An intense positron sources is a demanding element in the design of future lepton colliders. A crystal-based hybrid positron source could be an alternative to a more conventional scheme based on the ...electron conversion into positron in a thick amorphous target. The conceptual idea of the hybrid source is to have two separate objects, a photon radiator and a photon-to-positron converter target. In such a scheme an electron beam crosses a thin axially oriented crystal with the emission of a channeling radiation, characterized by a considerably larger amount of photons if compared to Bremsstrahlung. The net result is an increase in the number of produced positrons at the converter target. In this paper we present the results of a beam test conducted at the DESY TB 21 with 5.6 GeV electron beam and a crystalline tungsten radiator. Experimental data clearly highlight an increased production of photons and they are critically compared with the outcomes of novel method to simulate the number of radiated photons, showing a very good agreement. Strong of this, the developed simulation tool has been exploited to design a simple scheme for a positron source based on oriented crystal, demonstrating the advantages in terms of reduction of both deposited energy and the peak energy deposition density if compared to conventional sources. The presented work opens the way for a realistic and detailed design of a hybrid crystal-based positron source for future lepton colliders.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
A proof-of-principle experimental setup for the extraction of 6 GeV electrons from the DESY II Booster Synchrotron using the channeling effect in a bent crystal is elaborated. Various aspects of the ...experimental setup were investigated in detail, such as the particle beam dynamics during the extraction process, the manufacturing and characterization of bent crystals, and the detection of the extracted beam. In order to optimize the crystal geometry, the overall process of beam extraction was simulated, taking into account the influence of radiation energy losses. As result it is concluded that the multi-turn electron beam extraction efficiency can reach up to 16%. In principle this crystal-based beam extraction technique can be applied at any electron synchrotron in order to provide multi-GeV electron beams in a parasitic mode. This technique will allow to supply fixed-target experiments by intense high-quality monoenergetic electron beams. Furthermore, electron/positron crystal-based extraction from future lepton colliders may provide an access to unique experimental conditions for ultra-high energy fixed-target experiments including searches for new physics beyond the Standard Model.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not ...aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of the CERN Super Proton Synchrotron were critically compared to Monte Carlo simulations based on the Baier-Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of 5 in the case of beam alignment with the 001 crystal axes. The observed effect opens the way to the realization of compact electromagnetic calorimeters or detectors based on oriented scintillator crystals in which the amount of material can be strongly reduced with respect to the state of the art. These devices could have relevant applications in fixed-target experiments, as well as in satellite-borne γ telescopes.
We have observed a significant enhancement in the energy deposition by 25–
100
GeV
photons in a
1
cm
thick tungsten crystal oriented along its
⟨
111
⟩
lattice axes. At
100
GeV
, this enhancement, ...with respect to the value observed without axial alignment, is more than twofold. This effect, together with the measured huge increase in secondary particle generation is ascribed to the acceleration of the electromagnetic shower development by the strong axial electric field. The experimental results have been critically compared with a newly developed Monte Carlo adapted for use with crystals of multi-
X
0
thickness. The results presented in this paper may prove to be of significant interest for the development of high-performance photon absorbers and highly compact electromagnetic calorimeters and beam dumps for use at the energy and intensity frontiers.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can ...be exploited to achieve an outstanding performance boost in terms of compactness and energy resolution. In fact, it was recently demonstrated by the AXIAL/ELIOT experiments that a strong reduction in the radiation length inside PWO, and a subsequent enhancement in the scintillation light emitted per unit thickness, are attained when the incident particle trajectory is aligned with a crystal axis within ~ 1°. A SiPM-based system has been developed to directly probe this remarkable effect by measuring the scintillation light emitted by a PWO sample. The same concept could be applied to full-scale detectors that would feature a design significantly more compact than currently achievable and unparalleled resolution in the range of interest for present and future experiments.
