Purpose: The present study aims to evaluate the effectiveness and safety of the anti-reflux microcatheter during DEB-TACE with DC Bead LUMITM (radiopaque beads) for the treatment of hepatocellular ...carcinoma (HCC). Methods: We performed an observational longitudinal prospective monocentric study to analyze all patients with HCC who underwent to DEB-TACE with DC Bead LUMITM and anti-reflux microcatheter. Technical success, the presence of residual disease, and clinical success were evaluated. The performance of the anti-reflux microcatheter on the basis of the percentage of tumor covered and the non-target embolization (NTE) was also evaluated. Results: Twenty patients underwent DEB-TACE with DC Bead LUMITM and an anti-reflux microcatheter. Technical success was achieved in all cases. Residual disease in the target tumor was observed in 11/20 (55%) of cases and no residual disease was found in 9/20 (45%) of cases. The clinical response at 1-month follow-up was of PD 4/20 (20%), SD 7/20 (35%), and CR 9/20 (45%). No major complications were recorded, and 10% of cases had minor complications. The distribution of beads on post-procedural CBCT, classified according to the percentage of target nodule coverage, was ≥50% in 70% (14/20) of cases and between 30–50% in 30% of cases (6/20). NTE was never registered.
Splenic artery pseudoaneurysm (PSA) is a contained vascular wall lesion associated with a high mortality rate, generally related to pancreatitis, trauma, malignancy, iatrogenic injury, and segmental ...arterial mediolysis. Computed tomography angiography allows us to visualize the vascular anatomy, differentiate a PSA from an aneurysm, and provide adequate information for endovascular/surgical treatment. The present review reports on the main state-of-the-art splenic artery PSA diagnosis, differentiating between the pros and cons of the imaging methods and about the endovascular treatment.
Background: Several studies report an inhibitory effect of probiotics on Helicobacter pylori.
Aim: To test whether Lactobacillus reuteri ATCC 55730 reduces H. pylori intragastric load in vivo, ...decreases dyspeptic symptoms, and affects eradication rates after conventional treatment.
Materials and Methods: In a double‐blind placebo‐controlled study, 40 H. pylori‐positive subjects were given L. reuteri once a day for 4 weeks or placebo. All underwent upper endoscopy, 13C‐urea breath test, and H. pylori stool antigen determination at entry and 13C‐urea breath test and H. pylori stool antigen (used as both qualitative and semiquantitative markers) after 4 weeks of treatment. Sequential treatment was administered subsequently to all.
Results: In vivo, L. reuteri reduces H. pylori load as semiquantitatively assessed by both 13C‐urea breath test δ‐value and H. pylori stool antigen quantification after 4 weeks of treatment (p < .05). No change was shown in patients receiving placebo. L. reuteri administration was followed by a significant decrease in the Gastrointestinal Symptom Rating Scale as compared to pretreatment value (p < .05) that was not present in those receiving placebo (p = not significant). No difference in eradication rates was observed.
Conclusions: L. reuteri effectively suppresses H. pylori infection in humans and decreases the occurrence of dyspeptic symptoms. Nevertheless, it does not seem to affect antibiotic therapy outcome.
Objective
The aim of this study is to evaluate the feasibility, safety, and short-term effectiveness of a high-power (150 W) microwave ablation (MWA) device for tumor ablation in the lung, liver, and ...kidney.
Methods
Between December 2021 and June 2022, patients underwent high-power MWA for liver, lung, and kidney tumors. A retrospective observational study was conducted in accordance with the Declaration of Helsinki. The MWA system utilized a 150-W, 2.45-GHz microwave generator (Emprint™ HP Ablation System, Medtronic). The study assessed technical success, safety, and effectiveness, considering pre- and post-treatment diameter and volume, lesion location, biopsy and/or cone beam computed tomography (CBCT) usage, MWA ablation time, MWA power, and dose-area product (DAP).
