To compare the safety and efficacy of microshunt implantation augmented with Mitomycin C in patients with pseudoexfoliation glaucoma (PEXG) and primary open-angle glaucoma (POAG).
In this ...retrospective, single centre, interventional study, 46 eyes of 41 patients with PEXG (20 eyes) and POAG (26 eyes) underwent microshunt implantation. Definition of failure was an intraocular pressure (IOP) lower than 5 or higher than 17mmHg on two consecutive visits, an IOP reduction lower than 20% on two consecutive visits, the need of surgical revisions or reoperations or loss of light perception. Outcome was rated as complete success if achieved without medication, otherwise as qualified success. Furthermore, postoperative complications and interventions were compared between the two groups.
Patient demographics were similar, except for older age in the PEXG group (70.9±8.6 versus 77.6±8; p = 0.02). Mean IOP dropped from 21.5±5.8mmHg (PEXG) and 18.2±4.5mmHg (POAG) at baseline to 12.8±3.0mmHg (p<0.0001) and 12.9±4.2mmHg (p<0.0001), respectively, at one year. Mean number of medications were reduced from 2.8±1.3 to 0.3±0.8 for PEXG patients (p<0.0001) and from 2.7±1.3 to 0.3±0.8 for POAG patients (p<0.0001). At one year of follow-up 75.0% of PEXG patients achieved complete success and 80.0% qualified success. In the POAG group rates were 73.1% and 76.9%, respectively. Postoperative complications were comparable between both groups, except for higher rates of hypotony (p = 0.04) and choroidal detachment (p = 0.03) in the PEXG group.
Microshunt implantation demonstrated similar efficacy results in PEXG and POAG eyes at a follow-up of 12 months. Higher rates of transient hypotony and choroidal detachment were observed in PEXG eyes.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
Little is known about the connection between preoperative keratometry and postoperative results of myopic small-incision lenticule extraction (SMILE). To determine the influence of extreme ...(flat and steep) corneal keratometry on the safety and efficacy of SMILE, the databases of the Department of Ophthalmology, Ludwig-Maximilians-University Munich, Germany, and SMILE Eyes Linz, Austria, were screened for patients with steep and flat keratometry who had undergone SMILE. In this cross-sectional matched comparative cohort study, eyes with markedly flat (< 42.0 diopters; D) or steep (≥ 47.0D) preoperative corneal keratometry were matched to a cohort of eyes with regular keratometry (42.0–46.9D) by preoperative manifest refractive spherical equivalent and cylinder, age, corrected distance visual acuity and surgical SMILE parameters. The standardized graphs and terms for refractive surgery results were applied to compare the three groups. Changes in higher order aberrations (HOAs) were evaluated on Scheimpflug imaging. In total, 63 eyes (21 each) of 54 patients with a mean refractive spherical equivalent of − 5.21 ± 1.59 D were followed up for a mean of 9.2 ± 6.1 (minimum ≥ 3) months. Mean baseline keratometry was 41.3 ± 0.7D (flat), 45.5 ± 1.0D (regular) and 47.7 ± 0.6D (steep) (p < 0.0001). Compared to the regular group, the flat and the steep cornea group resulted in a non-inferior percentage of eyes within ± 0.50 D of target refraction (p = 0.20), uncorrected distance visual acuity (p = 0.95) and corrected distance visual acuity (p = 0.20). Flat corneas however experienced a stronger induction of spherical aberration (SA) compared to the steep group (p = 0.0005). In conclusion, non-inferior outcomes of SMILE can also be expected in eyes with steep (≥ 47D) or flat (< 42D) preoperative keratometry, while SMILE however induces more SA in eyes with a flat keratometry.
EVA NEXUS-Phaco performance study Feldhaus, Lukas; Kassumeh, Stefan; Priglinger, Siegfried ...
International journal of ophthalmology,
08/2024, Letnik:
17, Številka:
8
Journal Article
Recenzirano
Odprti dostop
AIM: To investigate a novel phacoemulsification system “EVA NEXUS” (D.O.R.C., Dutch Opthalmic Research Center) in comparison to the existing system “EVA” in clinical use. And to compare both ...phacoemulsification systems in terms of efficiency, safety and postoperative inflammatory activity. METHODS: In this study standardized cataract surgery was performed on both eyes of the study participant, using the “EVA system” (control group, n=20) on one eye and the “EVA NEXUS system” (intervention group, n=20) on the other eye. Only patients with cataract LOCS Grading 1-3 and no accompanying eye diseases were included in this study. A total of 20 patients were included in this study, with each treatment arm including 20 eyes. During surgery a 0.1 mL aqueous humor sample was collected 1min after phacoemulsification to measure the total prostaglanin E2 concentrations using an enzyme-linked immunosorbent assay. The endothelial cell count, visual and refractive outcomes, and anterior chamber flare were evaluated preoperatively, and 1d, 1wk, and 3mo postoperatively. RESULTS: There were no statistically significant differences between both groups regarding intraoperative safety parameters including effective phacoemulsification time (P=0.904), balanced saline solution flow (P=0.701) and total surgery time (P=0.565). Postoperative prostaglandin E2 levels, anterior chamber flare as well as endothelial cell loss tended to be lower in the NEXUS-Group, however not being statistically significant (P=0.718; 0.164; 0.486). Both systems provided similar clinical outcomes, regarding best corrected visual acuity and refractive parameters, showing no statistically significant differences between both groups. CONCLUSION: Both systems show a high level of safety and efficency with similar results in terms of safety parameters including postoperative inflammatory activity and endothelial cell loss as well as visual and refractive outcomes. Although statistically not significant, the EVA NEXUS system tends to cause less postoperative inflammation with lower prostaglandin E2 levels and lower anterior chamber flare values.
