Yebes 40m radio telescope is the main and largest observing instrument at Yebes Observatory and it is devoted to Very Long Baseline Interferometry (VLBI) and single dish observations since 2010. It ...has been covering frequency bands between 2 GHz and 90 GHz in discontinuous and narrow windows in most of the cases, to match the current needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA).
Nanocosmos project, a European Union funded synergy grant, opened the possibility to increase the instantaneous frequency coverage to observe many molecular transitions with single tunnings in single dish mode. This reduces the observing time and maximises the output from the telescope.
We present the technical specifications of the recently installed 31.5 - 50GHz (Q band) and 72 - 90.5 GHz (W band) receivers along with the main characteristics of the telescope at these frequency ranges. We have observed IRC+10216, CRL 2688 and CRL 618, which harbour a rich molecular chemistry, to demonstrate the capabilities of the new instrumentation for spectral observations in single dish mode.
The results show the high sensitivity of the telescope in the Q band. The spectrum of IRC+10126 offers a signal to noise ratio never seen before for this source in this band. On the other hand, the spectrum normalised by the continuum flux towards CRL 618 in the W band demonstrates that the 40 m radio telescope produces comparable results to those from the IRAM 30 m radio telescope, although with a smaller sensitivity. The new receivers fulfil one of the main goals of Nanocosmos and open the possibility to study the spectrum of different astrophysical media with unprecedented sensitivity.
In this study we have developed and evaluated an analytical method for a rapid automated screening and confirmation of a large number of organic micro-contaminants (almost 400) and also the ...quantification of the positive findings in water samples of different types (surface and wastewaters) using liquid chromatography–electrospray quadrupole-time-of-flight mass spectrometry (LC–QTOFMS) based on the use of an accurate-mass database. The created database includes data not only on the accurate masses of the target ions but also on the characteristic in-source fragment ions, isotopic pattern and retention time data. This customized database was linked to commercially available software which extracted all the potential compounds of interest from the LC–QTOFMS raw data of each sample and matched them against the database to search for targeted compounds in the sample. The detailed fragmentation information has also been used as a powerful tool for the automatic identification of unknown compounds and/or transformation products with similar structures to those of known organic contaminants included in the database. The database can be continually enlarged. To confirm identification of compounds which have no fragment ions (or fragments with low intensity/relative abundance) from in-source CID fragmentation or isomers which are not distinguished within full single mass spectra, a “Targeted MS/MS” method is developed. Thereafter, these compounds can be further analyzed using the collision energy (CE) in QTOF-MS/MS mode. Linearity and limits of detection were studied. Method detection limits (MDLs) in effluent wastewater and river waters were, in most cases, lowers or equal to 5 and 2
ng/L, respectively. Only 15 compounds had MDLs between 5 and 50
ng/L in effluent wastewater matrix. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to real samples and the results obtained reveal that most of the pharmaceutically active compounds contained in the created database were present in the water samples with concentrations in the range of ng/L and μg/L levels and in most of the samples between 2 and 15 pesticides of the 300 contained in the database were also detected. In addition to the compounds included in the database, some degradation products were found, thus revealing the method as a useful tool for the analysis of organic micro-contaminants in waters.
There is emerging literature demonstrating a relationship between the timing of feeding and weight regulation in animals. However, whether the timing of food intake influences the success of a ...weight-loss diet in humans is unknown.
To evaluate the role of food timing in weight-loss effectiveness in a sample of 420 individuals who followed a 20-week weight-loss treatment.
Participants (49.5% female subjects; age (mean ± s.d.): 42 ± 11 years; BMI: 31.4 ± 5.4 kg m(-2)) were grouped in early eaters and late eaters, according to the timing of the main meal (lunch in this Mediterranean population). 51% of the subjects were early eaters and 49% were late eaters (lunch time before and after 1500 hours, respectively), energy intake and expenditure, appetite hormones, CLOCK genotype, sleep duration and chronotype were studied.
Late lunch eaters lost less weight and displayed a slower weight-loss rate during the 20 weeks of treatment than early eaters (P=0.002). Surprisingly, energy intake, dietary composition, estimated energy expenditure, appetite hormones and sleep duration was similar between both groups. Nevertheless, late eaters were more evening types, had less energetic breakfasts and skipped breakfast more frequently that early eaters (all; P<0.05). CLOCK rs4580704 single nucleotide polymorphism (SNP) associated with the timing of the main meal (P=0.015) with a higher frequency of minor allele (C) carriers among the late eaters (P=0.041). Neither sleep duration, nor CLOCK SNPs or morning/evening chronotype was independently associated with weight loss (all; P>0.05).
Eating late may influence the success of weight-loss therapy. Novel therapeutic strategies should incorporate not only the caloric intake and macronutrient distribution - as is classically done - but also the timing of food.
