Hyperextension orthoses (HOs) for nonoperative treatment of osteoporotic vertebral fractures (OVFs) are widely prescribed. However, the compliance, how much an HO is worn after it has been ...prescribed, is widely unknown.
This study was performed to assess the wearing time of HOs for OVFs in a prospective blinded, sensor-controlled manner.
A prospective, single blinded observational study was performed.
This study prospectively included 18 patients who were treated nonoperatively with an HO for OVFs.
The true wearing time was measured using a hidden temperature-based sensor. The patients were invited to return for regular follow-up every 2 weeks for 6 weeks, at which time clinical evaluation (including a visual analog scale for pain and the Oswestry disability questionnaire) and radiographs of the spine were performed.
Full compliance was defined as a wearing time of 15 hours per day. Correlation between compliance and demographic differences, patient reported outcomes and radiographic changes of the vertebral structures were calculated.
The mean HO wearing time was 5.5±3.3 hours (37%±22% compliance). Female patients used the HO significantly longer per day than did male patients (6.5±3.2 vs 2.9±2.0 hours, p=.039). Age and body mass index had no influence on wearing behavior.
Overall, compliance with wearing HOs is poor and shows great variability with significant gender-dependency but not associated with BMI, age, or pain-level. Further studies are required to confirm our results that the wearing time does not have an influence on kyphotic progression of the osteoporotic fractured segment, nor on clinical outcome at short term.
I
Purpose
The present study compared patients developing ASD after L4/5 spinal fusion with a control group using a patient-specific statistical shape model (SSM) to find alignment-differences between ...the groups.
Methods
This study included patients who had undergone spinal fusion at L4/5 and either remained asymptomatic (control group;
n
= 25, follow-up of > 4 years) or required revision surgery for epifusional ASD (
n
= 22). Landmarks on preoperative and postoperative lateral radiographs were annotated, and the optimal spinal sagittal alignment was calculated for each patient. The two-dimensional distance from the SSM-calculated optimum to the actual positions before and after fusion surgery was compared.
Results
Postoperatively, the additive mean distance from the SSM-calculated optimum was 86.8 mm in the ASD group and 67.7 mm in the control group (
p
= 0.119). Greater differences were observed between the groups with a larger distance to the ideal in patients with ASD at more cranial levels. Significant difference between the groups was seen postoperatively in the vertical distance of the operated segment L4. The patients with ASD (5.69 ± 3.0 mm) had a significant greater distance from the SSM as the control group (3.58 ± 3.5 mm,
p
= 0.034).
Conclusion
Patients with ASD requiring revision after lumbar spinal fusion have greater differences from the optimal spinal sagittal alignment as an asymptomatic control group calculated by patient-specific statistical shape modeling. Further research might help to understand the value of SSM, in conjunction with already established indexes, for preoperative planning with the aim of reducing the risk of ASD.
Level of evidence I
Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding
Leishmaniasis are diseases caused by parasites belonging to
genus. The treatment with pentavalent antimonials present high toxicity. Secondary line drugs, such as amphotericin B and miltefosine also ...have a narrow therapeutic index. Therefore, there is an urgent need to develop new drugs to treat leishmaniasis. Here, we present the in vitro anti-leishmanial activity of unusual dimeric flavonoids purified from
. Three compounds were tested against
sp. Compound 2 was the most active against promastigotes. Quantifying the in vitro infected macrophages revealed that compound 2 was also the most active against intracellular amastigotes of
, without displaying host cell toxicity. Drug combinations presented an additive effect, suggesting the absence of interaction between amphotericin B and compound 2. Amastigotes treated with compound 2 demonstrated alterations in the Golgi and accumulation of vesicles inside the flagellar pocket. Compound 2-treated amastigotes presented a high accumulation of cytoplasmic vesicles and a myelin-like structure. When administered in
-infected mice, neither the oral nor the topical treatments were effective against the parasite. Based on the high in vitro activity, dimeric flavonoids can be used as a lead structure for the development of new molecules that could be useful for structure-active studies against
.
A retrospective, single center, data analysis.
