The Alpha Magnetic Spectrometer (AMS) is a precision particle physics detector on the International Space Station (ISS) conducting a unique, long-duration mission of fundamental physics research in ...space. The physics objectives include the precise studies of the origin of dark matter, antimatter, and cosmic rays as well as the exploration of new phenomena. Following a 16-year period of construction and testing, and a precursor flight on the Space Shuttle, AMS was installed on the ISS on May 19, 2011. In this report we present results based on 120 billion charged cosmic ray events up to multi-TeV energies. This includes the fluxes of positrons, electrons, antiprotons, protons, and nuclei. These results provide unexpected information, which cannot be explained by the current theoretical models. The accuracy and characteristics of the data, simultaneously from many different types of cosmic rays, provide unique input to the understanding of origins, acceleration, and propagation of cosmic rays.
Context. The positron fraction in cosmic rays has recently been measured with improved accuracy up to 500 GeV, and it was found to be a steadily increasing function of energy above ~10 GeV. This ...behaviour contrasts with standard astrophysical mechanisms, in which positrons are secondary particles, produced in the interactions of primary cosmic rays during their propagation in the interstellar medium. The observed anomaly in the positron fraction triggered a lot of excitement, as it could be interpreted as an indirect signature of the presence of dark matter species in the Galaxy, the so-called weakly interacting massive particles (WIMPs). Alternatively, it could be produced by nearby sources, such as pulsars. Aims. These hypotheses are probed in light of the latest AMS-02 positron fraction measurements. As regards dark matter candidates, regions in the annihilation cross section to mass plane, which best fit the most recent data, are delineated and compared to previous measurements. The explanation of the anomaly in terms of a single nearby pulsar is also explored. Methods. The cosmic ray positron transport in the Galaxy is described using a semi-analytic two-zone model. Propagation is described with Green functions as well as with Bessel expansions. For consistency, the secondary and primary components of the positron flux are calculated together with the same propagation model. The above mentioned explanations of the positron anomaly are tested using χ2 fits. The numerical package MicrOMEGAs is used to model the positron flux generated by dark matter species. The description of the positron fraction from conventional astrophysical sources is based on the pulsar observations included in the Australia Telescope National Facility (ATNF) catalogue. Results. The masses of the favoured dark matter candidates are always larger than 500 GeV, even though the results are very sensitive to the lepton flux. The Fermi measurements point systematically to much heavier candidates than the recently released AMS-02 observations. Since the latter are more precise, they are much more constraining. A scan through the various individual annihilation channels disfavours leptons as the final state. On the contrary, the agreement is excellent for quark, gauge boson, or Higgs boson pairs, with best-fit masses in the 10 to 40 TeV range. The combination of annihilation channels that best matches the positron fraction is then determined at fixed WIMP mass. A mixture of electron and tau lepton pairs is only acceptable around 500 GeV. Adding b-quark pairs significantly improves the fit up to a mass of 40 TeV. Alternatively, a combination of the four-lepton channels provides a good fit between 0.5 and 1 TeV, with no muons in the final state. Concerning the pulsar hypothesis, the region of the distance-to-age plane that best fits the positron fraction for a single source is determined. Conclusions. The only dark matter species that fulfils the stringent gamma ray and cosmic microwave background bounds is a particle annihilating into four leptons through a light scalar or vector mediator, with a mixture of tau (75%) and electron (25%) channels, and a mass between 0.5 and 1 TeV. The positron anomaly can also be explained by a single pulsar, and a list of five pulsars from the ATNF catalogue is given. We investigate how this list could evolve when more statistics are accumulated. Those results are obtained with the cosmic ray transport parameters that best fit the B/C ratio. Uncertainties in the propagation parameters turn out to be very significant. In the WIMP annihilation cross section to mass plane for instance, they overshadow the error contours derived from the positron data.
We report the observation of new properties of primary cosmic rays He, C, and O measured in the rigidity (momentum/charge) range 2 GV to 3 TV with 90×10^{6} helium, 8.4×10^{6} carbon, and 7.0×10^{6} ...oxygen nuclei collected by the Alpha Magnetic Spectrometer (AMS) during the first five years of operation. Above 60 GV, these three spectra have identical rigidity dependence. They all deviate from a single power law above 200 GV and harden in an identical way.
