Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given ...the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.
A
bstract
The very low radioactive background of the Borexino detector, its large size, and the well proved capability to detect both low energy electron neutrinos and antineutrinos make an ideal ...case for the study of short distance neutrino oscillations with artificial sources at Gran Sasso.
This paper describes the possible layouts of
51
Cr (
ν
e
) and
144
Ce-
144
Pr
source experiments in Borexino and shows the expected sensitivity to eV mass sterile neutrinos for three possible different phases of the experiment. Expected results on neutrino magnetic moment, electroweak mixing angle, and couplings to axial and vector currents are shown too.
U Thomas Jefferson National Acceleration Facility načinili smo prvo mjerenje elektrotvorbe hiperjezgre. Primijenili smo reakciju (e, e ′K+) na meti prirodnog C i opažali hiperjezgre 12ΛB. ...Raspravljamo spektar uzbude.
Abstract
Background: An ultrahigh-performance LC (UHPLC)–tandem MS (MS/MS) method for determination of paralytic shellfish poisoning toxins and tetrodotoxin (TTX) in bivalve molluscs was developed. ...To be used for regulatory testing, it needed to be validated through collaborative study. Objective: The aim was to conduct a collaborative study with 21 laboratories, using results to assess method performance. Methods: Study materials incorporated shellfish species mussels, oysters, cockles, scallops, and clams and were assessed to demonstrate stability and homogeneity. Mean concentrations determined by participants for blind duplicate samples were used to assess reproducibility, repeatability, and trueness. Results: Method performance characteristics were excellent following statistical assessment of participant data, with method trueness showing excellent method accuracy against expected values. No significant difference was found in the trueness results determined by different chromatographic column types. Acceptability of the between-laboratory reproducibility for individual analytes was evidenced by >99% of valid Horwitz ratio values being less than the 2.0 limit of acceptability. With excellent linearity and sensitivity fit-for-purpose over a range of mass spectrometer instruments, the UHPLC-MS/MS method compared well against other detection methods. It includes additional paralytic shellfish toxin (PST) analogues as well as TTX, which, to date, have not been incorporated into any other hydrophilic marine toxin official method of analysis. Conclusions: The results from this study demonstrate that the method is suitable for the analysis of PST analogues and TTX in shellfish tissues and is recommended as an official alternative method of analysis for regulatory control. Highlights: A new mass spectrometric method for PST and TTX has been validated successfully through collaborative study.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We present a measurement of the geo-neutrino signal obtained from 1353 days of data with the Borexino detector at Laboratori Nazionali del Gran Sasso in Italy. With a fiducial exposure of ...(3.69±0.16)×1031 proton × year after all selection cuts and background subtraction, we detected (14.3±4.4) geo-neutrino events assuming a fixed chondritic mass Th/U ratio of 3.9. This corresponds to a geo-neutrino signal Sgeo=(38.8±12.0) TNU with just a 6×10−6 probability for a null geo-neutrino measurement. With U and Th left as free parameters in the fit, the relative signals are STh=(10.6±12.7) TNU and SU=(26.5±19.5) TNU. Borexino data alone are compatible with a mantle geo-neutrino signal of (15.4±12.3) TNU, while a combined analysis with the KamLAND data allows to extract a mantle signal of (14.1±8.1) TNU. Our measurement of 31.2−6.1+7.0 reactor anti-neutrino events is in agreement with expectations in the presence of neutrino oscillations.
In this work, inclusive electron scattering from nuclear targets has been measured to extract the nuclear dependence of the inelastic cross section in Hall C at the Thomas Jefferson National ...Accelerator facility. Results are presented for 2H, 3He, 4He, 9B, 12C, 63Cu and 197Au at an incident electron beam energy of 5.77 GeV for a range of momentum transfer from Q2 = 2 to 7 (GeV/c)2. These data improve the precision of the existing measurements of the EMC effect in the nuclear targets at large x, and allow for more detailed examinations of the A dependence of the EMC effect.
Background: Retinoblastoma is the most common malignant tumour of the eye in childhood, with nearly all bilateral tumours and around 17% to 18% of unilateral tumours due to an oncogenic mutation in ...the RB1 gene in the germline. Genetic testing enables accurate risk assessment and optimal clinical management for the affected individual, siblings, and future offspring.
Material and Methods: We carried out the first UK‐wide audit of understanding of genetic testing in individuals with retinoblastoma. A total of 292 individuals aged 16 to 45 years were included.
Results: Patients with bilateral disease were significantly more likely to understand the implications of retinoblastoma for siblings and children. There was a significant association between not knowing the results of genetic testing or not understanding the implications and not having children, particularly in women. Surprisingly, this was also true for individuals treated for unilateral disease with a low risk of retinoblastoma for their offspring.
Conclusion: We are concerned that individuals may be making life choices based on insufficient information regarding risks of retinoblastoma and reproductive options. We suggest that improvement in transition care is needed to enable individuals to make informed reproductive decisions and to ensure optimal care for children born at risk of retinoblastoma.
Respondents who understood the genetic implications of retinoblastoma were significantly more likely to have children than those who did not understand the genetic implications of retinoblastoma
We describe the Monte Carlo (MC) simulation of the Borexino detector and the agreement of its output with data. The Borexino MC “ab initio” simulates the energy loss of particles in all detector ...components and generates the resulting scintillation photons and their propagation within the liquid scintillator volume. The simulation accounts for absorption, reemission, and scattering of the optical photons and tracks them until they either are absorbed or reach the photocathode of one of the photomultiplier tubes. Photon detection is followed by a comprehensive simulation of the readout electronics response. The MC is tuned using data collected with radioactive calibration sources deployed inside and around the scintillator volume. The simulation reproduces the energy response of the detector, its uniformity within the fiducial scintillator volume relevant to neutrino physics, and the time distribution of detected photons to better than 1% between 100 keV and several MeV. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino community, especially for current and future large-volume liquid scintillator experiments such as Kamland–Zen, SNO+, and Juno.