Persistent pain and instability are common complications after distal ulnar head arthroplasty. One main reason may be the insufficient representation of ...the anatomical structures with the prosthesis. Some anatomical structures are neglected such as the ulnar head offset and the ulnar torsion which consequently influences the wrist biomechanics.
CT scans of the ulnae of forty healthy and asymptomatic patients were analyzed in a three-dimensional surface calculation program. In the best fit principle, cylinders were fitted into the medullary canal of the distal ulna and the ulnar head to determine their size. The distance between the central axes of the two cylinders was measured, which corresponds to the ulnar offset, and also their rotational orientation was measured, which corresponds to the ulnar torsion.
The mean medullary canal diameter was 5.8 mm (±0.8), and the ulnar head diameter was 15.8 mm (±1.5). The distance between the two cylinder axes was 3.89 mm (±0.78). The orientation of this offset was at an average of 8.63° (±15.28) of supination, reaching from 23° pronation to 32° supination.
With these findings, a novel ulnar head prosthesis should have different available stem and head sizes but also have an existing but variable offset between these two elements. A preoperative three-dimensional analysis is due to the high variation of offset orientation highly recommended. These findings might help to better represent the patients natural wrist anatomy in the case of an ulnar head arthroplasty.
III.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
A rotator cuff tear (RCT) is a common shoulder diagnosis and its etiology may be acute, traumatic, or chronic degenerative. Differentiation between the 2 etiologies may be important for multiple ...reasons, but remains difficult based on imaging. Further knowledge about radiographic and magnetic resonance findings to distinguish traumatic from degenerative RCT is needed.
We analyzed magnetic resonance arthrograms (MRAs) of 96 patients with traumatic or degenerative superior RCT, which were matched according their age and the affected rotator cuff muscle into the 2 groups. Patients older than 66 years of age were excluded from the study to avoid including cases with pre-existing degeneration. In the case of traumatic RCT, the time between the trauma and MRA had to be less than 3 months. Various parameters of the supraspinatus (SSP) muscle-tendon unit were assessed (tendon thickness, presence of a remaining tendon stump at the greater tubercle, magnitude of retraction, layer appearance). The retraction of the 2 SSP layers were individually measured to determine the difference of retraction. Additionally, edema of the tendon and muscle, the tangent- and kinking-sign as well as the newly introduced Cobra-sign (bulging of the distal part of the ruptured tendon with slim configuration of the medial part of the tendon) were analyzed.
Edema within the SSP muscle (sensitivity 13%, specificity 100%, P = .011) or the tendon (sensitivity 86%, specificity 36%, P = .014) are more frequent in traumatic RCT. The same association was found for the kinking-sign (sensitivity 53%, specificity 71%, P = .018) and the Cobra sign (sensitivity 47%, specificity 84%, P = .001). Even though not statistically significant, tendencies were observed toward thicker tendon stumps in traumatic RCT, and greater difference in retraction between the 2 SSP layers in the degenerative group. The cohorts had no difference in the presence of a tendon stump at the greater tuberosity.
Muscle and tendon edema, as well as tendon kinking appearance and the newly introduced cobra-sign are suitable MRA parameters to distinguish between traumatic and degenerative etiology of a superior RTC.
Abstract
Background
Intra-articular malunions of the finger can lead to deformity and loss of function and can be treated with intra-articular corrective osteotomies. The aim of this study was to ...evaluate radiographic joint congruency, feasibility and functional outcome of three-dimensional (3D) printed patient-specific instrumentation (PSI) for corrective osteotomies at the trapeziometacarpal and finger joints.
Methods
Computer-tomography (CT) scans were acquired preoperatively for standard 3D planning, which was followed by calculation of cutting planes and the design of individualized bone surface contact drilling, sawing and reposition guides. Follow-up CT scans and clinical examinations (range of motion, grip strength) were performed. Postoperative complications were documented and patient-reported outcome measurements were assessed (Single Assessment Numeric Evaluation (SANE) score, brief Michigan Hand Questionnaire (MHQ)).
