To develop a rigid real-time prospective motion-corrected multiparametric mapping technique and to test the performance of quantitative estimates.
Motion tracking and correction were performed by ...integrating single-shot spiral navigators into a multiparametric imaging technique, three-dimensional quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS). The spiral navigator was optimized, and quantitative measurements were validated using a standard system phantom. The effect of motion correction on whole-brain T1 and T2 mapping under different types of head motion during the scan was evaluated in 10 healthy volunteers. Finally, six patients with Parkinson's disease, which is known to be associated with a high prevalence of motion artifacts, were scanned to evaluate the effectiveness of our method in the real world.
The phantom study demonstrated that the proposed motion correction method did not introduce quantitative bias. Improved parametric map quality and repeatability were shown in volunteer experiments with both in-plane and through-plane motions, comparable to the no-motion ground truth. In real-life validation in patients, the approach showed improved parametric map quality compared to images obtained without motion correction.
Real-time prospective motion-corrected multiparametric relaxometry based on 3D-QALAS provided robust and repeatable whole-brain multiparametric mapping.
Assessment of treatment response in triple-negative breast cancer (TNBC) may guide individualized care for improved patient outcomes. Diffusion tensor imaging (DTI) measures tissue anisotropy and ...could be useful for characterizing changes in the tumors and adjacent fibroglandular tissue (FGT) of TNBC patients undergoing neoadjuvant systemic treatment (NAST).
To evaluate the potential of DTI parameters for prediction of treatment response in TNBC patients undergoing NAST.
Prospective.
Eighty-six women (average age: 51 ± 11 years) with biopsy-proven clinical stage I-III TNBC who underwent NAST followed by definitive surgery. 47% of patients (40/86) had pathologic complete response (pCR).
3.0 T/reduced field of view single-shot echo-planar DTI sequence.
Three MRI scans were acquired longitudinally (pre-treatment, after 2 cycles of NAST, and after 4 cycles of NAST). Eleven histogram features were extracted from DTI parameter maps of tumors, a peritumoral region (PTR), and FGT in the ipsilateral breast. DTI parameters included apparent diffusion coefficients and relative diffusion anisotropies. pCR status was determined at surgery.
Longitudinal changes of DTI features were tested for discrimination of pCR using Mann-Whitney U test and area under the receiver operating characteristic curve (AUC). A P value <0.05 was considered statistically significant.
47% of patients (40/86) had pCR. DTI parameters assessed after 2 and 4 cycles of NAST were significantly different between pCR and non-pCR patients when compared between tumors, PTRs, and FGTs. The median surface/average anisotropy of the PTR, measured after 2 and 4 cycles of NAST, increased in pCR patients and decreased in non-pCR patients (AUC: 0.78; 0.027 ± 0.043 vs. -0.017 ± 0.042 mm
/s).
Quantitative DTI features from breast tumors and the peritumoral tissue may be useful for predicting the response to NAST in TNBC.
1 TECHNICAL EFFICACY: Stage 4.
Purpose
Precise correlation between three‐dimensional (3D) imaging and histology can aid biomechanical modeling of the breast. We develop a framework to register ex vivo images to histology using a ...novel cryo‐fluorescence tomography (CFT) device.
Methods
A formalin‐fixed cadaveric breast specimen, including chest wall, was subjected to high‐resolution magnetic resonance (MR) imaging. The specimen was then frozen and embedded in an optimal cutting temperature (OCT) compound. The OCT block was placed in a CFT device with an overhead camera and 50 μm thick slices were successively shaved off the block. After each shaving, the block‐face was photographed. At select locations including connective/adipose tissue, muscle, skin, and fibroglandular tissue, 20 μm sections were transferred onto cryogenic tape for manual hematoxylin and eosin staining, histological assessment, and image capture. A 3D white‐light image was automatically reconstructed from the photographs by aligning fiducial markers embedded in the OCT block. The 3D MR image, 3D white‐light image, and photomicrographs were rigidly registered. Target registration errors (TREs) were computed based on 10 pairs of points marked at fibroglandular intersections. The overall MR‐histology registration was used to compare the MR intensities at tissue extraction sites with a one‐way analysis of variance.
