The large volume of adult living donor liver transplantations (ALDLTs) at our center affords a unique opportunity to examine the impact of acute‐on‐chronic liver failure (ACLF) among high–Model for ...End‐Stage Liver Disease MELD score patients. From February 1998 to March 2010, 1958 cirrhotic recipients were analyzed to study the relationship between MELD scores and ALDLT outcomes. A total of 327 high‐MELD score recipients were categorized into ACLF and non‐ACLF groups, and their outcomes were compared. The 5‐year graft and patient survival in the high‐MELD group were 75.2% and 76.4%, respectively, which were significantly worse than the low and intermediate MELD groups. The presence of ACLF associated with higher MELD scores appeared to be the dominant factor responsible for the inferior results of patients with MELD score of 30–34 points. The 5‐year graft survivals in the ACLF group was 70.5% and in the non‐ACLF group it was 81.0% (p = 0.035). Therefore, ALDLT should be performed as soon as possible in high‐MELD score patients prior to ACLF development. Moreover, ACLF patients should be separately categorized when analyzing the outcomes of ALDLT. ALDLT for ACLF patients should not be discouraged because favorable outcomes can be expected through timely ALDLT and comprehensive management.
While adult living donor liver transplantation should be performed as soon as possible before acute‐on‐chronic liver failure develops, it should not be discouraged for patients with acute‐on‐chronic liver failure since timely transplantation and comprehensive management can bring a favorable outcome.
ABO incompatibility is no longer considered a contraindication for adult living donor liver transplantation (ALDLT) due to various strategies to overcome the ABO blood group barrier. We report the ...largest single‐center experience of ABO‐incompatible (ABOi) ALDLT in 235 adult patients. The desensitization protocol included a single dose of rituximab and total plasma exchange. In addition, local graft infusion therapy, cyclophosphamide, or splenectomy was used for a certain time period, but these treatments were eventually discontinued due to adverse events. There were three cases (1.3%) of in‐hospital mortality. The cumulative 3‐year graft and patient survival rates were 89.2% and 92.3%, respectively, and were comparable to those of the ABO‐compatible group (n = 1301). Despite promising survival outcomes, 17 patients (7.2%) experienced antibody‐mediated rejection that manifested as diffuse intrahepatic biliary stricture; six cases required retransplantation, and three patients died. ABOi ALDLT is a feasible method for expanding a living liver donor pool, but the efficacy of the desensitization protocol in targeting B cell immunity should be optimized.
This article presents the clinical results of ABO‐incompatible adult living donor liver transplantation in a single institution.
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years of COSINE-100 data with a total exposure of 97.7 kg yr. The COSINE-100 experiment, consisting of 106 kg ...of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2-6 keV energy region of interest. Using a χ-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092±0.0067 cpd/kg/keV and 127.2±45.9 d, respectively.
We aim to summarize the available evidence on the diagnostic accuracy of imaging (index test) compared to surgery (reference test) for identifying lumbar disc herniation (LDH) in adult patients.For ...this systematic review we searched MEDLINE, EMBASE and CINAHL (June 2017) for studies that assessed the diagnostic accuracy of imaging for LDH in adult patients with low back pain and surgery as the reference standard. Two review authors independently selected studies, extracted data and assessed risk of bias. We calculated summary estimates of sensitivity and specificity using bivariate analysis, generated linked ROC plots in case of direct comparison of diagnostic imaging tests and assessed the quality of evidence using the GRADE-approach.We found 14 studies, all but one done before 1995, including 940 patients. Nine studies investigated Computed Tomography (CT), eight myelography and six Magnetic Resonance Imaging (MRI). The prior probability of LDH varied from 48.6 to 98.7%. The summary estimates for MRI and myelography were comparable with CT (sensitivity: 81.3% (95%CI 72.3-87.7%) and specificity: 77.1% (95%CI 61.9-87.5%)). The quality of evidence was moderate to very low.
The diagnostic accuracy of CT, myelography and MRI of today is unknown, as we found no studies evaluating today's more advanced imaging techniques. Concerning the older techniques we found moderate diagnostic accuracy for all CT, myelography and MRI, indicating a large proportion of false positives and negatives.
Initial performance of the COSINE-100 experiment Adhikari, G.; Adhikari, P.; de Souza, E. Barbosa ...
European physical journal. C, Particles and fields,
02/2018, Letnik:
78, Številka:
2
Journal Article
Recenzirano
Odprti dostop
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer ...of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least 2 years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Despite aggressive multimodal treatment, glioblastoma (GBM), a grade IV primary brain tumor, still portends a poor prognosis with a median overall survival of 12-16 months. The complexity of GBM ...treatment mainly lies in the inter- and intra-tumoral heterogeneity, which largely contributes to the treatment-refractory and recurrent nature of GBM. By paving the road towards the development of personalized medicine for GBM patients, the cancer genome atlas classification scheme of GBM into distinct transcriptional subtypes has been considered an invaluable approach to overcoming this heterogeneity. Among the identified transcriptional subtypes, the mesenchymal subtype has been found associated with more aggressive, invasive, angiogenic, hypoxic, necrotic, inflammatory, and multitherapy-resistant features than other transcriptional subtypes. Accordingly, mesenchymal GBM patients were found to exhibit worse prognosis than other subtypes when patients with high transcriptional heterogeneity were excluded. Furthermore, identification of the master mesenchymal regulators and their downstream signaling pathways has not only increased our understanding of the complex regulatory transcriptional networks of mesenchymal GBM, but also has generated a list of potent inhibitors for clinical trials. Importantly, the mesenchymal transition of GBM has been found to be tightly associated with treatment-induced phenotypic changes in recurrence. Together, these findings indicate that elucidating the governing and plastic transcriptomic natures of mesenchymal GBM is critical in order to develop novel and selective therapeutic strategies that can improve both patient care and clinical outcomes. Thus, the focus of our review will be on the recent advances in the understanding of the transcriptome of mesenchymal GBM and discuss microenvironmental, metabolic, and treatment-related factors as critical components through which the mesenchymal signature may be acquired. We also take into consideration the transcriptomic plasticity of GBM to discuss the future perspectives in employing selective therapeutic strategies against mesenchymal GBM.
The CHARA Array is a six 1 m telescope optical/IR interferometric array located on Mount Wilson, California, designed and built by the Center for High Angular Resolution Astronomy of Georgia State ...University. In this paper we describe the main elements of the Array hardware and software control systems, as well as the data reduction methods currently being used. Our plans for upgrades in the near future are also described.
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. Building on experience accumulated ...during the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200 kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRA annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contamination from radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1 count/day/keV/kg for recoil energies around 2 keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7
σ
test of the DAMA/LIBRA signature would be possible with a 600 kg year exposure with this system.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals ...we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2–6) keV energy interval. The dominant contributors in this energy region are found to be
210
Pb and
3
H.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK