As a result of the LHC injectors upgrade after the Long Shutdown (2019-2020), the expected Pb-Pb luminosity and collision rate during the so called Runs 3 and 4 will considerably exceed the design ...parameters for several of the key ALICE detectors systems including the forward trigger detectors. Fast Interaction Trigger (FIT) will be the primary forward trigger, luminosity, and collision time measurement detector. It will also determine multiplicity, centrality, and reaction plane of heavy ion collisions. FIT is expected to match and even exceed the functionality and performance currently secured by three ALICE sub-detectors: the time zero detector (T0), the VZERO system (V0), and the Forward Multiplicity Detector (FMD). FIT will consist of two arrays of Cherenkov radiators with MCP-PMT sensors and of a single, large-size scintillator ring. Because of the presence of the muon spectrometer, the placement of the FIT arrays will be asymmetric: ∼800 mm from the interaction point (IP) on the absorber side and ∼3200 mm from IP on the opposite side. The ongoing beam tests and Monte Carlo studies verify the physics performance and refine the geometry of the FIT arrays. The presentation gives a short description of FIT, triggers and readout requirement for the ALICE Upgrade, a summary of the performance, and the outcome of the simulations and beam tests.
Abstract
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/ FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a ...study of their gain stability over time and saturation level in terms of the average anode current are presented. This information allows one to determine the lower limit of the MCP resistance for stable Planacon operation. The spread of the electron multiplication characteristics for the entire production batch is also presented, indicating the remarkably low voltage requirements of these MCP-PMTs. Detection efficiency and noise characteristics, such as dark count rate and afterpulsing level, are also reviewed.
We have measured and compared the characteristics of ALD-coated Planacon® MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the latter show excellent performance, the ...ALD-coated sensors have surprisingly low current saturation levels (∼ two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected). We suspect that these problems might be caused by the unexpected side-effects of the ALD process. To make a definite conclusion, more samples need to be tested, preferably from different production runs. If our observation were confirmed, it would mean a serious technological setback for ALD-coated MCP-PMTs.
Beam test of FARICH prototype with digital photon counter Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
In June 2012 we tested a Focusing Aerogel RICH detector prototype based on Digital Photon Counters (DPC) by Philips at the CERN PS T10 beam line with a particle momentum up to 6GeV/c. The prototype ...comprises a 20×20cm2 photon detector with 48×48 DPC pixels. In order to reduce the dark count rate, the photon detector was cooled to −40°C in addition to disabling individual DPC's microcells. A four layer focusing aerogel radiator with 200mm focal distance was studied. We obtained a Cherenkov angle resolution of 3.61±0.04mrad. The mean number of photoelectrons in a ring is 12. Directly measured π/K separation at 6GeV/c momentum is 3.5σ, μ/π separation is 5.3σ at 1GeV/c. A comparison with a Monte Carlo simulation is presented as well.
•Focusing Aerogel RICH prototype with Digital Photon Counters by Philips was built.•The prototype was tested at the CERN PS T10 beam line.•We observed Cherenkov rings with 12 photoelectrons in average.•Timing resolution of DPCs is 48ps for single photons.•Cherenkov angle resolution is 3.64±0.04mrad per ring.
Tests of FARICH prototype with precise photon position detection Barnyakov, A.Yu; Barnyakov, M.Yu; Basok, I.Yu ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2014, Letnik:
766
Journal Article
Recenzirano
In June 2012 a FARICH prototype from Philips Digital Photon Counting (PDPC) based on a photon camera with dimensions of 200200 mm has been tested at CERN. Remarkable particle separation has been ...achieved with a 4-layer aerogel sample: the pi /K separation at a 6 GeV/c momentum is 3.5 sigma , the mu / pi mu / pi separation is 5.3 sigma at 1 GeV/c. The analysis of the data has shown that the main contribution to the accuracy of the ring radius measurement comes from aerogel. The development of focusing aerogels is proceeding in two main directions: tuning of production technology of multilayer blocks and development of a new production method with continuous density (refractive index) gradient along the block depth. The beam test was carried out in December 2012-January 2013 at the electron beam test facility at the VEPP-4 M e super(+)e super(-) collider. The goal of this test was to measure different single layer and focusing aerogel samples, both multilayer and gradient. Aerogel samples were tested with a PDPC FARICH prototype. A part of DPC SPADs in each pixel was disabled to form an active area of 11 mm super(2). The collected data proved that gradient aerogel samples focus Cherenkov light.
We present a new measurement of $J/\psi$ production in Pb-Pb collisions at 158 GeV/nucleon, from the data sample collected in year 2000 by the NA50 Collaboration, under improved experimental ...conditions with respect to previous years. With the target system placed in vacuum, the setup was better adapted to study, in particular, the most peripheral nuclear collisions with unprecedented accuracy. The analysis of this data sample shows that the ($J/\psi$)/Drell-Yan cross-sections ratio measured in the most peripheral Pb-Pb interactions is in good agreement with the nuclear absorption pattern extrapolated from the studies of proton-nucleus collisions. Furthermore, this new measurement confirms our previous observation that the ($J/\psi$)/Drell-Yan cross-sections ratio departs from the normal nuclear absorption pattern for semi-central Pb-Pb collisions and that this ratio persistently decreases up to the most central collisions.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We present the behavior of the cost-effective Planacon MCP-PMTs with 25μm pore diameter in the presence of axial magnetic fields up to 0.5 T. Having a batch of 62 devices of the same type, two ...MCP-PMTs were selected and their gain variation measured in different magnetic fields. These two otherwise identical devices satisfied the selection criteria by requiring the lowest (1.15 kV) and one of the highest (1.4 kV) bias voltage values to achieve a given gain. Both MCP-PMTs have a nearly identical tolerance of the strong magnetic field despite the significant difference in the bias voltage. This clarifies the mechanism of the B-field influence on the MCP-PMT gain, emphasizing the importance of the intrinsic parameters of the MCP emissive coating rather than external parameters, such as the total bias voltage. By evaluating the dependence of both gain and timing parameters on the magnetic field strength, we confirm the operability of such MCP-PMTs in strong magnetic fields in spite of the relatively large pore diameter and low bias voltage required for a given gain.
Main properties of the multi-anode microchannel plate photomultiplier to be used in a Cherenkov detector are discussed. The laboratory test results obtained using irradiation of the MCP-PMT ...photocathode by picosecond optical laser pulses with different intensities (from single photon regime to the PMT saturation conditions) are presented.
Prototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We ...present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.