Results
The MR image to CFT‐captured white‐light image registration achieved a mean TRE of 0.73 ± 0.25 mm (less than the 1 mm MR slice resolution). The block‐face white‐light image and block‐face photomicrograph registration showed visually indistinguishable alignment of anatomical structures and tissue boundaries. The MR intensities at the four tissue sites identified from histology differed significantly (p < 0.01). Each tissue pair, except the skin‐connective/adipose tissue pair, also had significantly different MR intensities (p < 0.01).
Conclusions
Fine sectioning in a highly controlled imaging/sectioning environment enables accurate registration between the MR image and histology. Statistically significant differences in MR signal intensities between histological tissues are indicators for the specificity of correlation between MRI and histology.
A flexible fast spin echo triple‐echo Dixon technique Son, Jong Bum; Hwang, Ken‐Pin; Madewell, John E. ...
Magnetic resonance in medicine,
March 2017, 2017-03-00, 20170301, Letnik:
77, Številka:
3
Journal Article
Purpose
MR‐only treatment planning requires images of high geometric fidelity, particularly for large fields of view (FOV). However, the availability of large FOV distortion phantoms with analysis ...software is currently limited. This work sought to optimize a modular distortion phantom to accommodate multiple bore configurations and implement distortion characterization in a widely implementable solution.
Method and Materials
To determine candidate materials, 1.0 T MR and CT images were acquired of twelve urethane foam samples of various densities and strengths. Samples were precision‐machined to accommodate 6 mm diameter paintballs used as landmarks. Final material candidates were selected by balancing strength, machinability, weight, and cost. Bore sizes and minimum aperture width resulting from couch position were tabulated from the literature (14 systems, 5 vendors). Bore geometry and couch position were simulated using MATLAB to generate machine‐specific models to optimize the phantom build. Previously developed software for distortion characterization was modified for several magnet geometries (1.0 T, 1.5 T, 3.0 T), compared against previously published 1.0 T results, and integrated into the 3D Slicer application platform.
Results
All foam samples provided sufficient MR image contrast with paintball landmarks. Urethane foam (compressive strength ∼1000 psi, density ~20 lb/ft3) was selected for its accurate machinability and weight characteristics. For smaller bores, a phantom version with the following parameters was used: 15 foam plates, 55 × 55 × 37.5 cm3 (L×W×H), 5,082 landmarks, and weight ~30 kg. To accommodate > 70 cm wide bores, an extended build used 20 plates spanning 55 × 55 × 50 cm3 with 7,497 landmarks and weight ~44 kg. Distortion characterization software was implemented as an external module into 3D Slicer's plugin framework and results agreed with the literature.
Conclusion
The design and implementation of a modular, extendable distortion phantom was optimized for several bore configurations. The phantom and analysis software will be available for multi‐institutional collaborations and cross‐validation trials to support MR‐only planning.
Purpose
To determine if tumor necrosis by pretreatment breast MRI and its quantitative imaging characteristics are associated with response to NAST in TNBC.
Methods
This retrospective study included ...85 TNBC patients (mean age 51.8 ± 13 years) with MRI before NAST and definitive surgery during 2010–2018. Each MRI included T2-weighted, diffusion-weighted (DWI), and dynamic contrast-enhanced (DCE) imaging. For each index carcinoma, total tumor volume including necrosis (TTV), excluding necrosis (TV), and the necrosis-only volume (NV) were segmented on early-phase DCE subtractions and DWI images. NV and %NV were calculated. Percent enhancement on early and late phases of DCE and apparent diffusion coefficient were extracted from TTV, TV, and NV. Association between necrosis with pathological complete response (pCR) was assessed using odds ratio (OR). Multivariable analysis was used to evaluate the prognostic value of necrosis with T stage and nodal status at staging. Mann–Whitney
U
tests and area under the curve (AUC) were used to assess performance of imaging metrics for discriminating pCR vs non-pCR.
Results
Of 39 patients (46%) with necrosis, 17 had pCR and 22 did not. Necrosis was not associated with pCR (OR, 0.995; 95% confidence interval CI 0.4–2.3) and was not an independent prognostic factor when combined with T stage and nodal status at staging (
P
= 0.46). None of the imaging metrics differed significantly between pCR and non-pCR in patients with necrosis (AUC < 0.6 and
P
> 0.40).