Adjuvant trastuzumab in HER2+ breast cancer reduces recurrence and mortality, and has been the standard treatment since 2006. The objective was to analyze health outcomes in the real world. ...Observational, retrospective study of patients with HER2+ breast cancer, stages I-III, treated with adjuvant trastuzumab in the past 15 years in only one center and for the first time in Spain. Survival was analyzed according to the number of cycles and cardiotoxicity. Two hundred and seventy-five HER2positive patients (18.60%) out of 1479 received adjuvant (73%) or neoadjuvant/adjuvant (26%) trastuzumab, concomitantly (90%) or sequentially (10%) with chemotherapy. The probability of overall and disease-free survival (OS and DFS) at 5 years was 0.93 (95% CI 0.89-0.96), and 0.88 (95% CI 0.83-0.92). The number of cases with a significant and asymptomatic decrease in ventricular ejection fraction and heart failure were 54 (19.64%) and 12 (4.36%), respectively. Sixty-eight patients (24.70%) received 16 or fewer cycles, especially those older than 65 (OR 0.371, 95% CI 0.152-0.903; p = 0.029) and with cardiotoxicity (OR 15.02, 95% CI 7.437-30.335; p < 0.001). The risk of cardiotoxicity was associated with having received radiotherapy (OR 0.0362, 95% CI 0.139-0.938; p = 0.037). Arterial hypertension (HR 0.361, 95% CI 0.151-0.863, p = 0.022), neoadjuvant treatment (HR 0.314, 95% CI 0.132-0.750, p = 0.009) and cardiotoxicity (HR 2.755, 95% CI 1.235-6.143, p = 0.013) maintained significant association with OS. Only neoadjuvant treatment maintained a significant association with DFS (HR 0.437, 95% CI 0.213-0.899, p = 0.024). The effectiveness of neoadjuvant and adjuvant trastuzumab can be considered comparable to those of clinical trials. In the real world, factors such as age, hypertension, radiotherapy, neoadjuvant treatment, and cardiotoxicity should be taken into consideration to optimize outcomes.
Summary
Pre‐operative anaemia in patients undergoing major surgical procedures has been linked to poor outcomes. Therefore, early detection and treatment of pre‐operative anaemia is recommended. ...However, to effectively implement a pre‐operative anaemia management protocol, an estimation of its prevalence and main causes is needed. We analysed data from 3342 patients (44.5% female) scheduled for either: elective orthopaedic surgery (n = 1286); cardiac surgery (n = 691); colorectal cancer resection (n = 735); radical prostatectomy (n = 362); gynaecological surgery (n = 203) or resection of liver metastases (n = 122). For both sexes, anaemia was defined by a haemoglobin level < 130 g.l−1; absolute iron deficiency by ferritin < 30 ng.ml−1 (< 100 ng.ml−1, if transferrin saturation < 20% or C‐reactive protein > 5 mg.l−1); iron sequestration by transferrin saturation < 20% and ferritin > 100 ng.ml−1; and low iron stores by transferrin saturation > 20% and ferritin 30–100 ng.ml−1. The overall prevalence of anaemia was 36%, with differences according to the type of surgery. Laboratory parameters allowing classification of iron status were available for 2884 patients. Among those with anaemia (n = 986), 677 (69%) were women, 608 (62%) presented with absolute iron deficiency, 101 (10%) with iron sequestration; and 150 (5%) with low iron stores. Iron status alterations were similar in women with haemoglobin < 130 g.l−1 or < 120 g.l−1. For those who were not anaemic (n = 1898), corresponding figures were 656 (35%), 621 (33%), 165 (9%) and 518 (27%), respectively. Anaemia was present in one‐third of patients undergoing major elective procedures. Over two‐thirds of anaemic patients presented with absolute iron deficiency or iron sequestration. Over half of non‐anaemic patients presented with absolute iron deficiency or low iron stores. We consider these data useful for planning pre‐operative management of patients scheduled for major elective surgery.
☛ CPD available at http://www.learnataagbi.org
BACKGROUNDSpain has been one of the countries most affected by the COVID-19 pandemic. OBJECTIVETo create a registry of patients with COVID-19 hospitalized in Spain, in order to improve our knowledge ...of the clinical, diagnostic, therapeutic, and prognostic aspects of this disease. METHODSA multicentre retrospective cohort study, including consecutive patients hospitalized with confirmed COVID-19 throughout Spain. Epidemiological and clinical data, additional tests at admission and at seven days, treatments administered, and progress at 30 days of hospitalization were collected from electronic medical records. RESULTSUp to June 30th 2020, 15,111 patients from 150 hospitals were included. Their median age was 69.4 years (range: 18-102 years) and 57.2% were male. Prevalences of hypertension, dyslipidemia, and diabetes mellitus were 50.9%, 39.7%, and 19.4%, respectively. The most frequent symptoms were fever (84.2%) and cough (73.5%). High values of ferritin (73.5%), lactate dehydrogenase (73.9%), and D-dimer (63.8%), as well as lymphopenia (52.8%), were frequent. The most used antiviral drugs were hydroxychloroquine (85.6%) and lopinavir/ritonavir (61.4%); 33.1% developed respiratory distress. Overall mortality rate was 21.0%, with a marked increase with age (50-59 years: 4.7%, 60-69 years: 10.5%, 70-79 years: 26.9%, ≥80 years: 46.0%). CONCLUSIONSThe SEMI-COVID-19 Network provides data on the clinical characteristics of patients with COVID-19 hospitalized in Spain. Patients with COVID-19 hospitalized in Spain are mostly severe cases, as one in three patients developed respiratory distress and one in five patients died. These findings confirm a close relationship between advanced age and mortality.
