CSES (China Seismo-Electromagnetic Satellite) is a Chinese–Italian scientific space mission dedicated to monitor the variations of the main parameters of the topside ionosphere (electric and magnetic ...fields, plasma parameters, charge particle fluxes) caused by either natural emitters – especially earthquakes – or artificial ones.
The CSES satellite was successfully launched from the Jiuquan Satellite Launch Center located in the west of Inner Mongolia on February 2nd, 2018, and it is now orbiting under nominal conditions. The expected mission lifetime amounts to 5 years. CSES is the first element of a multi-satellite monitoring system; several satellites are scheduled for the next few years.
The High-Energy Particle Detector (HEPD) is the main contribution of the Italian collaboration to the mission. It was designed and built in order to detect electrons in the energy range between 3 and 100 MeV, protons between 30 and 200 MeV, and light nuclei in the MeV energy window.
The electronics of the detector was designed following stringent requirements on mechanical and thermal stability, power consumption, radiation hardness and double redundancy. The system successfully went through the space qualification tests. In this paper, we describe the HEPD electronics, the space qualification tests performed before launch, and the in-flight performance of the detector.
CSES (China Seismo-Electromagnetic Satellite) is a Chinese-Italian space mission dedicated to monitoring of variations of the electromagnetic field and waves, plasma parameters, and particle fluxes ...induced by natural sources and artificial emitters in the near-Earth space. The satellite was launched from the Jiuquan Satellite Launch Center in the Gobi desert (Inner Mongolia, China) on 2, 2018. The expected mission lifetime amounts to 5 years.
The Italian contribution to the mission includes the design and construction of the High-Energy Particle Detector (HEPD), aimed to detect electrons in the energy range between 3 and 100 MeV and protons between 30 and 200 MeV, as well as light nuclei in the MeV energy range.
In this paper, we describe the calibration procedures applied to HEPD based on data acquired during two tests at accelerator laboratories, which were performed on HEPD Flight Model prior to the delivery to China for final integration. An additional acquisition of cosmic muons was performed in order to better characterize the detector response before launch.
Diabetic kidney disease is a major cause of premature mortality in type 2 diabetes mellitus (T2DM). Worsening insulin sensitivity independent of glycemic control may contribute to the development of ...diabetic kidney disease. We investigated the longitudinal association of insulin sensitivity with hyperfiltration and increased albumin excretion in adolescents with T2DM.
Observational prospective cohort study.
532 TODAY (Treatment Options for Type 2 Diabetes in Adolescents and Youth) participants aged 12 to 17 years with T2DM duration less than 2 years at baseline. The TODAY Study was a multicenter randomized clinical trial that examined the efficacy of 3 treatment regimens (metformin monotherapy, metformin plus rosiglitazone, or metformin plus an intensive lifestyle intervention program) to achieve durable glycemic control.
Natural log–transformed estimated insulin sensitivity (reciprocal of fasting insulin), hemoglobin A1c concentration, age, race-ethnicity, treatment group, body mass index, loss of glycemic control, and hypertension.
Hyperfiltration was defined as 99th percentile or higher of estimated glomerular filtration rate (≥140mL/min/1.73m2) when referenced to healthy adolescents (NHANES 1999-2002) and albumin-creatinine ratio ≥ 30μg/mg at 3 consecutive annual visits.
Hyperfiltration was observed in 7.0% of participants at baseline and in 13.3% by 5 years, with a cumulative incidence of 5.0% over 5 years. The prevalence of increased albumin excretion was 6% at baseline and 18% by 5 years, with a cumulative incidence of 13.4%. There was an 8% increase in risk for hyperfiltration per 10% lower estimated insulin sensitivity in unadjusted and adjusted models (P=0.01). Increased albumin excretion was associated with hemoglobin A1c concentration, but not estimated insulin sensitivity.
Longer follow-up is needed to capture the transition from hyperfiltration to rapid glomerular filtration rate decline in youth-onset T2DM.
Lower estimated insulin sensitivity was associated with risk for hyperfiltration over time, whereas increased albumin excretion was associated with hyperglycemia in youth-onset T2DM.
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the ...full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitization of the chamber signals will be of around 1 ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.
Obese youth without diabetes with monophasic oral glucose tolerance test (OGTT) glucose response curves have lower insulin sensitivity and impaired β-cell function compared with those with biphasic ...curves. The OGTT glucose response curve has not been studied in youth-onset type 2 diabetes. Here we test the hypothesis that the OGTT glucose response curve at randomization in youth in the TODAY (Treatment Options for Type 2 Diabetes in Adolescents and Youth) study forecasts heightened glycemic failure rates and accelerated decline in β-cell function.
OGTTs (
= 662) performed at randomization were categorized as monophasic, biphasic, or incessant increase. Demographics, insulin sensitivity (1/fasting insulin), C-peptide index (△C
/△G
), and β-cell function relative to insulin sensitivity (oral disposition index oDI) were compared among the three groups.
At randomization, 21.7% had incessant increase, 68.6% monophasic, and 9.7% biphasic glucose response curves. The incessant increase group had similar insulin sensitivity but significantly lower C-peptide index and lower oDI, despite similar diabetes duration, compared with the other two groups. Glycemic failure rates were higher in the incessant increase group (58.3%) versus the monophasic group (42.3%) versus the biphasic group (39.1%) (
< 0.0001). The 6-month decline in C-peptide index (32.8% vs. 18.1% vs. 13.2%) and oDI (32.2% vs. 11.6% vs. 9.1%) was greatest in incessant increase versus monophasic and biphasic with no difference in insulin sensitivity.
