This study evaluates the wear resistance of dental paste-like bulk-fill composites compared to conventional paste-like composite resins using an intraoral scanner and 3-D analyzing software. Six ...different dental composite materials, including five bulk-fill composites and one conventional composite, were tested alongside natural human enamel as a control group. A computer-controlled chewing simulator for wear testing. A one-way ANOVA test was used to identify any significant differences between the means of the tested dental composite materials α=0.05. The results showed variability among bulk-fill composites, with some demonstrating wear resistance similar to conventional composites (p<0.05). Human enamel displayed the lowest wear values, but some bulk-fill composites matched this resistance(p>0.05). Significant variability was observed among bulk-fill composites but the results were comparable to those of conventional composites. The enamel control group demonstrated the lowest wear values, with some bulk-fill composites showing similar wear resistance. This study provides valuable information about the wear resistance of contemporary bulk-fill composite materials, commonly used in current clinical practice, contributing to enhancing clinical procedures.
The aim of this study was to investigate the microshear bond strength (μSBS) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) ...restorative materials repaired with a composite resin.
Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The μSBS of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at
< 0.05.
The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (
< 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (
< 0.05).
The μSBS values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The μSBS values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.
Purpose: This study assessed radiopacity of resin-based computer-aided-design/computer-aided-manufacturing (CAD/CAM) materials by areal grayscale pixel value measurement.Methods: Radiopacities of six ...resin-based CAD/CAM block materials and resin composite were evaluated and compared to that of enamel and dentin. Specimens of 1-mm thickness were placed on photostimulable phosphor plate and irradiated with digital x-ray unit. On the radiographic image, regions of interests were determined for each specimen and areal grayscale pixel values were measured. Elemental analysis was performed with energy-dispersive x-ray spectroscopy (EDS) on field emission scanning electron microscope (FESEM) images of the specimens. Data were analyzed statistically (α = 0.05).Results: Radiopacity values of the restorative materials were significantly different from each other (P < 0.05). Radiopacity values of two resin-based CAD/CAM materials were significantly lower than that of dentin (P < 0.05). All tested restorative materials contain zirconium, three materials contain barium, and only resin composite contains lanthanum.Conclusion: Four CAD/CAM materials with higher amounts of zirconia or barium (>18%) had radiopacity values significantly higher than the dentin; while two materials with lower amounts of zirconia (<4%) and/or no-barium, had radiopacity values significantly lower than the dentin. EDS analysis suggests materials containing elements with higher atom numbers such as zirconia and barium could exhibit higher radiopacity.
Purpose: This study aimed to compare the effect of smoking cigarettes and drinking beverages and also polishing procedures on the discoloration of CAD/CAM materials.
Materials and Methods: Resin ...nanoceramic (Lava Ultimate-RN), feldspar ceramic (CEREC Blocs Ceramics-FC) and lithium disilicate glass-ceramic (IPS e.max® CAD-LDC) specimens (5X5 X2 mm) were used for this study. Initially, baseline surface roughness (Ra) and color values (L*, a*, b*) of the specimens were measured with profilometer and chroma meter. Then the specimens were exposure nicotine, coffee and red wine. The first discoloration values of each specimen were measured. Then, all of the specimens were subjected to re-polishing procedures. Than, the surface roughness and color values of each specimen were measured. The specimens were subjected to the same staining process again. After exposure of the specimens to the staining agents, the second staining value was measured. Two-way analysis of variance (ANOVA) was used for normally distributed groups, and the Kruskal-Wallis test was used for non-normally distributed groups.
Results: Statistically significant ΔE* values were observed for RN (8.26±1.55) and FC (7.69±1.52) for nicotine in the first staining group. The maximum total color changes were observed in the nicotine group for all of the material specimens. Nicotine caused the highest color changes on the test materials than coffee and wine. Surface roughness did not show a statistically significant difference based on the staining agents for any of the materials within a group (p<0.05).
Conclusions: It was observed that nicotine staining is far stronger than beverage staining.
Purpose: This study aimed to compare the effect of smoking cigarettes and drinking beverages and also polishing procedures on the discoloration of CAD/CAM materials.
Materials and Methods: Resin ...nanoceramic (Lava Ultimate-RN), feldspar ceramic (CEREC Blocs Ceramics-FC) and lithium disilicate glass-ceramic (IPS e.max® CAD-LDC) specimens (5X5 X2 mm) were used for this study. Initially, baseline surface roughness (Ra) and color values (L*, a*, b*) of the specimens were measured with profilometer and chroma meter. Then the specimens were exposure nicotine, coffee and red wine. The first discoloration values of each specimen were measured. Then, all of the specimens were subjected to re-polishing procedures. Than, the surface roughness and color values of each specimen were measured. The specimens were subjected to the same staining process again. After exposure of the specimens to the staining agents, the second staining value was measured. Two-way analysis of variance (ANOVA) was used for normally distributed groups, and the Kruskal-Wallis test was used for non-normally distributed groups.
Results: Statistically significant ΔE* values were observed for RN (8.26±1.55) and FC (7.69±1.52) for nicotine in the first staining group. The maximum total color changes were observed in the nicotine group for all of the material specimens. Nicotine caused the highest color changes on the test materials than coffee and wine. Surface roughness did not show a statistically significant difference based on the staining agents for any of the materials within a group (p<0.05).
Conclusions: It was observed that nicotine staining is far stronger than beverage staining.
