We present the MIGA experiment, an underground long baseline atom interferometer to study gravity at large scale. The hybrid atom-laser antenna will use several atom interferometers simultaneously ...interrogated by the resonant mode of an optical cavity. The instrument will be a demonstrator for gravitational wave detection in a frequency band (100 mHz-1 Hz) not explored by classical ground and space-based observatories, and interesting for potential astrophysical sources. In the initial instrument configuration, standard atom interferometry techniques will be adopted, which will bring to a peak strain sensitivity of Formula: see text at 2 Hz. This demonstrator will enable to study the techniques to push further the sensitivity for the future development of gravitational wave detectors based on large scale atom interferometers. The experiment will be realized at the underground facility of the Laboratoire Souterrain à Bas Bruit (LSBB) in Rustrel-France, an exceptional site located away from major anthropogenic disturbances and showing very low background noise. In the following, we present the measurement principle of an in-cavity atom interferometer, derive the method for Gravitational Wave signal extraction from the antenna and determine the expected strain sensitivity. We then detail the functioning of the different systems of the antenna and describe the properties of the installation site.
Achieving the demanding sensitivity and bandwidth, envisaged for third-generation gravitational wave (GW) observatories, is extremely challenging with a single broadband interferometer. Very high ...optical powers (megawatts) are required to reduce the quantum noise contribution at high frequencies, while the interferometer mirrors have to be cooled to cryogenic temperatures in order to reduce thermal noise sources at low frequencies. To resolve this potential conflict of cryogenic test masses with high thermal load, we present a conceptual design for a 2-band xylophone configuration for a third-generation GW observatory, composed of a high-power, high-frequency interferometer and a cryogenic low-power, low-frequency instrument. Featuring inspiral ranges of 3200 Mpc and 38 000 Mpc for binary neutron stars and binary black holes coalesences, respectively, we find that the potential sensitivity of xylophone configurations can be significantly wider and better than what is possible in a single broadband interferometer.
We present a compact, fibre-coupled interferometer with high sensitivity and a large working range. We propose to use this interferometer as a readout mechanism for future inertial sensors, removing ...a major limiting noise source, and in precision positioning systems. The interferometer's peak sensitivity is 2×10−14 m Hz−1 at 70 Hz and 7×10−11 m Hz−1 at 10 mHz. If deployed on a GS-13 geophone, the resulting inertial sensing output will be limited by the suspension thermal noise of the reference mass from 10 mHz to 2 Hz.
Atom interferometers (AIs) are promising tools for precision measurement with applications ranging from geophysical exploration and tests of the equivalence principle of general relativity to the ...detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs, and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an AI operates, simultaneous fluorescence detection with a charge-coupled device sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration required for reaching the atom shot noise limit.
An accurate readout of low-power optical higher-order spatial modes is of increasing importance to the precision metrology community. Mode sensors are used to prevent mode mismatches from degrading ...quantum and thermal noise mitigation strategies. Direct mode analysis sensors (MODAN) are a promising technology for real-time monitoring of arbitrary higher-order modes. We demonstrate MODAN with photo-diode readout to mitigate the typically low dynamic range of CCDs. We look for asymmetries in the response of our sensor to break degeneracies in the relative alignment of the MODAN and photo-diode and consequently improve the dynamic range of the mode sensor. We provide a tolerance analysis and show methodology that can be applied for sensors beyond first order spatial modes.
We have developed, produced and characterized integrated sensors, actuators and the related read-out and drive electronics that will be used for the control of the Advanced LIGO suspensions. The ...overall system consists of the BOSEMs (a displacement sensor with an integrated electromagnetic actuator), the satellite boxes (the BOSEM readout and interface electronics) and six different types of coil-driver units. In this paper, we present the design of this read-out and control system, we discuss the related performance relevant for the Advanced LIGO suspensions, and we report on the experimental activity finalized at the production of the instruments for the Advanced LIGO detectors.
We have investigated the generation of highly pure higher-order Laguerre-Gauss (LG) beams at high laser power of order 100 W, the same regime that will be used by second-generation gravitational wave ...interferometers such as Advanced LIGO. We report on the generation of a helical-type LG33 mode with a purity of order 97% at a power of 83 W, the highest power ever reported in literature for a higher-order LG mode. This is a fundamental step in proving technical readiness for use of LG beams in gravitational wave interferometers of future generations.
Abstract
So far, the sensitivity of gravitational-wave (GW) detectors, in the low-frequency and mid-frequency regions of its bandwidth, has been limited by technical noises. The re-injection of ...sensing and control noises can be one of the main limitations. After the end of the third observing run O3, in preparation for the fourth observing run O4, an upgrade phase started among all the km-scale GW detectors, namely LIGO, Virgo and KAGRA, with the aim of improving their sensitivity. In particular, for the case of Advanced Virgo, one of the most significant upgrades is the installation of a signal recycling (SR) mirror, introducing the SR cavity. The main target of this SR mirror is to shape the sensitivity curve of the detector. The installation of a SR mirror adds an extra optical cavity and, thus, extra DoFs (longitudinal and angular), that should be controlled to keep its working point, ultimately increasing the complexity of the whole control strategy. In order to have an accurate description of the interferometer, we have implemented a multiple-input multiple-output (MIMO) model in the frequency domain. The target of this paper, after showing the Advanced Virgo configuration for the next observing run, is to describe the control scheme used for the main longitudinal degrees of freedom using a MIMO approach. In particular, we detail a useful matrix representation for the modeled system. Finally, we use the implemented model to project the sensing and control noises on the sensitivity curve. Following the obtained results, we propose noise subtraction filters to achieve the low control noise target in the low-frequency region of the sensitivity curve. Additionally, using this model, we have implemented the core of a noise budget tool, which will allow to estimate the contribution of all the known sources of noise on the measured sensitivity.
The upcoming European design study 'Einstein gravitational-wave Telescope' represents the first step towards a substantial, international effort for the design of a third-generation interferometric ...gravitational wave detector. It is generally believed that third-generation instruments might not be installed into existing infrastructures but will provoke a new search for optimal detector sites. Consequently, the detector design could be subject to fewer constraints than the on-going design of the second-generation instruments. In particular, it will be prudent to investigate alternatives to the traditional L-shaped Michelson interferometer. In this paper, we review an old proposal to use three Michelson interferometers in a triangular configuration. We use this example of a triple Michelson interferometer to clarify the terminology and will put this idea into the context of more recent research on interferometer technologies. Furthermore, the benefits of a triangular detector will be used to motivate this design as a good starting point for a more detailed research effort towards a third-generation gravitational-wave detector.