The method of relativistic molecular dynamics is applied for accurate computational modeling and numerical analysis of the channelling phenomena for 855 MeV electrons in bent oriented silicon (111) ...crystal. Special attention is devoted to the transition from the axial channelling regime to the planar one in the course of the crystal rotation with respect to the incident beam. Distribution in the deflection angle of electrons and spectral distribution of the radiation emitted are analyzed in detail. The results of calculations are compared with the experimental data collected at the MAinzer MIctrotron facility.
Progress in high-energy physics has been closely tied to the development of high-performance electromagnetic calorimeters. Recent experiments have demonstrated the possibility to significantly ...accelerate the development of electromagnetic showers inside scintillating crystals typically used in homogeneous calorimeters based on scintillating crystals when the incident beam is aligned with a crystallographic axis to within a few mrad. In particular, a reduction of the radiation length has been measured when ultrarelativistic electron and photon beams were incident on a high-
Z
scintillator crystal along one of its main axes. Here, we propose the possibility to exploit this physical effect for the design of a new type of compact e.m. calorimeter, based on oriented ultra-fast lead tungstate (PWO-UF) crystals, with a significant reduction in the depth needed to contain electromagnetic showers produced by high-energy particles with respect to the state-of-the-art. We report results from tests of the crystallographic quality of PWO-UF samples via high-resolution X-ray diffraction and photoelastic analysis. We then describe a proof-of-concept calorimeter geometry defined with a Geant4 model including the shower development in oriented crystals. Finally, we discuss the experimental techniques needed for the realization of a matrix of scintillator crystals oriented along a specific crystallographic direction. Since the angular acceptance for e.m. shower acceleration depends little on the particle energy, while the decrease of the shower length remains pronounced at very high energy, an oriented crystal calorimeter will open the way for applications at the maximum energies achievable in current and future experiments. Such applications span from forward calorimeters, to compact beam dumps for the search for light dark matter, to source-pointing space-borne
γ
-ray telescopes, to decrease the size and the cost of the calorimeter needed to fully contain e.m. showers initiated by GeV to TeV particles.
FCC Physics Opportunities Altmannshofer, W.; Arsenyev, S. A.; Aune, S. ...
The European physical journal. C, Particles and fields,
2019, Letnik:
79, Številka:
6
Journal Article, Publication
Recenzirano
Odprti dostop
We review the physics opportunities of the Future Circular Collider, covering its e
+
e
-
, pp, ep and heavy ion programmes. We describe the measurement capabilities of each FCC component, addressing ...the study of electroweak, Higgs and strong interactions, the top quark and flavour, as well as phenomena beyond the Standard Model. We highlight the synergy and complementarity of the different colliders, which will contribute to a uniquely coherent and ambitious research programme, providing an unmatchable combination of precision and sensitivity to new physics.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
FCC-ee: The Lepton Collider Altmannshofer, W.; Arsenyev, S. A.; Azatov, A. ...
The European physical journal. ST, Special topics,
06/2019, Letnik:
228, Številka:
2
Journal Article, Publication
Recenzirano
Odprti dostop
In response to the 2013 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) study was launched, as an international collaboration hosted by CERN. This study ...covers a highest-luminosity high-energy lepton collider (FCC-ee) and an energy-frontier hadron collider (FCC-hh), which could, successively, be installed in the same 100 km tunnel. The scientific capabilities of the integrated FCC programme would serve the worldwide community throughout the 21st century. The FCC study also investigates an LHC energy upgrade, using FCC-hh technology. This document constitutes the second volume of the FCC Conceptual Design Report, devoted to the electron-positron collider FCC-ee. After summarizing the physics discovery opportunities, it presents the accelerator design, performance reach, a staged operation scenario, the underlying technologies, civil engineering, technical infrastructure, and an implementation plan. FCC-ee can be built with today’s technology. Most of the FCC-ee infrastructure could be reused for FCC-hh. Combining concepts from past and present lepton colliders and adding a few novel elements, the FCC-ee design promises outstandingly high luminosity. This will make the FCC-ee a unique precision instrument to study the heaviest known particles (Z, W and H bosons and the top quark), offering great direct and indirect sensitivity to new physics.