Purpose:
The purpose of this study was to investigate the ability and efficacy of inducing sonoporation in a clinical setting, using commercially available technology, to increase the patients’ ...quality of life and extend the low Eastern Cooperative Oncology Group performance grade; as a result increasing the overall survival in patients with pancreatic adenocarcinoma.
Methods:
Patients were treated using a customized configuration of a commercial clinical ultrasound scanner over a time period of 31.5 min following standard chemotherapy treatment with gemcitabine. SonoVue® ultrasound contrast agent was injected intravascularly during the treatment with the aim to induce sonoporation.
Results:
Using the authors’ custom acoustic settings, the authors’ patients were able to undergo an increased number of treatment cycles; from an average of 9 cycles, to an average of 16 cycles when comparing to a historical control group of 80 patients. In two out of five patients treated, the maximum tumor diameter was temporally decreased to 80 ± 5% and permanently to 70 ± 5% of their original size, while the other patients showed reduced growth. The authors also explain and characterize the settings and acoustic output obtained from a commercial clinical scanner used for combined ultrasound microbubble and chemotherapy treatment.
Conclusions:
It is possible to combine ultrasound, microbubbles, and chemotherapy in a clinical setting using commercially available clinical ultrasound scanners to increase the number of treatment cycles, prolonging the quality of life in patients with pancreatic adenocarcinoma compared to chemotherapy alone.
The primary aim of our study was to evaluate the safety and potential toxicity of gemcitabine combined with microbubbles under sonication in inoperable pancreatic cancer patients. The secondary aim ...was to evaluate a novel image-guided microbubble-based therapy, based on commercially available technology, towards improving chemotherapeutic efficacy, preserving patient performance status, and prolonging survival.
Ten patients were enrolled and treated in this Phase I clinical trial. Gemcitabine was infused intravenously over 30min. Subsequently, patients were treated using a commercial clinical ultrasound scanner for 31.5min. SonoVue® was injected intravenously (0.5ml followed by 5ml saline every 3.5min) during the ultrasound treatment with the aim of inducing sonoporation, thus enhancing therapeutic efficacy.
The combined therapeutic regimen did not induce any additional toxicity or increased frequency of side effects when compared to gemcitabine chemotherapy alone (historical controls). Combination treated patients (n=10) tolerated an increased number of gemcitabine cycles compared with historical controls (n=63 patients; average of 8.3±6.0cycles, versus 13.8±5.6cycles, p=0.008, unpaired t-test). In five patients, the maximum tumour diameter was decreased from the first to last treatment. The median survival in our patients (n=10) was also increased from 8.9months to 17.6months (p=0.011).
It is possible to combine ultrasound, microbubbles, and chemotherapy in a clinical setting using commercially available equipment with no additional toxicities. This combined treatment may improve the clinical efficacy of gemcitabine, prolong the quality of life, and extend survival in patients with pancreatic ductal adenocarcinoma.
Display omitted
Contrast-enhanced and targeted ultrasound Postema, Michiel; Gilja, Odd Helge
World journal of gastroenterology : WJG,
01/2011, Letnik:
17, Številka:
1
Journal Article
Odprti dostop
Ultrasonic imaging is becoming the most popular medical imaging modality,owing to the low price per examination and its safety.However,blood is a poor scatterer of ultrasound waves at clinical ...diagnostic transmit frequencies.For perfusion imaging,markers have been designed to enhance the contrast in B-mode imaging.These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells.In this review,the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described.Furthermore,an outline of clinical imaging applications of contrast-enhanced ultrasound is given.It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition,and how these phenomena may be utilized in ultrasonic imaging.Aided by high-speed photography,our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques.More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves,and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs.These are beginning to be accepted into clinical practice.In the long term,targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested.
Gut microbiota alterations are important in irritable bowel syndrome (IBS). The aim was to investigate the effect of fecal microbiota transplantation (FMT) on gut microbiota and the symptoms in ...patients with IBS.
