Abstract
We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. ...FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics.
The Boulby Underground Germanium Suite (BUGS) comprises three low-background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the ...north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radio-assay programme to support the development of rare-event search experiments. A Broad Energy Germanium (BEGe) detector delivers sensitivity to low-energy gamma-rays such as those emitted by 210Pb and 234Th. A Small Anode Germanium (SAGe) well-type detector is employed for efficient screening of small samples. Finally, a standard p-type coaxial detector provides fast screening of standard samples. This paper presents the steps used to characterise the performance of these detectors for a variety of sample geometries, including the corrections applied to account for cascade summing effects. For low-density materials, BUGS is able to radio-assay to specific activities down to 3.6mBqkg−1 for 234Th and 6.6mBqkg−1 for 210Pb both of which have uncovered some significant equilibrium breaks in the 238U chain. In denser materials, where gamma-ray self-absorption increases, sensitivity is demonstrated to specific activities of 0.9mBqkg−1 for 226Ra, 1.1mBqkg−1 for 228Ra, 0.3mBqkg−1 for 224Ra, and 8.6mBqkg−1 for 40K with all upper limits at a 90% confidence level. These meet the requirements of most screening campaigns presently under way for rare-event search experiments, such as the LUX-ZEPLIN (LZ) dark matter experiment. We also highlight the ability of the BEGe detector to probe the X-ray fluorescence region which can be important to identify the presence of radioisotopes associated with neutron production; this is of particular relevance in experiments sensitive to nuclear recoils.
We present systematic case studies to investigate the sensitivity of axion searches by liquid xenon detectors, using the axio-electric effect (analogue of the photoelectric effect) on xenon atoms. ...Liquid xenon is widely considered to be one of the best target media for detection of WIMPs (Weakly Interacting Massive Particles which may form the galactic dark matter) using nuclear recoils. Since these detectors also provide an extremely low radioactivity environment for electron recoils, very weakly-interacting low-mass particles (< 100keV/c2), such as the hypothetical axion, could be detected as well – in this case using the axio-electric effect. Future ton-scale liquid Xe detectors will be limited in sensitivity only by irreducible neutrino background (pp-chain solar neutrino and the double beta decay of 136Xe) in the mass range between 1 and 100keV/c2. Assuming one ton-year of exposure, galactic axions (as non-relativistic dark matter) could be detected if the axio-electric coupling gAe is greater than 10−14 at 1keV/c2 axion mass (or 10−13 at 100keV/c2). Below a few keV/c2, and independent of the mass, a solar axion search would be sensitive to a coupling gAe∼10-12. This limit will set a stringent upper bound on axion mass for the DFSZ and KSVZ models for the mass ranges mA<0.1 eV/c2 and <10eV/c2, respectively. Vector-boson dark matter could also be detected for a coupling constant α′/α>10-33 (for mass 1keV/c2) or >10-27 (for mass 100keV/c2).
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive ...particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
Abstract
As we move to an era where next generation ultra-low
background particle physics experiments begin to be designed and
constructed, the ability to assay materials with high sensitivity
and at ...speed with a variety of techniques will be key.
This paper describes the Mirion Technologies (Canberra) specialty
ultra-low background detectors installed and commissioned at the
Boulby Underground Laboratory between 2017 and 2021. The low
background levels of the detectors combine with low background
shielding and a radon-reduced dry nitrogen purge system to give
sensitivity approaching the best in the world without the need for
intricate shielding solutions.
For an optimised sample geometry, run for 100 d, it would be
possible to reach close to 10 μBq kg
-1
(10
-12
g/g) for background radionuclides of interest in
neutrinoless double-beta decay.
To satisfy the requirements of the next generation of dark matter detectors based on the dual phase TPC, Hamamatsu, in close collaboration with UCLA, has developed the R11410-10 photomultiplier tube. ...In this work, we present the detailed tests performed on this device. High QE (∼30%) accompanied by a low dark count rate (50Hz at 0.3 PE) and high gain (1×107) with good single PE resolution have been observed. A comprehensive screening measurement campaign is ongoing while the manufacturer quotes a radioactivity of 20mBq/PMT. These characteristics show the R11410-10 to be particularly suitable for the forthcoming zero background liquid xenon detectors.
► Requirements needed of PMTs for dark matter searches. ► Systematic tests of 3-in. Hamamatsu R11410-PMT for dark matter detectors. ► Results show high quantum efficiency, low radioactivity, and low noise properties. ► PMT demonstrates suitable qualities necessary for rare event searches.
► DRIFT is only one of a handful of directional dark matter detectors. ► A method of rejecting Radon Progeny Recoils, DRIFT’s main background, is discussed. ► Additionally DRIFT-IId was found to run ...stably with a mixture of CS2 and CF4. ► DRIFT’s sensitivity is orders of magnitude better than other directional detectors.
Data are presented from the DRIFT-IId detector operated in the Boulby Underground Science Facility in England. A 0.8m3 fiducial volume, containing partial pressures of 30Torr CS2 and 10Torr CF4, was exposed for a duration of 47.4 live-time days with sufficient passive shielding to provide a neutron free environment within the detector. The nuclear recoil events seen are consistent with a remaining low-level background from the decay of radon daughters attached to the central cathode of the detector. However, charge from such events must drift across the entire width of the detector, and thus display large diffusion upon reaching the readout planes of the device. Exploiting this feature, it is shown to be possible to reject energy depositions from these Radon Progeny Recoil events while still retaining sensitivity to fiducial-volume nuclear recoil events. The response of the detector is then interpreted, using the F nuclei content of the gas, in terms of sensitivity to proton spin-dependent WIMP–nucleon interactions, displaying a minimum in sensitivity cross section at 1.8pb for a WIMP mass of 100GeV/c2. This sensitivity was achieved without compromising the direction sensitivity of DRIFT.
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. ...An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated γ -ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV γ-rays. For the inner part of the detector ( R <; 100 mm) , spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
A
bstract
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss appli-cations enabled by the ...excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of ~3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two-phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter ...particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and
60Co γ-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225
kg
×
days. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5
keV
ee and 20
keV
ee, had an observed count of 29 events, with a summed expectation of 28.6
±
4.3 γ-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP–nucleon spin-independent cross-section with a minimum of 6.6
×
10
−7
pb following the inclusion of an energy-dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2
×
10
−7
pb for similar exposures as the first run.