The technological prototype of the CALICE highly granular silicon–tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon ...sensors. Each layer comprised four sensors, with each sensor containing an array of 256 5.5×5.5 mm2 silicon PIN diodes. The four sensors covered a total area of 18 × 18 cm and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.
Abstract
The SuperFGD detector will be a novel and important upgrade to the ND280 near detector for both the T2K and Hyper-Kamiokande projects. The main goal of the ND280 upgrade is to reduce ...systematic uncertainties associated with neutrino flux and cross-section modeling for future studies of neutrino oscillations using the T2K and Hyper-Kamiokande experiments. The upgraded ND280 detector will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and for the first time, event-by event measurements of neutron kinematics. Precisely understanding the time resolution is critical for the neutron energy measurements and hence an important factor in reducing the systematic uncertainties. In this paper we present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm
3
) readout with 1728 wavelength-shifting (WLS) fibers along the three orthogonal directions. We used data from a muon beam exposure at CERN. A time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for time-walk effects. The time resolution improves with increasing energy deposited in a scintillator cube,
improving to 0.87 ns for large pulses.
Averaging two readout channels for one scintillator cube further improves the time resolution to 0.68 ns implying that signals in different channels are not synchronous. In addition the contribution from the time sampling interval of 2.5 ns is averaged as well. Most importantly, averaging time values from N channels improves the time resolution by ∼ 1/√(N). For example, averaging the time from 2 scintillator cubes with 2 fibers each improves the time resolution to 0.47 ns which is much better than the intrinsic electronics time resolution of 0.72 ns in one channel due to the 2.5 ns sampling window. This indicates that a very good time resolution should be achievable for neutrons since neutron recoils typically interact with several scintillator cubes and in addition produce larger signal amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope in which the contribution from the electronics time sampling window was removed demonstrated that the time resolution obtained with the muon beam is not far from the theoretical limit. The intrinsic time resolution of a scintillator cube and one WLS fiber is about 0.67 ns for signals of 56 photo electrons which is typical for minimum ionizing particles.
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity ...calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80 GeV with 10 GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams. The rejection power of the new method is estimated to be as high as 99.0% for the muons and 99.4% for the electrons associated to a pion selection efficiency of about 95.0%.
The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section ...modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm\(^3\)) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by \(\sim 1/\sqrt{N}\). Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon ...sensors. Each layer comprised four sensors, with each sensor containing an array of 256 \(5.5\times5.5\) mm\(^2\) silicon PIN diodes. The four sensors covered a total area of \(18\times18\) cm\(^2\), and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity ...calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
The importance of natural reinforced bio-composite materials with desirable properties such as high modulus-to-weight ratio, good impact resistance, and the ability to be easily repaired is crucial ...in the industry. A woven flax/Elium® thermoplastic bio-composite is manufactured to challenge these needs. Elium® is the only resin that permits the manufacture of large parts with thermoset-like processes, as Liquid Resin Infusion presented in that work. The paper highlights the influence of stacking fibre orientation, moisture absorption, and repair aptitude on its impact resistance. An instrumented drop tower was needed to conduct low-velocity impact tests at several energies and high-speed image coupled with microscopic observations was used to assess the damage evolution. The impact resistance was improved for the dry (0/90)6 orientation, but moisture absorption decreased its impact peak force by 20%. A three-point bending test was preferred to compression after impact for studying the residual properties after impact. The bio-composites with (±45)6 orientation showed higher impact residual performance than the (0/90)6 orientation, and corresponded to the reduction of maximum bending force by 20% than that of the reference. In addition, a thermo-compression process was applied to repair the impacted plates and conduct multiple impact/repair cycles which showed a significant recovery of stiffness and maximum impact force at 4J on (0/90)6 plates, highlighting their potential for repair in the automotive and marine industries.
In this placebo-controlled phase II randomized clinical trial, 103 human immunodeficiency virus type 1 (HIV-1)-infected patients under cART (combined antiretroviral treatment) were randomized 2:1 to ...receive either 3 doses of DNA GTU-MultiHIV B (coding for Rev, Nef, Tat, Gag, and gp160) at week 0 (W0), W4, and W12, followed by 2 doses of LIPO-5 vaccine containing long peptides from Gag, Pol, and Nef at W20 and W24, or placebo. Analytical treatment interruption (ATI) was performed between W36 to W48. At W28, vaccinees experienced an increase in functional CD4
T-cell responses (
< 0.001 for each cytokine compared to W0) measured, predominantly against Gag and Pol/Env, and an increase in HIV-specific CD8
T cells producing interleukin 2 (IL-2) and tumor necrosis factor alpha (TNF-α) (
= 0.001 and 0.013, respectively), predominantly against Pol/Env and Nef. However, analysis of T-cell subsets by mass cytometry in a subpopulation showed an increase in the W28/W0 ratio for memory CD8
T cells coexpressing exhaustion and senescence markers such as PD-1/TIGIT (
= 0.004) and CD27/CD57 (
= 0.044) in vaccinees compared to the placebo group. During ATI, all patients experienced viral rebound, with the maximum observed HIV RNA level at W42 (median, 4.63 log
copies cp/ml; interquartile range IQR, 4.00 to 5.09), without any difference between arms. No patient resumed cART for CD4 cell count drop. Globally, the vaccine strategy was safe. However, a secondary HIV transmission during ATI was observed. These data show that the prime-boost combination of DNA and LIPO-5 vaccines elicited broad and polyfunctional T cells. The contrast between the quality of immune responses and the lack of potent viral control underscores the need for combined immunomodulatory strategies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01492985.)
In this placebo-controlled phase II randomized clinical trial, we evaluated the safety and immunogenicity of a therapeutic prime-boost vaccine strategy using a recombinant DNA vaccine (GTU-MultiHIV B clade) followed by a boost vaccination with a lipopeptide vaccine (HIV-LIPO-5) in HIV-infected patients on combined antiretroviral therapy. We show here that this prime-boost strategy is well tolerated, consistently with previous studies in HIV-1-infected individuals and healthy volunteers who received each vaccine component individually. Compared to the placebo group, vaccinees elicited strong and polyfunctional HIV-specific CD4
and CD8
T-cell responses. However, these immune responses presented some qualitative defects and were not able to control viremia following antiretroviral treatment interruption, as no difference in HIV viral rebound was observed in the vaccine and placebo groups. Several lessons were learned from these results, pointing out the urgent need to combine vaccine strategies with other immune-based interventions.
Effect of manufacturing on impact damage behaviour was investigated in typical marine composites of E-glass fibre/polyester/PVC foam core sandwich structures. Face/core bonding was performed using ...two different adhesives and the matrix resin. Low velocity impact response of the sandwich plates was investigated using an instrumented impact drop tower. Impact damage size was estimated by visual inspection or by the ultrasonic C-scan. Failure characteristics indicate that, in terms of the frequency of core fracture, wet-lay-up process is superior to adhesive bonding of the face to the foam core. Damage initiation and failure mechanisms were recorded by high-speed photography and related to the load–time plots. The type of face core bonding did not affect the delamination threshold load (DTL) of the sandwich structure, which depends on the properties of the face laminate. DTL was found ca. 2.5
kN. Morphology of the face/core interfaces was examined using a SEM microscope.