Electrical impedance tomography (EIT) provides low-resolution images of internal conductivity distributions, but is able to achieve relatively high temporal resolutions. Most EIT image reconstruction ...algorithms do not explicitly account for the temporal constraints on the measurements or physiological processes under investigation. Instead, algorithms typically assume both that the conductivity distribution does not change during the acquisition of each EIT data frame, and that frames can be reconstructed independently, without consideration of the correlation between images. A failure to account for these temporal effects will result in aliasing-related artefacts in images. Several methods have been proposed to compensate for these effects, including interpolation of raw data, and reconstruction algorithms using Kalman and temporal filtering. However, no systematic work has been performed to understand the severity of the temporal artefacts nor the extent to which algorithms can account for them. We seek to address this need by developing a temporal comparison framework and figures of merit to assess the ability of reconstruction algorithms to account for temporal effects. Using this approach, we compare combinations of three reconstruction algorithms using three EIT data frame types: perfect, realistic and interpolated. The results show that, without accounting for temporal effects, artefacts are present in images for dynamic conductivity contrasts at frequencies 10-20 times slower than the frame rate. The proposed methods show some improvements in reducing these artefacts.
Lung and cardiovascular monitoring applications of electrical impedance tomography (EIT) require localization of relevant functional structures or organs of interest within the reconstructed images. ...We describe an algorithm for automatic detection of heart and lung regions in a time series of EIT images. Using EIT reconstruction based on anatomical models, candidate regions are identified in the frequency domain and image-based classification techniques applied. The algorithm was validated on a set of simultaneously recorded EIT and CT data in pigs. In all cases, identified regions in EIT images corresponded to those manually segmented in the matched CT image. Results demonstrate the ability of EIT technology to reconstruct relevant impedance changes at their anatomical locations, provided that information about the thoracic boundary shape (and electrode positions) are used for reconstruction.
Ineffective aeration during the first inflations at birth creates regional aeration and ventilation defects, initiating injurious pathways. This study aimed to compare a sustained first inflation at ...birth or dynamic end-expiratory supported recruitment during tidal inflations against ventilation without intentional recruitment on gas exchange, lung mechanics, spatiotemporal regional aeration and tidal ventilation, and regional lung injury in preterm lambs. Lambs (127 ± 2 d gestation), instrumented at birth, were ventilated for 60 minutes from birth with either lung-protective positive pressure ventilation (control) or as per control after either an initial 30 seconds of 40 cm H2O sustained inflation (SI) or an initial stepwise end-expiratory pressure recruitment maneuver during tidal inflations (duration 180 s; open lung ventilation OLV). At study completion, molecular markers of lung injury were analyzed. The initial use of an OLV maneuver, but not SI, at birth resulted in improved lung compliance, oxygenation, end-expiratory lung volume, and reduced ventilatory needs compared with control, persisting throughout the study. These changes were due to more uniform inter- and intrasubject gravity-dependent spatiotemporal patterns of aeration (measured using electrical impedance tomography). Spatial distribution of tidal ventilation was more stable after either recruitment maneuver. All strategies caused regional lung injury patterns that mirrored associated regional volume states. Irrespective of strategy, spatiotemporal volume loss was consistently associated with up-regulation of early growth response-1 expression. Our results show that mechanical and molecular consequences of lung aeration at birth are not simply related to rapidity of fluid clearance; they are also related to spatiotemporal pressure-volume interactions within the lung during inflation and deflation.
Fluorescence-guided surgical procedures are employed in an increasing number of applications such as tumor delineation, blood perfusion, and sentinel lymph node detection. A new generation of ...fluorescent probes is expected to increase the number of applications and improve efficiency. Yet, there are no available imaging methods to take full advantage of the forthcoming targeting technologies. We present a novel concept for imaging multiple agents for fluorescence-guided surgery. The system operates without any moving parts and can resolve images of three different fluorochromes while simultaneously recording conventional reflectance images.
A sustained first inflation (SI) at birth may aid lung liquid clearance and aeration, but the impact of SI duration relative to the volume-response of the lung is poorly understood. We compared three ...SI strategies: 1) variable duration defined by attaining volume equilibrium using real-time electrical impedance tomography (EIT; SIplat); 2) 30 s beyond equilibrium (SIlong); 3) short 30-s SI (SI30); and 4) positive pressure ventilation without SI (no-SI) on spatiotemporal aeration and ventilation (EIT), gas exchange, lung mechanics, and regional early markers of injury in preterm lambs. Fifty-nine fetal-instrumented lambs were ventilated for 60 min after applying the allocated first inflation strategy. At study completion molecular and histological markers of lung injury were analyzed. The time to SI volume equilibrium, and resultant volume, were highly variable; mean (SD) 55 (34) s, coefficient of variability 59%. SIplat and SIlong resulted in better lung mechanics, gas exchange and lower ventilator settings than both no-SI and SI30. At 60 min, alveolar-arterial difference in oxygen was a mean (95% confidence interval) 130 (13, 249) higher in SI30 vs. SIlong group (two-way ANOVA). These differences were due to better spatiotemporal aeration and tidal ventilation, although all groups showed redistribution of aeration towards the nondependent lung by 60 min. Histological lung injury scores mirrored spatiotemporal change in aeration and were greatest in SI30 group (P < 0.01, Kruskal-Wallis test). An individualized volume-response approach to SI was effective in optimizing aeration, homogeneous tidal ventilation, and respiratory outcomes, while an inadequate SI duration had no benefit over positive pressure ventilation alone.