We report on the observation of new properties of secondary cosmic rays Li, Be, and B measured in the rigidity (momentum per unit charge) range 1.9 GV to 3.3 TV with a total of 5.4×10^{6} nuclei ...collected by AMS during the first five years of operation aboard the International Space Station. The Li and B fluxes have an identical rigidity dependence above 7 GV and all three fluxes have an identical rigidity dependence above 30 GV with the Li/Be flux ratio of 2.0±0.1. The three fluxes deviate from a single power law above 200 GV in an identical way. This behavior of secondary cosmic rays has also been observed in the AMS measurement of primary cosmic rays He, C, and O but the rigidity dependences of primary cosmic rays and of secondary cosmic rays are distinctly different. In particular, above 200 GV, the secondary cosmic rays harden more than the primary cosmic rays.
We report the observation of new properties of primary iron (Fe) cosmic rays in the rigidity range 2.65 GV to 3.0 TV with 0.62×10^{6} iron nuclei collected by the Alpha Magnetic Spectrometer ...experiment on the International Space Station. Above 80.5 GV the rigidity dependence of the cosmic ray Fe flux is identical to the rigidity dependence of the primary cosmic ray He, C, and O fluxes, with the Fe/O flux ratio being constant at 0.155±0.006. This shows that unexpectedly Fe and He, C, and O belong to the same class of primary cosmic rays which is different from the primary cosmic rays Ne, Mg, and Si class.
We report the observation of new properties of primary cosmic rays, neon (Ne), magnesium (Mg), and silicon (Si), measured in the rigidity range 2.15 GV to 3.0 TV with 1.8 × 106 Ne , 2.2 × 106 Mg , ...and 1.6 × 106 Si nuclei collected by the Alpha Magnetic Spectrometer experiment on the International Space Station. The Ne and Mg spectra have identical rigidity dependence above 3.65 GV. The three spectra have identical rigidity dependence above 86.5 GV, deviate from a single power law above 200 GV, and harden in an identical way. Unexpectedly, above 86.5 GV the rigidity dependence of primary cosmic rays Ne, Mg, and Si spectra is different from the rigidity dependence of primary cosmic rays He, C, and O. This shows that the Ne, Mg, and Si and He, C, and O are two different classes of primary cosmic rays.
In this work, we show a new procedure to obtain an optimum DC polarisation potential that allows achieving the maximum possible sensitivity for analyte determination, when electrochemical techniques ...are used. This is valid whether purely DC or AC potentials are used for system polarisation. In addition, the optimum potential is lower than the ones generally used by the classical methods, avoiding redox-active interferents and rapid degradation of the working electrode. In our case, we obtain a reduction of 16% of the DC applied potential and an increase among 3 and 5 times in the sensitivity.
Graphical abstract
•Conductive fabrics electrodeposited with iridium oxide films can measure pH change.•A fully stretched stainless steel mesh shows the best overall response to pH change.•A sweat pH measurement in ...human skin shows a relative error of 4% when compared with a standard method.
Determining the pH of sweat provides valuable information for athletes and patient monitoring. This work presents a textile-based, highly sensitive pH sensor for pH determination. Three conductive fabrics (Argenmesh, Ristop silver and stainless steel mesh (SSM)) were modified with a pH sensitive electrodeposited iridium oxide film (EIROF). The three electrodeposited fabrics were characterized by impedance measurements. The stainless steel mesh showed the best sensitivity to pH changes and therefore was selected for further experiments. Two configurations of this fabric were evaluated, looking for improvement in pH sensitivity and temperature dependence. The best result was obtained with the configuration that maximizes the contact surface between the stainless steel fibers, showing an error of 0.15% in the pH measurement of a buffer solution. This configuration was also used to perform in vivo measurements, obtaining an error of 4% when compared to the measurements performed with a commercial pH test strip. The implementation of sensor into textiles brings some advantages such as comfort, biocompatibility and washability, among others; making the future incorporation of a sensor into a garment very possible.
Results from a prototype TES detector for the Ricochet experiment Augier, C.; Baulieu, G.; Belov, V. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2023, Letnik:
1057
Journal Article
Recenzirano
Odprti dostop
Coherent elastic neutrino-nucleus scattering (CEνNS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a ...precision measurement of the CEνNS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of ∼30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the “Q-Array”) will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.
Abstract
We show the results of speckle contrast analysis at the MID instrument of European XFEL in the hard X-ray regime. Speckle patterns measured from static colloidal samples are compared to ...results previously obtained at the SPB/SFX instrument. A high degree of coherence of 0.79 is obtained by modelling the
q
-dependence of the speckle contrast, that corresponds to a number of coherent modes of
M
= 1.7. Furthermore, the variation of contrast over many pulse trains is exceptional low, resulting in a degree of coherence with a relative standard deviation below 0.1. Our results demonstrate the high stability of coherence properties at European XFEL over many X-ray pulses and pulse trains which is a prerequisite for coherence-based techniques such as MHz X-ray photon correlation spectroscopy.