The study included 13 IBS patients according to Rome III criteria and 13 healthy donors. Freshly donated feces were administered to the descending part of the duodenum via a gastroscope. Feces were collected from donors and patients before FMT, and from the patients at 1, 3 and 12 weeks and donors and patients at 20/28 weeks after FMT. Microbiota analysis was performed using GA-map Dysbiosis test (Genetic Analysis AS, Oslo, Norway). The patients completed the following questionnaires before and at the aforementioned weeks after FMT: IBS Symptom Questionnaire (IBS-SQ), IBS-Symptom Severity Scoring system (IBS-SSS), Short Form of Nepean Dyspepsia Index (SF-NDI), Bristol stool form scale, the Eysenck Personality Questionnaire-Neuroticism and Hospital Anxiety and Depression.
Donors and IBS patients had significantly different bacterial strain signals before FMT (Ruminococcus gnavus, Actinobacteria and Bifidobacteria) that became non-significant after 3 weeks following FMT. The changes in gut microbiota were similar between donors and patients at 20/28 weeks after FMT. Thus, patients' microbiota profiles became more-or-less similar to donors. The scores of all the questionnaires were significantly improved at all time points following FMT. No reported adverse effects.
FMT was associated with a change in gut microbiota and improvement in IBS symptoms and quality of life lasting for up to 28 weeks.
ClinicalTrials.gov ID: NCT03333291.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Establishing normal liver stiffness (LS) values in healthy livers is a prerequisite to differentiate normal from pathological LS values. Our aim was to define normal LS using two novel elastography ...methods head-to-head and to assess the number of measurements, variability and reproducibility.
We evaluated shear wave elastography (SWE) methods integrated in Samsung RS80A and GE S8 by obtaining LS measurements (LSM) in 100 healthy subjects (20-70 years). Transient Elastography (TE) was used as reference method. Data were analyzed according to age, sex, BMI and 5 vs. 10 measurements. All subjects underwent B-mode ultrasound examination and lab tests to exclude liver pathology. Interobserver variation was evaluated in a subset (n = 24).
Both methods showed excellent feasibility, measuring LS in all subjects. LSM-mean for GE S8 2D-SWE was higher compared to TE (4.5±0.8 kPa vs. 4.2±1.1, p<0.001) and Samsung RS80A (4.1±0.8 kPa, p<0.001). Both methods showed low intra- and interobserver variation. LSM-mean was significantly higher in males than females using 2D-SWE, while a similar trend for Samsung SWE did not reach significance. No method demonstrated statistical significant difference in LSM across age and BMI groups nor between LSM-mean based on 5 vs. 10 measurements.
LSM was performed with high reproducibility in healthy adult livers. LSM-mean was significantly higher for GE S8 2D-SWE compared to Samsung RS80A and TE in healthy livers. Males had higher LSM than females. No method demonstrated statistical significant difference in LSM-mean across age- and non-obese BMI groups. Our results indicate that five LSM may be sufficient for reliable results.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The widespread use of portable ultrasound scanners has promoted the concept of point of care ultrasound (POCUS), namely "ultrasound performed bedside and interpreted directly by the clinician." The ...purpose of this short review is to outline how POCUS can be used in patients with diseases of the gastrointestinal (GI) tract. POCUS is not a replacement for comprehensive ultrasound, but rather allows physicians immediate access to clinical imaging for rapid diagnosis and efficient work-up and treatment of the patients. There are many indications for doing POCUS of the GI tract, including abdominal pain, diarrhea, palpable masses, and to detect fluid or free air in the abdominal cavity. To improve the visibility of deeper parts of the abdomen, the graded compression technique with the scan head is useful. During POCUS, the operator should look for signs of severe pathology including target lesions, the pseudo-kidney sign, the onion sign, dilated bowel loops, gastric retention, free fluid, and free air, depending on the actual clinical problem. We conclude that POCUS of the GI tract is very useful to provide a rapid diagnosis in many clinical scenarios.