Results
Ten patients (mean age 28.4 ± 12.8,range 13.8–51.3) years) were included with a mean follow-up of 21 ± 18 (3–59) months including seven osteotomies at the trapeziometacarpal or metacarpophalangeal joints and three at the proximal interphalangeal joint (PIP). All radiographic follow-up examinations showed the planned correction with good joint congruency and regular osseous consolidation. At the latest follow-up, the range of motion (ROM) increased and the average grip strength recovered to the level of the contralateral side. No postoperative complication was detected. The mean SANE score improved from 44 ± 23 (0–70) to 82 ± 12 (60–90) after a mean of 72 ± 20 (44–114) months. The mean postoperative brief MHQ was 92 ± 8 (71–98).
Conclusion
The use of 3D PSI in treating intra-articular malunions at the trapeziometacarpal and finger joints restored articular congruency accurately. ROM and grip strength improved postoperatively comparable to the healthy contralateral side and patient-reported outcome measures improved after medium-term follow-up.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We report the case of a 35-year-old patient who presented with a septic residual synovial cavity infection 8 weeks after a through-the-knee amputation because of a parosteal sarcoma. An endoscopic ...evacuation of the turbid fluid and synovial debridement through parapatellar portals as in a standard knee arthroscopy was performed, in conjunction with appropriate antibiotic therapy. One year postoperatively, there were no signs of residual infection.
Endoscopic treatment of a septic stump infection of the residual synovial cavity after through-the-knee amputation is feasible. In our case, this approach resulted in rapid wound healing and early prosthesis mobility.
A retrospective, single center, case-control study was performed.
The present study employed patient-specific biomechanical modeling to find potential biomechanical differences after spinal fusion at ...L4/5 in patients with and without subsequent development of adjacent segment disease (ASD).
The study population comprised patients who underwent primary spinal fusion at L4/5 and were either asymptomatic during > 4 years of follow-up (CTRL; n = 18) or underwent revision surgery for ASD at L3/4 (n = 20). Landmarks were annotated on preoperative and follow-up lateral radiographs, and specific musculoskeletal models were created using a custom-built modeling pipeline. Simulated spinal muscle activation and lumbar intervertebral shear loads in unfused segments were analyzed in upright standing and forward flexion. Differences between the pre- and postoperative conditions were computed for each patient.
The average postoperative muscle activity in the upright standing posture was 88.4% of the preoperative activity in the CTRL group (p < 0.0001), but did not significantly change from pre- to postoperatively in the ASD group (98.0%). The average shear load magnitude at the epifusional joint L3/4 during upright standing increased from pre- to postoperatively in the ASD group (+ 3.9 N, +/- 17.4 (n = 18)), but decreased in the CTRL group (- 4.6 N, +/- 23.3 (n = 20); p < 0.001).
Patient-specific biomechanical simulation revealed that spinal fusion surgery resulted in greater shear load magnitude and muscle activation and therefore greater forces at the epifusional segment in those with ASD compared with those without ASD. This is a first report of patient-specific disc load and muscle force calculation with predictive merits for ASD.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
Background
Use of automated systems for the production of chemotherapy will increase in answer to hospitals’ needs to rationalise production. The aim of the study was to evaluate the ...performance of a PharmaHelp
®
automated system for compounding chemotherapy.
Methods
Viable and non viable particles in air and liquid were measured by particle counter. Surface chemical contamination was simulated with a quinine solution. Microbiological contamination and aseptic processes were studied using media-fill tests. Dose accuracy was evaluated using a gravimetric method, in simulation studies and with real products in daily practice. Productivity was calculated by batch of ten IV-bags.
Results
No particles or microbiological contamination were detected. Filling was accurate for all the volumes of non-viscous solution studied (97–103 %). Minimum volumes which could be prepared accurately were 2 mL and 5 mL for the non-viscous and viscous solutions, respectively. For 2–5 mL volumes, the robot was less accurate than average, and 0–2 % of bags were rejected (deviation>10 %). Average fill deviations were from 0–3 % for 2–5 mL volumes and<1 % for volumes above 5 mL. Average production time for ten bags was 61±11 min.
Conclusions
The automated system was able to produce chemotherapy effectively, delivering appropriate quality with productivity comparable to manual preparations. These results confirmed that such automated systems have the potential to guarantee optimal safety for patients and technicians.