Abstract Objectives The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. Methods Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. Results All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. Conclusions TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.
Abstract Objectives The aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background BPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety. Methods The ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure. Results Among 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio HR: 1.33, 95% confidence interval CI: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815). Conclusions This large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.
Although transcatheter aortic valve implantation (TAVI) is still currently guided by transesophageal echocardiography (TEE) in a considerable number of hospitals, exclusive angiographic (Angio) ...guidance seems a reasonable approach in this setting. To date, however, no studies have directly compared the outcomes of TAVI according to the imaging modality used for procedural guidance. We, therefore, used data from a large multicenter data repository to compare the outcomes of TAVI guided exclusively by Angio and ATEE. All consecutive patients with severe aortic stenosis who underwent TAVI with the CoreValve Revalving System (CRS) in 9 Italian centers from September 2007 to March 2014, dichotomized according to the imaging support used to guide the procedure (ATEE and Angio), were included. Thirty-day and 12-month clinical outcomes were evaluated. Propensity matching analysis was performed to adjust for baseline differences. A total of 625 patients were included (256 and 369 patients were included in the ATEE and Angio groups, respectively). Patients from the ATEE more frequently underwent TAVI under general anesthesia compared with Angio group (37.9% vs 22.8%, respectively, p <0.001). Importantly, ∼80% of the patients experienced mild or even less aortic regurgitation as assessed by angiography after the procedure, without between-group differences. Postdilation and valve-in-valve rates were equivalent (24.7% vs 25%, p = 0.934 and 5.5% vs 3.4%, respectively, p = 0.217). No differences were revealed in the rates of death, cardiovascular death, and stroke or transient ischemic attack at 12-month follow-up. These results were sustained after propensity matching analysis. In conclusion, as long as a comprehensive procedural planning is performed, TAVI with CRS may be performed exclusively under angiographic guidance without the need for associated TEE.
The aim of this study was to investigate the effects of transcatheter aortic valve implantation (TAVI) on left ventricular (LV) hypertrophy and diastolic function in patients with severe aortic valve ...stenosis (AVS). There are few and conflicting data on LV mass remodeling and LV diastolic function after TAVI.
Echocardiography and clinical assessment were performed at baseline and at 6 months in high-risk patients affected by severe AVS who underwent TAVI.
One hundred thirty-five patients successfully underwent TAVI. Peak transvalvular aortic pressure gradient and mean transvalvular aortic pressure gradient were reduced from 87 ± 25 to 18 ± 7 mm Hg and from 54 ± 14 to 9 ± 4 mm Hg, respectively (P < .001), accompanied by significant clinical improvement. The mean LV ejection fraction improved from 50 ± 13% to 54 ± 11% during follow-up (P = .009). At 6-month follow-up, interventricular septal wall thickness regressed from 14 ± 2 to 12 ± 1 mm and posterior wall thickness from 13 ± 3 to 11 ± 2 mm (P < .001). LV mass and LV mass index decreased from 332 ± 106 to 228 ± 58 g (P < .001) and from 191 ± 58 to 132 ± 30 g/m(2) (P < .001), respectively. Ninety-seven patients (72%) showed improvements in LV diastolic filling pattern. The mean e' value increased from 4.1 ± 1.7 to 5.6 ± 2.2 cm/sec, and the mean E/e' ratio decreased from 24 ± 7 to 17 ± 6 (P < .001) after TAVI.
Significant LV mass reverse remodeling associated with improvement in LV systolic and diastolic function was found in patients with severe AVS 6 months after TAVI. These changes may have relevant clinical prognostic value.
Reoperation was reported in 2 cases: a 60-year-old woman with severely impaired left ventricular function underwent cardiac transplantation and concomitant CV prosthesis removal, and a 30-year-old ...man with pre-existing mitral prosthesis dysfunction and residual moderate or severe perivalvular leak after TAVI underwent combined surgical aortic and mitral replacement with mechanical prostheses 2 months after TAVI, after the clinical and hemodynamic conditions improved, to allow a surgical approach. ...a minimum significant reduction in mean systolic pulmonary arterial pressure was reported (from 49.5 ± 15.6 mm Hg to 43.4 ± 10.2 mm Hg, p = 0.032).
Identified sources of bacteremia were iatrogenic (n = 3), recurrent bacteremia from systemic infections (n = 2), and systemic diseases (n = 4) (Osler-Weber-Rendu disease, colon cancer, advanced liver ...cirrhosis with previous IE, and advanced liver cirrhosis with drug-induced immune suppression). ...despite timely and aggressive management, TAVR-PIE is associated with a very high mortality.
Abstract Scarce data are available on the impact of age on transcatheter aortic valve implantation (TAVI) outcomes. We, therefore, analyzed 1845 consecutive patients from 9 Italian centers who ...underwent TAVI with the CoreValve Revalving System (CRS) from September 2007 to March 2014; patients were dichotomized according to their age in the date of the procedure, as follows: 75-85 years-old and > 85 years-old. End points were defined according to Valve Academic Research Consortium definitions. In-hospital, 30-day, and 1-year clinical and echocardiographic data were available for 100% of the patients included. Propensity matching was performed. Procedural success rates were high (>94%) and comparable between groups. While worse baseline renal function was observed in the older group, the incidence of acute kidney injury (AKI) post-procedure was comparable (17.1% and 17.4%, respectively for the 75-85- and > 85-years-old group, p = 0.877); importantly, > 99% of AKI episodes in both groups were grades 1 and 2. Procedural complications rates were low without between-group differences. In-hospital death (3.7% and 4.6%, p = 0.379) and stroke/transient ischemic attack (TIA) (1.9% and 1.9%, respectively, p = 0.960) were comparable. The 1-year death rates were 14.9% and 17.2% (p = 0.197) in the 75-85- and >85-years-old group, respectively. Cardiovascular death was observed in 7.8% and 7% (p = 0.542), while stroke/TIA was demonstrated in 5.2% and 4.4% (p = 0.496), respectively. Results were sustained after propensity matching. In conclusion, advanced age did not negatively impact the outcomes of TAVI through 1-year post procedure.