Background Contemporary EUS-guided FNA techniques involve the use of a needle, with an air column within the lumen, with or without suction. We describe a novel technique with an aim to improve the ...quality of the aspirate. Objective To compare a novel “wet suction” technique (WEST) with the conventional FNA technique (CFNAT) of EUS-guided FNA using a 22-gauge FNA needle. Design Prospective, single-blind, and randomized trial. Setting Two large tertiary-care hospitals. Patients All consecutive adult patients presenting for EUS with possible FNA of solid lesions were offered the chance to participate in the study. Methods All lesions were sampled with the same needle by using alternating techniques. Patients were randomized to the WEST versus the CFNAT for the first pass. If the first pass was made with the WEST, the second pass was made with the CFNAT, and subsequent passes were made in an alternating manner by using the same sequence. All FNAs were performed using 22-gauge needles. Main Outcome Measurements Specimen adequacy, cellularity, and blood contamination of EUS-guided FNA aspirates graded on a predefined scale. Results The WEST yielded significantly higher cellularity in a cell block compared with the CFNAT, with a mean cellularity score of 1.82 ± 0.76 versus 1.45 ± 0.768 ( P < .0003). The WEST cell block resulted in a significantly better specimen adequacy of 85.5% versus 75.2% ( P < .035). There was no difference in the amount of blood contamination between the 2 techniques. Limitations Lack of cross check and grading by a second cytopathologist. Conclusion The novel WEST resulted in significantly better cellularity and specimen adequacy in cell blocks of EUS-guided FNA aspirate of solid lesions than the CFNAT.
Background There is increasing demand for colonoscopy quality measures for procedures performed in ambulatory surgery centers. Benchmarks such as adenoma detection rate (ADR) are traditionally ...reported as static, one-dimensional point estimates at a provider or practice level. Objective To evaluate 6-year variability of ADRs for 370 gastroenterologists from across the nation. Design Observational cross-sectional analysis. Setting Collaborative quality metrics database from 2007 to 2012. Patients Patients who underwent colonoscopies in ambulatory surgery centers. Interventions Colonoscopy. Main Outcome Measurements The number of colonoscopies with an adenomatous polyp divided by the total number of colonoscopies (ADR-T), inclusive of indication and patient's sex. Results Data from 368,157 colonoscopies were included for analysis from 11 practices. Three practice sites (5, 8, and 10) were significantly above and 2 sites (3, 7) were significantly below mean ADR-T, with a 95% confidence interval (CI). High-performing sites had 9.0% higher ADR-T than sites belonging to the lowest quartile ( P < .001). The mean ADR-T remained stable for 9 of 11 sites. Regression analysis showed that the 2 practice sites where ADR-T varied had significant improvements in ADR-T during the 6-year period. For each, mean ADR-T improved an average of 0.5% per quarter for site 2 ( P = .001) and site 3 ( P = .021), which were average and low performers, respectively. Limitations Summary-level data, which does not allow cross-reference of variables at an individual level. Conclusion We found performance disparities among practice sites remaining relatively consistent over a 6-year period. The ability of certain sites to sustain their high-performance over 6 years suggests that further research is needed to identify key organizational processes and physician incentives that improve the quality of colonoscopy.