Results
From December 2021 to June 2022, 16 patients were enrolled for high-power MWA. Treated lesions included hepatocellular carcinoma (10), liver metastasis from colon cancer (1), liver metastasis from pancreatic cancer (1), squamous cell lung carcinoma (2), renal cell carcinoma (1), and renal oncocytoma (1). Technical success rate was 100%. One grade 1 complication (6.25%) was reported according to CIRSE classification. Overall effectiveness was 92.8%. Pre- and post-treatment mean diameters for liver lesions were 19.9 mm and 37.5 mm, respectively; for kidney lesions, 34 mm and 35 mm; for lung lesions, 29.5 mm and 31.5 mm. Pre- and post-treatment mean volumes for liver lesions were 3.4 ml and 24 ml, respectively; for kidney lesions, 8.2 ml and 20.5 ml; for lung lesions, 10.2 ml and 32.7 ml. The mean ablation time was 48 minutes for liver, 42.5 minutes for lung, and 42.5 minutes for renal ablation. The mean DAP for all procedures was 40.83 Gcm2.
Conclusion
This preliminary study demonstrates the feasibility, safety, and effectiveness of the new 150 W MWA device. Additionally, it shows reduced ablation times for large lesions.
This review focuses on the use of “new” generation of non-adhesive liquid embolic agents (NALEA). In literature, non-adhesive liquid embolic agents have mainly been used in the cerebral district; ...however, multiple papers describing the use of NALEA in the extracranial district have been published recently and the aim of this review is to explore and analyze this field of application. There are a few NALEA liquids such as Onyx, Squid, and Phil currently available in the market, and they are used in the following applications: mainly arteriovenous malformations, endoleaks, visceral aneurysm or pseudoaneurysm, presurgical and hypervascular lesions embolization, and a niche of percutaneous approaches. These types of embolizing fluids can be used alone or in combination with other embolizing agents (such as coils or particles) so as to enhance its embolizing effect or improve its possible defects. The primary purpose of this paper is to evaluate the use of NALEAs, predominantly used alone, in elective embolization procedures. We did not attempt a meta-analysis due to the data heterogeneity, high number of case reports, and the lack of a consistent follow-up time period.
Purpose
The aim of this study was to describe the safety and efficacy profiles of TACE using DC Beads LUMI.
Materials and methods
We retrospectively analyzed 90 patients with HCC who underwent TACE ...with DC Bead LUMI™ between November 2018 and November 2020 at Fondazione IRCCS Cà Granda Policlinico Hospital in Milan, Italy. Patient- and tumour-related factors were registered, including the number of treated lesions, dose of DC Beads LUMI™, dose of Epirubicin, DC Beads LUMI™ target tumour coverage (LC) according to the percentage of target nodule involvement (LC1-0%–25%, LC2-25%–50%, LC3-50%–75%, LC4 75%–100%). Treatment efficacy was obtained through reviewing the follow-up imaging for evidence of response in target lesion(s), according to modified response criteria in solid tumours (mRECIST) criteria with the following outcomes: complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD). Safety assessment was based on the quantitative and qualitative recording of the adverse events, classified according to CIRSE classification.
Results
Seventy-two patients were enrolled, and 95 procedures were carried out. We observed a target tumour response rate at 1 month with CR in 68%, PR in 10.3% 11.8%, SD in 13%, PD in 7.2%, and an overall tumour(s) (whole liver) response at 1 month with CR in 58.9%, PR in 12.6%, SD in 10.5% and PD in 18%. We found a significant association (p < 0.01) between tumour response CR or CR + PR and the number of the target lesion(s). CIRSE classification grade I and grade II complications were recorded, respectively, in 11 (11.6%) and 6 (6.3%) procedures. No grade III-IV-V complications occurred.
Conclusion
TACE using DC Beads LUMI is a safe and effective treatment option for patients with HCC.
Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator ...variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of “Prediction Ablation Volume Software” may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) “Prediction Ablation Volume Software.” This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation.
Dual-Energy computed tomography (DECT) with its various advanced techniques, including Virtual Non-Contrast (VNC), effective atomic number (Z-eff) calculation, Z-maps, Iodine Density Index (IDI), and ...so on, holds great promise in the diagnosis and management of urogenital tumours. In this narrative review, we analyze the current status of knowledge of this technology to provide better lesion characterization, improve the staging accuracy, and give more precise treatment response assessments in relation to urological tumours.
It is imperative to ensure the safety of health-care workers in the angiographic room during the outbreak of the coronavirus disease 2019 (COVID-19). The selection criteria for interventional ...radiology (IR) procedures, the preparation of the staff and angiographic suite, ventilation systems, and intra- and post-procedural workflow optimization methods are detailed. The specific measures needed to protect occupational safety and health may result in higher costs, longer procedural times, and greater technical problems. However, these precautions may help to minimize the spread of COVID-19 among IR practitioners.