Semiconductor detector readout chips with pulse processing electronics have made possible spectroscopic X-ray imaging, bringing an improvement in the overall image quality and, in the case of medical ...imaging, a reduction in the X-ray dose delivered to the patient. In this contribution we review the state of the art in semiconductor-detector readout ASICs for spectroscopic X-ray imaging with emphasis on hybrid pixel detector technology. We discuss how some of the key challenges of the technology (such as dealing with high fluxes, maintaining spectral fidelity, power consumption density) are addressed by the various ASICs. In order to understand the fundamental limits of the technology, the physics of the interaction of radiation with the semiconductor detector and the process of signal induction in the input electrodes of the readout circuit are described. Simulations of the process of signal induction are presented that reveal the importance of making use of the small pixel effect to minimize the impact of the slow motion of holes and hole trapping in the induced signal in high-Z sensor materials. This can contribute to preserve fidelity in the measured spectrum with relatively short values of the shaper peaking time. Simulations also show, on the other hand, the distortion in the energy spectrum due to charge sharing and fluorescence photons when the pixel pitch is decreased. However, using recent measurements from the Medipix3 ASIC, we demonstrate that the spectroscopic information contained in the incoming photon beam can be recovered by the implementation in hardware of an algorithm whereby the signal from a single photon is reconstructed and allocated to the pixel with the largest deposition.
Abstract
Timepix4 is a 24.7 × 30.0 mm
2
hybrid pixel detector readout ASIC which has been designed to permit detector tiling on 4 sides. It consists of 448 × 512 pixels which can be bump bonded to a ...sensor with square pixels at a pitch of 55 µm. Like its predecessor, Timepix3, it can operate in data driven mode sending out information (Time of Arrival, ToA and Time over Threshold, ToT) only when a pixel has a hit above a pre-defined and programmable threshold. In this mode hits can be tagged to a time bin of <200 ps and Timepix4 can record hits correctly at incoming rates of ∼3.6 MHz/mm
2
/s. In photon counting (or frame-based) mode it can count incoming hits at rates of up to 5 GHz/mm
2
/s. In both modes data is output via between 2 and 16 serializers each running at a programmable data bandwidth of between 40 Mbps and 10 Gbps. The specifications, architecture and circuit implementation are described along with first electrical measurements and measurements with radioactive sources. In photon counting mode X-ray images have been taken at a threshold of 650 e
−
(with <10 masked pixels). In data driven mode images were taken of ToA/ToT data using a
90
Sr source at a threshold of 800 e
−
(with ∼120 masked pixels).
The Medipix3 chips have been designed to permit spectroscopic imaging in highly segmented hybrid pixel detectors. Spectral degradation due to charge sharing in the sensor has been addressed by means ...of an architecture in which adjacent pixels communicate in the analog and digital domains on an event-by-event basis to reconstruct the deposited charge in a neighbourhood prior to the assignation of the hit to a single pixel. The Medipix3RX chip architecture is presented. The first results for the characterization of the chip with 300 mu m thick Si sensors are given. similar to 72e super(-) r.m.s. noise and similar to 40e super(-) r.m.s. of threshold dispersion after chip equalization have been measured in Single Pixel Mode of operation. The homogeneity of the image in Charge Summing mode is comparable to the Single Pixel Mode image. This demonstrates both modes are suitable for X-ray imaging applications.
Industrial penicillin production with the filamentous fungus Penicillium chrysogenum is based on an unprecedented effort in microbial strain improvement. To gain more insight into penicillin ...synthesis, we sequenced the 32.19 Mb genome of P. chrysogenum Wisconsin54-1255 and identified numerous genes responsible for key steps in penicillin production. DNA microarrays were used to compare the transcriptomes of the sequenced strain and a penicillinG high-producing strain, grown in the presence and absence of the side-chain precursor phenylacetic acid. Transcription of genes involved in biosynthesis of valine, cysteine and alpha-aminoadipic acid-precursors for penicillin biosynthesis-as well as of genes encoding microbody proteins, was increased in the high-producing strain. Some gene products were shown to be directly controlling beta-lactam output. Many key cellular transport processes involving penicillins and intermediates remain to be characterized at the molecular level. Genes predicted to encode transporters were strongly overrepresented among the genes transcriptionally upregulated under conditions that stimulate penicillinG production, illustrating potential for future genomics-driven metabolic engineering.