The electrical resistivity distribution at the base of La Soufrière of Guadeloupe lava dome is reconstructed by using transmission electrical resistivity data obtained by injecting an electrical ...current between two electrodes located on opposite sides of the volcano. Several pairs of injection electrodes are used in order to constitute a data set spanning the whole range of azimuths, and the electrical potential is measured along a cable covering an angular sector of ≈120° along the basis of the dome. The data are inverted to perform a slice electrical resistivity tomography (SERT) with specific functions implemented in the EIDORS open source package dedicated to electrical impedance tomography applied to medicine and geophysics. The resulting image shows the presence of highly conductive regions separated by resistive ridges. The conductive regions correspond to unconsolidated material saturated by hydrothermal fluids. Two of them are associated with partial flank collapses and may represent large reservoirs that could have played an important role during past eruptive events. The resistive ridges may represent massive andesite and are expected to constitute hydraulic barriers.
Respiratory transition at birth involves rapidly clearing fetal lung liquid and preventing efflux back into the lung while aeration is established. We have developed a sustained inflation (SI
) ...individualized to volume response and a dynamic tidal positive end-expiratory pressure (PEEP) (open lung volume, OLV) strategy that both enhance this process. We aimed to compare the effect of each with a group managed with PEEP of 8 cmH
O and no recruitment maneuver (No-RM), on gas exchange, lung mechanics, spatiotemporal aeration, and lung injury in 127 ± 1 day preterm lambs. Forty-eight fetal-instrumented lambs exposed to antenatal steroids were ventilated for 60 min after application of the allocated strategy. Spatiotemporal aeration and lung mechanics were measured with electrical impedance tomography and forced-oscillation, respectively. At study completion, molecular and histological markers of lung injury were analyzed. Mean (SD) aeration at the end of the SI
and OLV groups was 32 (22) and 38 (15) ml/kg, compared with 17 (10) ml/kg (180 s) in the No-RM (P = 0.024, 1-way ANOVA). This translated into better oxygenation at 60 min (P = 0.047; 2-way ANOVA) resulting from better distal lung tissue aeration in SI
and OLV. There was no difference in lung injury. Neither SI
nor OLV achieved homogeneous aeration. Histological injury and mRNA biomarker upregulation were more likely in the regions with better initial aeration, suggesting volutrauma. Tidal ventilation or an SI achieves similar aeration if optimized, suggesting that preventing fluid efflux after lung liquid clearance is at least as important as fluid clearance during the initial inflation at birth.
: Various imaging modalities can be used in addition to white light (WL) to improve detection of bladder cancer (BC).
: To use real-time multispectral imaging (rMSI) during urethrocystoscopy to ...combine different imaging modalities to achieve multiparametric cystoscopy (MPC).
: The rMSI system consisted of a camera with a spectral filter, a multi-LED light source, a microcontroller, and a computer for display and data acquisition. MSI with this system was achieved via temporal multiplexing.
: MPC was performed in ten patients with a diagnosed bladder tumor.
: We gathered evidence to prove the feasibility of our approach. In addition, experienced urologists performed post-interventional evaluation of images of individual lesions. Images were independently rated in a semiquantitative manner for each modality. A statistical model was built for pairwise comparisons across modalities.
: Overall, 31 lesions were detected using the rMSI set-up. Histopathology revealed malignancy in 27 lesions. All lesions could be visualized simultaneously in five modalities: WL, enhanced vascular contrast (EVC), blue light fluorescence, protoporphyrin IX fluorescence, and autofluorescence. EVC and photodynamic diagnosis images were merged in real time into one MP image. Using the recorded images, two observers identified all malignant lesions via MPC, whereas the single modalities did not arouse substantial suspicion for some lesions. The MP images of malignant lesions were rated significantly more suspicious than the images from single imaging modalities.
: We demonstrated for the first time the application of rMSI in endourology and we established MPC for detection of BC. This approach allows existing imaging modalities to be combined, and it may significantly improve the detection of bladder cancer.
: Real-time multispectral imaging was successfully used to combine different imaging aids for more comprehensive illustration of bladder tumors for surgeons. In the future, this technique may allow better detection of bladder tumors and more complete endoscopic resection in cases of cancer.
Real-time multispectral imaging can be used to simultaneously visualize different imaging modalities for bladder cancer detection. Their combination and overlay in one endoscopic image channel allow multiparametric cystoscopy. This technology may significantly improve endoscopic detection of bladder cancer.
Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ...ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (rs = 0.89 right, rs = 0.90 left lung) and after local injury (rs = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%±1.1% by EIT and 5.4%±1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level.
Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the ...assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.