This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with ...different known Young's modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981-1.000 and intraclass correlation 0.987-1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young's modulus. All platforms had a coefficient of variation in the range 0.00-0.21 for all four phantoms, equivalent to low variance and high repeatability.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Background
We recently found fecal microbiota transplantation (FMT) in irritable bowel syndrome (IBS) patients to be an effective and safe treatment after 3 months. The present follow‐up study ...investigated the efficacy and safety of FMT at 1 year after treatment.
Methods
This study included 77 of the 91 IBS patients who had responded to FMT in our previous study. Patients provided a fecal sample and completed five questionnaires to assess their symptoms and quality of life at 1 year after FMT. The dysbiosis index (DI) and fecal bacterial profile were analyzed using a 16S rRNA gene‐based DNA probe hybridization. The levels of fecal short‐chain fatty acids (SCFAs) were determined by gas chromatography.
Results
There was a persistent response to FMT at 1 year after treatment in 32 (86.5%) and 35 (87.5%) patients who received 30‐g and 60‐g FMT, respectively. In the 30‐g FMT group, 12 (32.4%) and 8 (21.6%) patients showed complete remission at 1 year and 3 months, respectively; the corresponding numbers in the 60‐g FMT group were 18 (45%) and 11 (27.5%), respectively. Abdominal symptoms and the quality of life were improved at 1 year compared with after 3 months. These findings were accompanied by comprehensive changes in the fecal bacterial profile and SCFAs.
Conclusions
Most of the IBS patients maintained a response at 1 year after FMT. Moreover, the improvements in symptoms and quality of life increased over time. Changes in DI, fecal bacterial profile and SCFAs were more comprehensive at 1 year than after 3 months. www.clinicaltrials.gov (NCT03822299).
The study included 77 IBS patients who had responded to FMT 3 months after transplantation. There was a persistent response to FMT at 1 year after treatment in 86.5% and 87.5% patients who received 30‐g and 60‐g FMT, respectively. In addition, the complete remission rates increased. More comprehensive changes than those found after 3 months were observed regarding fecal bacterial profile and short chain fatty acids.
Point of Care Ultrasound: A WFUMB Position Paper Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana ...
Ultrasound in medicine & biology,
01/2017, Letnik:
43, Številka:
1
Journal Article
Recenzirano
Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by ...the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows physicians immediate access to clinical imaging for rapid and direct solutions. PoC-US has already revolutionized everyday clinical practice, and it is believed that it will dramatically change how ultrasound is applied in daily practice. However, its use and teaching are different from continent to continent and from country to country. This World Federation for Ultrasound in Medicine and Biology position paper discusses the current status and future perspectives of PoC-US. Particular attention is given to the different uses of PoC-US and its clinical significance, including within emergency and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training.
Sonography of the small intestine Nylund, Kim; Ødegaard, Svein; Hausken, Trygve ...
World journal of gastroenterology : WJG,
03/2009, Letnik:
15, Številka:
11
Journal Article
Odprti dostop
In the last two decades, there has been substantial development in the diagnostic possibilities for examining the small intestine. Compared with computerized tomography, magnetic resonance imaging, ...capsule endoscopy and double-balloon endoscopy, ultrasonography has the advantage of being cheap, portable, flexible and user- and patient-friendly, while at the same time providing the clinician with image data of high temporal and spatial resolution. The method has limitations with penetration in obesity and with intestinal air impairing image quality. The flexibility ultrasonography offers the examiner also implies that a systematic approach during scanning is needed. This paper reviews the basic scanning techniques and new modalities such as contrast-enhanced ultrasound, elastography, strain rate imaging, hydrosonography, allergosonography, endoscopic sonography and nutritional imaging, and the literature on disease-specific findings in the small intestine. Some of these methods have shown clinical benefit, while others are under research and development to establish their role in the diagnostic repertoire. However, along with improved overall image quality of new ultrasound scanners, these methods have enabled more anatomical and physiological changes in the small intestine to be observed. Accordingly, ultrasound of the small intestine is an attractive clinical tool to study patients with a range of diseases.