In the TODAY study cohort, an incessant increase in the OGTT glucose response curve at randomization reflects reduced β-cell function and foretells increased glycemic failure rates with accelerated deterioration in β-cell function independent of diabetes duration and treatment assignment compared with monophasic and biphasic curves. The shape of the OGTT glucose response curve could be a metabolic biomarker prognosticating the response to therapy in youth with type 2 diabetes.
Data regarding atherogenic dyslipidemia and the inflammation profile in youth with type 2 diabetes is limited and the effect of insulin therapy on these variables has not previously been studied in ...youth. We determined the impact of insulin therapy on lipid and inflammatory markers in youth with poorly controlled type 2 diabetes.
In the Treatment Options for type 2 Diabetes in Adolescents and Youth (TODAY) multicenter trial, 285 participants failed to sustain glycemic control on randomized treatment (primary outcome, glycated hemoglobin A1c HbA1c at ≥8% for 6 months); 363 maintained glycemic control (never reached primary outcome). Statins were used for a low-density lipoprotein cholesterol of ≥130 mg/dL. Upon reaching the primary outcome, insulin was started. Changes in lipids and inflammatory markers (slopes over time) were examined.
Progression of dyslipidemia was related to glycemic control. In those with the primary outcome, insulin therapy impacted HbA1c modestly, and dampened the increase in total cholesterol, low-density lipoprotein cholesterol, and total apolipoprotein B, although statin use increased from 8.6% to 22% year after the primary outcome. The increase in triglycerides and plasma nonesterified fatty acids stabilized after insulin was started, independent of HbA1c. There was an increase in high-sensitivity C-reactive protein that continued after insulin initiation, related to HbA1c and percent overweight.
Worsening dyslipidemia and inflammation over time raise concern regarding premature development of atherosclerosis in youth with type 2 diabetes. Insulin therapy has a limited benefit in the absence of glycemic control. Strategies to achieve better glycemic control are needed.
ClinicalTrials.gov: NCT00081328.
This research develops a distinct method for obtaining of thin films of CdS and CdTe with vertical nanostructure morphology grown at low temperatures on the substrate of about 100 °C, were obtained ...by RF sputtering and sublimation from a vapor effusion source, respectively, both methods were combined with the glancing angle deposition technique. The CdS thin film exhibited a hexagonal structure with preferential plane orientation (002) under compressive stress and a crystallite size of approximately 45 nm. The CdTe film showed a cubic Zinc-Blende structure with an expansive lattice of the unit cell and with preferential plane orientation (111). The size of the crystallites in CdTe was approximately 56 nm. Scanning electron microscopy showed porous nanocolumn structures with vertical nanorods with a width of approximately 16 nm for the CdS and 80 nm for the CdTe, respectively with thicknesses of approximately 335 nm for the CdS and 1330 nm for the CdTe. Using open-source software ImageJ obtained a porosity measurement of approximately 10.4% for CdS and 9.4% for CdTe, respectively. The bandgap energy of the CdS and CdTe thin films was 2.47 eV and 2.51 eV, respectively. The refractive index was 2.5 for CdS and 3.5 for CdTe, respectively. The Urbach energy of the CdS and CdTe was 146 meV and 62 meV respectively. Our results are optimal for possible applications in photovoltaic devices, especially in solar cells and flexible solar cells.
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor ...detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor ...detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
To examine cardiac biomarkers over time in youth-onset type 2 diabetes, and relate serum concentrations to cardiovascular disease risk factors, and left ventricular structure and function.
TODAY ...(Treatment Options for type 2 Diabetes in Adolescents and Youth) was a multicenter randomized trial of 3 treatments including 521 participants with type 2 diabetes, aged 10-17 years, and with 2-6 years of follow-up. Participants were 36% male, obese, and ethnically diverse. Annual serum concentrations of brain natriuretic peptide, troponin, tumor necrosis factor (TNF)-α, receptors 1 and 2 were related to blood pressure, body mass index, hemoglobin A1c, and left ventricular ejection fraction, diastolic function, relative wall thickness, and mass.
Elevated concentrations of brain natriuretic peptide (≥100 pg/mL), TNF-α (≥5.6 pg/mL) and troponin (≥0.01 ng/mL), were present in 17.8%, 18.3%, and 34.2% of the cohort, respectively, at baseline, and in 15.4%, 17.1%, and 31.1% at the end of the study, with wide variability over time, without persistence in individuals or clear relationship to glycemia or cardiovascular structure/function. TNF receptors concentrations were increased at baseline and not significantly different from end-of-study concentrations. Adverse echocardiographic measures were more likely in the highest TNF receptor tertile (all P < .05): higher left ventricular mass (39.3 ± 9.0 g/m2.7), left atrial internal dimension (3.7 ± 0.4 cm) and E/Em ratio, a measure of diastolic dysfunction (6.2 ± 1.9). After adjustment for body mass index, these relationships were no longer significant.
Elevated serum concentrations of cardiac biomarkers were common in youth with type 2 diabetes, but their clinical significance is unclear and will require further long-term study.
ClinicalTrials.govNCT00081328.