The aim of this study was to compare the effects of conventional, sonic or pre-heating insertion techniques on internal void formation of bulk-fill composites with micro-computed tomography. ...Standardized cylindrical cavities were prepared in 160 human third molars. Four groups received different paste-like bulk-fill composites: SonicFill 2 (SF2); VisCalor Bulk (VCB); Filtek One Bulk-fill restorative (FBF); Tetric EvoCeram Bulk Fill (TEB); and a conventional posterior composite, Clearfil Majesty Posterior (CMP). A hybrid CAD/CAM block was selected as a control (n=10). Composite restorations were built according to each resin composite type and insertion technique (n=10). Micro-CT was used to assess internal void rates. Data was analyzed with two-way ANOVA and Tukey’s multiple comparisons test (α=0.05). CAD/CAM blocks were free of voids. For each composite, the highest void rates were observed for the sonic delivery method (p<0.05) except for SF2. SF2 was not affected by insertion techniques (p>0.05). Other composites showed the lowest void rates with pre-heating technique.
: The aim of this quantitative research was to investigate the effect of gravitational forces on the marginal integrity of different bulk-fill composites by micro-CT imaging.
: Fifty caries-free ...human third molars extracted for prophylactic purposes were used in this study. Each tooth was prepared with two proximal box cavities, with dimensions of 3 mm × 3 mm × 5 mm. Five distinct groups, each comprising 20 cavities, thus totaling 100 cavities for this study: (1, Group CON): Clearfil Majesty Flow + Clearfil Majesty Esthetic (as the control); (2, Group FBR): Filtek Bulk-fill Flowable Restorative + Clearfil Majesty Esthetic; (3, Group XTB): Voco Extrabase + Clearfil Majesty Esthetic; (4, Group SDR): SDR + Clearfil Majesty Esthetic; and (5, Group SNC): Sonicfill. When restoring the mesial cavities, the occlusal surfaces of the teeth in the mold were positioned upwards, counteracting the force of gravity. In contrast, for the restoration of the distal cavities, the occlusal surfaces were aligned downwards, to be parallel with the gravitational pull. After restorative procedures, each tooth was treated with 5000 thermal cycles. A solution of ammoniacal silver nitrate (AgNO
) was employed as a tracing agent. The micro-CT scans were conducted and the total volume of silver nitrate and the total volume of restorations within the relevant region of interest were calculated in "mm
" with software. Two-way ANOVA and Tukey tests were performed at a significance level of
= 0.05 with Graphpad Prism v 8.2.1 software.
: Both gravity effect and interaction showed no statistical differences (
> 0.05). Statistically significant differences were observed in the restorative materials (
< 0.05).
: Gravitational forces do not emerge as a major factor affecting the marginal integrity of flowable bulk-fill composites in class II restorations. The chemical composition of the composites plays a more crucial role, with the XTB composite showing higher microleakage ratios compared to the others.
The aim of this study was to evaluate the cytotoxicity of universal adhesives on L929 mouse fibroblast cell line by using a real-time cell analysis. In order to obtain extract, six different cured ...dental adhesives were immersed in Dulbecco’s Modified Eagle’s Medium (DMEM) at 37°C for 24 h. A real-time cell analysis system was used to assess cytotoxicity of the dental adhesives. After seeding 25,000 cells/300 μL/well cell suspensions into the wells of an e-plate, fibroblasts were exposed to extracts of tested adhesives at varying dilutions (1:1, 1:2, and 1:10) and observed at every 30 min intervals for 72 h. Three-way ANOVA one factor repeated measures were used to analyze the results (α=0.05). All tested adhesives induced cell viability loss, cell morphology alteration, and cell death depending on extract concentration and time. Cell viability of L929 cells to between 44 and 10% for 1:1 diluted extracts, at 72 h, when compared to the negative control.
The purpose of this study is to evaluate the marginal adaptation of bulk-fill resin composites with different viscosities (paste-like and flowable) in Class II restorations using micro-CT imaging.
...Forty extracted human molars were used. Mesial and distal Class II box cavities (approximately 3 mm x 3 mm x 4 mm) were prepared for each tooth, with cavity floors located 1 mm below the enamel-cementum junction. Following adhesive application, teeth were restored using eight different groups: Group XB: X-tra Base Bulk-fill Flowable (VOCO), Group XF: X-tra Fill Bulk-fill (VOCO), Group FB: Filtek Bulk-fill Posterior (3 M ESPE), Group FF: Filtek Bulk-fill Flowable (3 M ESPE), Group BB: Beautifil-Bulk (SHOFU), Group BF: Beautifil-Bulk Flowable (SHOFU), and Group CO: "as a control group", Clearfil Majesty Posterior (KURARAY) and Group CF: "as a control group", Clearfil Majesty Flow + Clearfil Majesty Posterior (KURARAY). The restored teeth underwent an aging protocol involving 1000 cycles in a water bath fluctuating between 5 ± 1.0 °C and 55 ± 1.0 °C. Post-aging, teeth were immersed in 50% silver nitrate solution for 24 h and then in a film developer solution for 8 h. Microleakage analysis was performed using micro-CT, evaluated with 3D Slicer software. A two-way ANOVA was employed for statistical analysis.
Two-way ANOVA results indicated significant effects of both viscosity (p < 0.0001) and composite type (p < 0.0001) on marginal adaptation. Viscosity analysis (comparing flowable and paste-like) revealed no significant differences in the FB-FF, XB-XF and BB-BF groups but significant differences in the and CO-CF group, with flowable type exhibiting less microleakage than paste-like type.
The study suggests that while the viscosity of bulk-fill composites did not significantly affect marginal adaptation, the brand of bulk-fill composite did influence it.