Conclusion
No significant association was found between necrosis by pretreatment MRI or the quantitative imaging characteristics of tumor necrosis and response to NAST in TNBC.
Magnetic resonance imaging (MRI) offers outstanding soft tissue contrast that may reduce uncertainties in target and organ-at-risk delineation and enable online adaptive image-guided treatment. ...Spatial distortions resulting from non-linearities in the gradient fields and non-uniformity in the main magnetic field must be accounted for across the imaging field-of-view to prevent systematic errors during treatment delivery. This work presents a modular phantom and software application to characterize geometric distortion (GD) within the large field-of-view MRI images required for radiation therapy simulation. The modular phantom is assembled from a series of rectangular foam blocks containing high-contrast fiducial markers in a known configuration. The modular phantom design facilitates transportation of the phantom between different MR scanners and MR-guided linear accelerators and allows the phantom to be adapted to fit different sized bores or coils. The phantom was evaluated using a 1.5 T MR-guided linear accelerator (MR-Linac) and 1.5 T and 3.0 T diagnostic scanners. Performance was assessed by varying acquisition parameters to induce image distortions in a known manner. Imaging was performed using T1 and T2 weighted pulse sequences with 2D and 3D distortion correction algorithms and the receiver bandwidth (BW) varied as 250-815 Hz pixel−1. Phantom set-up reproducibility was evaluated across independent set-ups. The software was validated by comparison with a non-modular phantom. Average geometric distortion was 0.94 ± 0.58 mm for the MR-Linac, 0.90 ± 0.53 mm for the 1.5 T scanner, and 1.15 ± 0.62 mm for the 3.0 T scanner, for a 400 mm diameter volume-of-interest. GD increased, as expected, with decreasing BW, and with the 2D versus 3D correction algorithm. Differences in GD attributed to phantom set-up were 0.13 mm or less. Differences in GD for the two software applications were less than 0.07 mm. A novel modular phantom was developed to evaluate distortions in MR images for radiation therapy applications.
Imaging metabolic dysfunction, a hallmark of solid tumors, usually requires radioactive tracers. Chemical exchange saturation transfer (CEST) imaging can potentially detect and visualize glucose ...uptake and metabolism, without the need for radioisotopes. Here, we tested the feasibility of using glucose CEST (glucoCEST) to image unlabeled glucose uptake in head and neck cancer by using a clinical 3T magnetic resonance imaging (MRI) scanner. The average CEST contrast between tumors and normal tissue in 17 patients was 7.58% (P = 0.006) in the 3-4 ppm offset frequency range and 5.06% (P = 0.02) in 1-5 ppm range. In a subgroup of eight patients, glucoCEST signal enhancement was higher in tumors than in normal muscle (4.98% vs. 1.28%, P < 0.021). We conclude that glucoCEST images of head and neck cancer can be obtained with a clinical 3T MRI scanner.
Acquisition parameter selection is currently performed empirically for many quantitative MRI (qMRI) acquisitions. Tuning parameters for different scan times, tissues, and resolutions requires some ...amount of trial and error. There is an opportunity to quantitatively optimize these acquisition parameters in order to minimize variability of quantitative maps and post-processing techniques such as synthetic image generation. The objective of this work is to introduce and evaluate a quantitative method for selecting parameters that minimize image variability. An information theory framework was developed for this purpose and applied to a 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) signal model for qMRI. In this framework, mutual information is used to measure the information gained by a measurement as a function of acquisition parameters, quantifying the information content of potential acquisitions and allowing informed parameter selection. The information theory framework was tested on artificial data generated from a representative mathematical phantom, measurements acquired on a qMRI multiparametric imaging standard phantom, and in vivo measurements in a human brain. The phantom measurements showed that higher mutual information calculated by the model correlated with smaller coefficient of variation in the reconstructed parametric maps, and in vivo measurements demonstrated that information-based calibration of acquisition parameters resulted in a decrease in parametric map variability consistent with model predictions.