In this work we briefly describe the most relevant features of WSXM, a freeware scanning probe microscopy software based on MS-Windows. The article is structured in three different sections: The ...introduction is a perspective on the importance of software on scanning probe microscopy. The second section is devoted to describe the general structure of the application; in this section the capabilities of WSXM to read third party files are stressed. Finally, a detailed discussion of some relevant procedures of the software is carried out.
Seventeen Middle Pleistocene crania from the Sima de los Huesos site (Atapuerca, Spain) are analyzed, including seven new specimens. This sample makes it possible to thoroughly characterize a Middle ...Pleistocene hominin paleodeme and to address hypotheses about the origin and evolution of the Neandertals. Using a variety of techniques, the hominin-bearing layer could be reassigned to a period around 430,000 years ago. The sample shows a consistent morphological pattern with derived Neandertal features present in the face and anterior vault, many of which are related to the masticatory apparatus. This suggests that facial modification was the first step in the evolution of the Neandertal lineage, pointing to a mosaic pattern of evolution, with different anatomical and functional modules evolving at different rates.
A one-year monitoring study was performed to evaluate the occurrence, persistence and fate of a group of 14 organic compounds in a sewage treatment plant (STP) located in the south of Spain. These ...results are part of a more extensive study, financed by the Spanish Ministry of Research with the aim to evaluate the traceability of new pollutants on the Mediterranean coast and to determine the removal efficiency of sewage treatment plants (STP) for these pollutants. The compounds which have been analyzed include pharmaceuticals of various therapeutic categories (ibuprofen, acetaminophen, dipyrone, diclofenac, carbamazepine and codeine), pesticides (chlorfenvinfos and permethrin), caffeine, triclosan, bisphenol A and three of their more relevant metabolites (1,7-dimethylxanthine, carbamazepine 10,11-epoxide and 2,7/2,8-dichlorodibenzo-
p-dioxin). An SPE/GC–MS multi-residue analytical method was developed and validated to facilitate simultaneous determination of these compounds in both influent and effluent wastewater. The method provided mean recoveries higher than 75%, with the exception of 2,7/2,8-dichlorodibenzo-
p-dioxin, dipyrone and permethrin which exhibited recoveries lower than 22%. The overall variability of the method was below 14%. The method detection limit (LOD) was between 1 and 100
ng
l
−1 and precision, which was calculated as relative standard deviation (RSD), ranged from 1.8% to 11.2%. The application of the proposed method has allowed the identification of all the target compounds at mean concentrations which ranged from 0.12 to 134
μg
l
−1 in the influent and from 0.09 to 18.0
μg
l
−1 in the effluent. The removal efficiencies of the STP for these compounds varied from 20% (carbamazepine) to 99% (acetaminophen), but in all cases resulted insufficient in order to avoid their presence in treated water and subsequently in the environment.
Here we present deep (16 Jy beam−1), very high (40 mas) angular resolution 1.14 mm, polarimetric, Atacama Large Millimeter/submillimeter Array (ALMA) observations toward the massive protostar driving ...the HH 80-81 radio jet. The observations clearly resolve the disk oriented perpendicularly to the radio jet, with a radius of 0 171 (∼291 au at 1.7 kpc distance). The continuum brightness temperature, the intensity profile, and the polarization properties clearly indicate that the disk is optically thick for a radius of R 170 au. The linear polarization of the dust emission is detected almost all along the disk, and its properties suggest that dust polarization is produced mainly by self-scattering. However, the polarization pattern presents a clear differentiation between the inner (optically thick) part of the disk and the outer (optically thin) region of the disk, with a sharp transition that occurs at a radius of ∼0 1 (∼170 au). The polarization characteristics of the inner disk suggest that dust settling has not occurred yet with a maximum dust grain size between 50 and 500 m. The outer part of the disk has a clear azimuthal pattern but with a significantly higher polarization fraction compared to the inner disk. This pattern is broadly consistent with the self-scattering of a radiation field that is beamed radially outward, as expected in the optically thin outer region, although contribution from non-spherical grains aligned with respect to the radiative flux cannot be excluded.