Celotno besedilo
Dostopno za:
DOBA, IJS, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Growing energies of particles at modern or planned particle accelerator experiments as well as cosmic ray experiments require particle identification at gamma-factors (γ) of up to ∼105. At present ...there are no detectors capable of identifying charged particles with reliable efficiency in this range of γ. New developments in high granular pixel detectors allow one to perform simultaneous measurements of the energies and the emission angles of generated transition radiation (TR) X-rays and use the maximum available information to identify particles. First results of studies of TR energy-angular distributions using gallium arsenide (GaAs) sensors bonded to Timepix3 chips are presented. The results are compared with those obtained using a silicon (Si) sensor of the same thickness of 500 μm. The analysis techniques used for these experiments are discussed.
X-ray transition radiation detectors (TRDs) are used for particle identification in both high energy physics and astroparticle physics. In most of the detectors, emission of the X-ray transition ...radiation (TR) starts at Lorentz factors above γ∼500 and reaches saturation at γ∼2÷3⋅103. However, many experiments require particle identification up to γ∼105, which is very difficult to achieve with conventional detectors. Semiconductor pixel detectors offer a unique opportunity for precise simultaneous measurements of spectral and angular parameters of TR photons. Test beam studies of the energy and the angular distributions of TR photons emitted by electrons and muons of different momenta crossing several types of radiators were performed at the CERN SPS with a 480 μm thick silicon detector bonded to a Timepix3 chip. High resolution images of the energy−angle phase space of the TR produced by different radiators were obtained and compared with MC simulations. The characteristic interference patterns are in agreement with the theoretical models with an unprecedented level of details. The studies presented in this paper also show that simultaneous measurements of both the energy and the emission angles of the TR X-rays could be used to enhance the particle identification performances of TRDs.
X-ray imaging is a widely used imaging modality in the medical diagnostic field due to its availability, low cost, high spatial resolution, and fast image acquisition. X-ray photons in standard X-ray ...sources are polychromatic. Detectors that allow to extract the "color" information of the individual X-rays can lead to contrast enhancement, improved material identification or reduction of beam hardening artifacts at the system level, if we compare them with the widely spread energy integrating detectors. Today, in the field of computed tomography (CT), prototypes of clinical grade systems based on spectral photon counting detectors are currently available for clinical research from different companies. One of the key system components in that development is the X-ray photon detector. This article reviews the photon detection hardware, from the conversion of X-rays into electrical signals to the pulse processing electronics. A review of available photon counting application specific integrated circuits (ASICs) for spectroscopic X-ray imaging is presented with emphasis on the CT medical imaging application.
Effective infection control measures during norovirus outbreaks are urgently needed in places where vulnerable individuals gather. In the present study, the effect of a number of measures was ...investigated in daily practice. Forty-nine Dutch nursing homes were monitored prospectively for norovirus outbreaks during two winter seasons. A total of 37 norovirus outbreaks were registered. Control measures were most effective when implemented within 3 days after onset of disease of the first patient. Measures targeted at reduced transmission between persons, via aérosols, and via contaminated surfaces reduced illness in staff and in residents. Reducing illness in staff results in fewer costs for sick leave and substitution of staff and less disruption in thè care of residents. The effect of control measures on outbreak duration was limited. This is the first intervention study examining the effect of control measures. Further research is needed to extend and refine the conclusions.
X-ray Transition radiation detectors (TRDs) are used for particle identification in both high energy physics and astroparticle physics. Particle identification is often achieved based on a threshold ...effect of the X-ray transition radiation (TR). In most of the detectors, TR emission starts at γ factors above ∼500 and reaches saturation at γ∼2−3⋅103. However, many experiments require particle identification up to γ∼105, which is difficult to achieve with current detectors, based only on the measurement of the photon energy together with the particle ionization losses. Additional information on the Lorentz factor can be extracted from the angular distribution of TR photons. TRDs based on pixel detectors give a unique opportunity for precise measurements of spectral and angular distributions of TR at the same time. A 500 μm thick silicon sensor bump bonded to a Timepix3 chip was used in a test beam measurement at the CERN SPS. A beam telescope was employed to separate clusters produced by the primary beam particles from the potential TR clusters. Spectral and angular distributions of TR were studied with high precision for the first time using beams of pions, electrons and muons at different momenta. In this paper, the measurement and analysis techniques are described, and first results are presented.