astrophysical systems. One of the biggest challenges in payload design is to maintain the temperature of the detectors during launch. There are several vibration damping stages to prevent energy transmission from the rocket skin to the detector stage, which causes heating during launch. Each stage should be more rigid than the outer stages to achieve vibrational isolation. We describe a major design effort to tune the resonance frequencies of these vibration isolation stages to reduce heating problems prior to the projected launch in the summer of 2014.
Superconducting transition-edge sensor (TES) microcalorimeters have demonstrated the Constellation-X requirements for spectral resolution, speed, and pixel size in a close-packed geometry. We will ...present our recent breakthrough energy resolution with sensors that have all gold and bismuth-gold absorbers. This has been enabled by cantilevered absorbers that make contact to the TES only in regions that are not part of the active thermometer. With this approach, rapid thermalization of the x-ray energy is achieved and interaction between the absorber and TES sensor films is avoided. This design allows us to obtain uniform high performance and is compatible with large-format, high fill-factor arrays. We will discuss this design, the results we have achieved in 8×8 arrays of these pixels, and the dependence of the performance on the geometry of the absorber contact area and on stress within the sensor.
Understanding the response of dark matter detectors at the lowest recoil energies is important for correctly interpreting data from current experiments or predicting the sensitivity of future ...experiments to low mass weakly interacting massive particles. In particular, the ionization yield is essential for determining the correct recoil energy of candidate nuclear recoil events; however, few measurements in cryogenic crystals exist below 1 keV. Using the voltage-assisted calorimetric ionization detection technique with a mono-energetic neutron source, we show that it is possible to determine the ionization yield in cryogenic crystals down to an energy to 100 eV. This measurement will also determine the statistics of ionization production at these low energies.
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of ...axionlike particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/c2to 500 keV/c2for both candidates, excluding previously untested parameter space for masses below ∼ 1 keV/c2. For the kinetic mixing of dark photons, values below 10−15 are reached for particle masses around 100 eV/c2; for the axioelectric coupling of axionlike particles, values below 10−12 are reached for particles with masses in the range of a few-hundred eV/c2.