The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and ...optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.
The antihypertensive efficacy and tolerability of two betablockers: atenolol and bopindolol, was compared in a group of 30 elderly subjects aged 64.8 +/- 4.6 years. The daily dose of the two agents ...was relatively low. Atenolol 50-100 mg and bopindolol 0.5-1.0 mg sufficed to cause reduction of DBP to the target of less than or equal to 95 mm Hg, when applied as monotherapy. This was achieved in 75% of cases with bopindolol and in 93% of cases with atenolol. Atenolol, 50-100 mg/dd, lowered blood pressure from 173.7 +/- 13.2/103.7 +/- 3.0 (weekly) to 155.5 +/- 16.5/86.5 +/- 8.2 mm Hg (week 12) (P less than 0.005) while bopindolol, 0.5-1.0 mg, lowered blood pressure from 171.6 +/- 11.3/104.1 +/- 3.6 to 158.7 +/- 20.9/86.1 +/- 6.0 mm Hg (P less than 0.005). Heart rate was reduced from 80.5 (week 4) to 66.7 +/- 7.3 (week 12) by atenolol (P less than 0.0001), and from 83.7 +/- 11.8 (week 4) to 71.1 +/- 7.5 (week 12) by bopindolol (P less than 0.0001). Between treatment differences: comparisons yielded P values which were not sufficiently low to reject the null hypothesis of no difference between the two treatments. Well-being and short-term memory were not affected by either agent and tolerability of both drugs was good. These findings demonstrate that both bopindolol and atenolol are useful agents for control of hypertension in the elderly.
Serum from young normal BALB/c mice was found to contain IgM antibodies able to mediate complement-dependent lysis of certain syngeneic or allogeneic tumor target cells. The titer of such naturally ...occurring antitumor antibodies ( NATA ) was found to increase with aging. A longitudinal serological study comparing the cytotoxicity potential of NATA from normal and from urethan-treated BALB/c mice was performed. It was found that urethan-treated mice that did not develop primary lung-adenomas within the duration of the experiment had significantly lower NATA titers, against one out of 4 target cells assayed, than urethan-treated animals that developed lung adenomas. This difference was evident in two independent experiments. The results suggested that the lower NATA activity of the urethan-treated mice that did not develop tumors existed even before exposure to the carcinogenic insult. This raises the possibility that certain populations could be segregated according to their natural antibody profile into those individuals which will develop primary tumors within a certain period if exposed to a subthreshold amount of carcinogen, and those which will not.
Two new estimators for calibrating unknowns from dose-response curves, in a system of quality-controlled assays, are examined. In contrast with the conventional estimator which uses only the results ...of the one assay in which the response of the unknown dose is measured, the new estimators also utilize the results of all other assays through the replications of the control samples in the system. The first estimator is based on maximizing the likelihood of the given system (with respect to the different dose-response parameters, the levels of the control samples and the levels of the unknowns) when response errors are normally distributed. The second estimator is a regression-like estimator obtained by subtracting from the conventional estimator its estimated regression on the deviation of the calibrated control levels in the given assay from their average values in the system. Evaluations of the reductions in bias and variance attained by the new estimators show when substantial reductions in mean square error can be expected. The new estimators are illustrated with a system of 22 hFSH radioimmunoassays.
An extended Simes' test Hochberg, Yosef; Liberman, Uri
Statistics & probability letters,
09/1994, Letnik:
21, Številka:
2
Journal Article
Recenzirano
Simes' (1986) procedure for testing an intersection null hypothesis in terms of the individual p-values corresponding to the component hypotheses is extended to allow the allotment of different ...weights to the different component hypotheses. Preliminary necessary results on distributions of statistics based on the ordered values of independent non-identically distributed uniform random variables are obtained and used to prove (by induction) that the extended procedure controls the type-I error probability exactly at alpha.
Achilles tendon reflex time was measured in normal subjects (1,837 females and 7,937 males). Values of half relaxation time showed a clear dependency on both age and sex. The reflex becomes slower ...with advancing age and was consistently slower in females. The results redefine the normal range of the Achilles tendon reflex. Regression lines of relaxation time on age were fitted for each sex separately. Lines representing linear regression, log-linear regression or quadratic regression were inferior to those described by linear splines. The gradual increase of Achilles tendon relaxation time with age was not due to unrecognized hypothyroidism or peripheral neuropathy. It is suggested that one cause of the progressive increment is diminution of sympathetic tone with age, and changes in the muscles themselves may also contribute.
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino Background (CNB) detector, the first of its kind and the only one conceived that can look directly at the image of the ...Universe encoded in neutrino background produced in the first second after the Big Bang. The scope of the work for the next three years is to complete the conceptual design of this detector and to validate with direct measurements that the non-neutrino backgrounds are below the expected cosmological signal. In this paper we discuss in details the theoretical aspects of the experiment and its physics goals. In particular, we mainly address three issues. First we discuss the sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the perspectives of the experiment to detect the CNB via neutrino capture on tritium as a function of the neutrino mass scale and the energy resolution of the apparatus. Finally, we consider an extra sterile neutrino with mass in the eV range, coupled to the active states via oscillations, which has been advocated in view of neutrino oscillation anomalies. This extra state would contribute to the tritium decay spectrum, and its properties, mass and mixing angle, could be studied by analyzing the features in the beta decay electron spectrum.
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital ...magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential along the mid-plane of the filter. As a function of drift distance along the length of the filter, the filter zooms in with exponentially increasing precision on the transverse velocity component of the electron kinetic energy. This yields a linear dimension for the total filter length that is exceptionally compact compared to previous techniques for electromagnetic filtering. The parallel velocity component of the electron kinetic energy oscillates in an electrostatic harmonic trap as the electron drifts along the length of the filter. An analysis of the phase-space volume conservation validates the expected behavior of the filter from the adiabatic invariance of the orbital magnetic moment and energy conservation following Liouville's theorem for Hamiltonian systems.