This paper discusses the cloud/clear discrimination algorithm (CLAUDIA) and the cloud microphysical properties algorithm (CAPCOM), which are used by the Second-generation GLobal Imager (SGLI) aboard ...the GCOM-C satellite, launched in December 2017. Also described are the preliminary results of cloud products’ validation. CLAUDIA was validated by comparing cloud fractions derived from satellite data against data from whole-sky images captured by ground-based fisheye cameras. User’s accuracy and producer’s accuracy were mostly high at around 90%, and the resulting overall accuracy was also high, ranging from 83 to 100% (average of all sites was 90.5%). CLAUDIA has proven to be sufficiently accurate to apply a cloud mask to measurements and meets the requirements for releasing data for SGLI cloud flag products (the minimum for a successful GCOM-C mission). CAPCOM was evaluated by comparing cloud properties obtained by SGLI products against data from MODIS collection 6 products (MOD06). This was done for both ocean and land in the low to middle latitudes (60° N–60° S) from August 22, 2018 to September 14, 2018. The comparison showed good correlation coefficients for cloud optical thickness, effective particle radius, and cloud-top temperature for water clouds: 0.88 (0.83), 0.92 (0.88), and 0.94 (0.92) for ocean (land), respectively. CAPCOM data for ice cloud optical thickness correlated well with data from MODIS products: 0.86 (ocean) and 0.82 (land).
Palsar Calibration and Validation SHIMADA, Masanobu; ISOGUCHI, Osamu; TADONO, Takeo ...
The Journal of Space Technology and Science,
2007, Letnik:
23, Številka:
1
Journal Article
Odprti dostop
This paper summarizes the geometric and radiometric calibration results of the PALSAR achieved during the ALOS initial calibration phase, which covers five months between May 16 2006 and October 23, ...2006, and the half-year of the operational phase. All the PALSAR modes, FBS (fine beam single), FBD (Fine beam dual), SCANSAR, DSN (band limited SAR), and POL (Full polarimetry) were calibrated and validated using in-total 500 calibration points collected world widely and distributed target data from the Amazon. Through the characterization of the PALSAR, antenna pattern determination, and polarimetric calibration, we performed the adjustments of the PALSAR radiometric and geometric model installed on the SAR processor (SIGMA-SAR). Using the reference points, we finally confirmed that the geometric accuracy of the FBS, FBD, DSN, and POL modes is 9.3m, that of SCANSAR is 70m, and radiometric accuracy is 0.64 dB. Polarimetric calibration was successful that amplitude balance of VV/HH is 0.025dB and the phase balance is 0.32 degrees.
The thermal infrared (TIR) band of Thermal and Near-Infrared Sensor for carbon Observations Fourier Transform Spectrometer (TANSO-FTS) on the Greenhouse gases Observing SATellite (GOSAT) measures a ...wide range of scene temperatures using a single detector band with broad spectral coverage. This work describes the vicarious radiometric calibration over a large footprint (10.5 km) and high temperature surface using well-calibrated ground-based and airborne FTS sensors. The vicarious calibration campaign of GOSAT was conducted at Railroad Valley, NV in June 2011. During the campaign, the Scanning High-resolution Interferometer Sounder (S-HIS) mounted on the high-altitude NASA ER-2 aircraft observed upwelling radiation and the ground-based Surface-Atmospheric Emitted Radiance Interferometer (S-AERI) observed infrared thermal emission from the atmosphere and the surface at the same location and time as the GOSAT TANSO-FTS. We validated TANSO-FTS TIR radiance with S-HIS radiance using double difference method, which reduces the effect of differences in the observation geometry. In this paper, we estimated the TANSO-FTS Instantaneous Field of View average temperature and emissivity by the coincident S-AERI and S-HIS observed radiance. The double difference between TANSO-FTS and S-HIS result in a difference of 0.5 K at atmospheric window channels (800 ~ 900 cm -1 ) and CO 2 warm brightness temperature channels (700 ~ 750 cm -1 ), 0.1 K at ozone channels (980 ~ 1080 cm -1 ), and more than 2 K at CO 2 cool brightness temperature channels (650 ~ 700 cm -1 ). The main reason of remaining errors is attributed to a calibration error in the TANSO-FTS Level 1B product version under evaluation.
PALSAR Radiometric and Geometric Calibration SHIMADA, Masanobu; WATANABE, Manabu; MORIYAMA, Toshifumi ...
Journal of The Remote Sensing Society of Japan,
2007/09/20, Letnik:
27, Številka:
4
Journal Article
Odprti dostop
This paper summarizes the geometric and radiometric calibration results of the PALSAR achieved during the ALOS initial calibration phase, which covers five months between May 16, 2006, and October ...23, 2006, and the half year of the operational phase. All the PALSAR modes, FBS (fine beam single), FBD (Fine beam dual), SCANSAR, DSN (band limited SAR), and PLR (Full polarimetry) were calibrated and validated using in-total 500 calibration points collected worldwide and distributed target data from the Amazon. Through the characterization of the PALSAR, antenna pattern determination, and polarimetric calibration, we performed the adjustments of the PALSAR radiometric and geometric model installed on the SAR processor (SIGMA-SAR). Using the reference points, we finally confirmed that the geometric accuracy of the FBS, FBD, DSN, and PLR modes is 9.3 m, that of SCANSAR is 70 m, and radiometric accuracy is 0.64 dB. Polarimetric calibration was successful that amplitude balance of VV/HH is 0.025 dB and the phase balance is 0.32 degrees.
PALSAR CALVAL summary and update 2007 Shimada, M.; Isoguchi, O.; Tadono, T. ...
2007 IEEE International Geoscience and Remote Sensing Symposium,
2007-July
Conference Proceeding
This paper summarizes the geometric and radiometric calibration results of the PALSAR achieved during the ALOS initial calibration phase, which covers five months between May 16 2006 and October 23, ...2006, and the half-year of the operational phase. All the PALSAR modes, FBS (fine beam single), FBD (Fine beam dual), SCANSAR, DSN (band limited SAR), and POL (Full polarimetry) were calibrated and validated using in-total 500 calibration points collected world widely and distributed target data from the Amazon. Through the characterization of the PALSAR, antenna pattern determination, and polarimetric calibration, we performed the adjustments of the PALSAR radiometric and geometric model installed on the SAR processor (SIGMA-SAR). Using the reference points, we finally confirmed that the geometric accuracy of the FBS, FBD, DSN, and POL modes is 9.3 m, that of SCANSAR is 70 m, and radiometric accuracy is 0.64 dB. Polarimetric calibration was successful that amplitude balance of VV/HH is 0.025 dB and the phase balance is 0.32 degrees.
We constructed gas a Cherenkov beam counter for a lead beam to obtain start signals of time of fight measurements for relativistic heavy ion experiments in WA98 at CERN-SPS. The intrinsic timing ...resolution of the gas Cherenkov counter was found to be ≤ 30 ps at a beam intensity up to 3 × 10
5 ions/s and the charge resolution (
ΔZ
Z
) was 2.0% for lead ions of 160 GeV/
c per nucleon. This counter has been successfully operated for more than
1
1
2
month of heavy ion run in 1995.