Protein crosslinking photosensitized by rose Bengal (RB2−) has multiple medical applications and understanding the photosensitization mechanism can improve treatment effectiveness. To this end, we ...investigated the photochemical efficiencies of monomeric RB2− (RBM2−) and dimeric RB2− (RBD2−) and the optimal pH for anaerobic RB2− photosensitization in cornea. Absorption spectra and dynamic light scattering (DLS) measurements were used to estimate the fractions of RBM2− and RBD2−. RB2− self‐photosensitized bleaching was used to evaluate the photoactivity of RBM2− and RBD2−. The pH dependence of anaerobic RB2− photosensitization was evaluated in ex vivo rabbit corneas. The 549 nm/515 nm absorption ratio indicated that concentrations > 0.10 mm RB contained RBD2−. Results from DLS gave estimated mean diameters for RBM2− and RBD2− of 0.70 ± 0.02 nm and 1.75 ± 0.13 nm, respectively, and indicated that 1 mm RB2− contained equal fractions of RBM2− and RBD2−. Quantum yields for RB2− bleaching were not influenced by RBD2− in RB2− solutions although accounting for RB2− concentration effects on the reaction kinetics demonstrated that RBD2− is not a photosensitizer. Optimal anaerobic photosensitization occurred at pH 8.5 for solutions containing 200 mm Arg. These results suggest potential approaches to optimizing RBM2−‐photosensitized protein crosslinking in tissues.
Rose Bengal (RB2−)‐photosensitized crosslinking of protein in tissues has many applications in medicine. To improve the effectiveness of these treatments, we investigated the photochemical efficiencies of monomeric RB2− and dimeric RB2−. Dynamic light scattering (DLS) indicated that the treatment solution used for medical applications (1 mm RB2− in PBS) contains a 1:1 mixture of RB monomers and dimers. Studies of the singlet oxygen‐mediated RB2− self‐photosensitized bleaching indicated that the RB dimer is not a photosensitizer, suggesting that the efficiency of tissue protein crosslinking may be enhanced by blocking RB2− dimerization.
We demonstrate the highest resolution (1.5×1.5×1 µm) micrometer optical coherence tomography (µOCT) imaging of the morphologic micro-structure of excised swine and non-human primate corneas. Besides ...epithelial, stromal, and endothelial cell morphology, this report focuses on investigating the most peripheral corneal nerve fibers, the nerve fibers of the subbasal plexus (SBP). Alterations of SBP nerve density and composition are reportedly linked to major neurologic disorders, such as diabetic neuropathy, potentially indicating earliest onsets of denervation. Here, the fine, hyperreflective, epithelial nerve structures located just above Bowman’s membrane, are i) visualized using our µOCT prototype, ii) validated by comparison to fluorescence confocal microscopy (including selective immunohistochemical staining), and iii) segmented using state-of-the-art image processing. Here, we also introduce polarization sensitive (PS) µOCT imaging, demonstrating, to the best of our knowledge, the highest resolution corneal PS-OCT scans reported to date.
To evaluate a new non-ablative and adjustable procedure for laser ablative refractive corneal surgery in hyperopia using the injection of a biocompatible liquid filler material into a stromal pocket.
...A total of 120 stromal pockets were created using a clinical femtosecond laser system in 96 rabbit corneoscleral discs and 24 whole globes. Pockets were cut at a depth of 120 or 250 µm below the epithelial surface. Hyaluronic acid was injected manually into the pocket. To determine the refractive changes, three-dimensional optical coherence tomography images and a specifically developed picture recognition Matlab (The Mathworks) routine were used.
After injection, a steepening of the anterior and flattening of the posterior corneal surface was observed, which led to hyperopic correction. The two main factors determining the amount of correction were the pocket depth and the injected volume. After the pocket was homogeneously filled, an initial refractive increase was observed, followed by a linear relation between the injected volume and the refraction increase.
This possible clinical protocol for controlled refraction correction of hyperopia suggests a potential readjustable clinical application. J Refract Surg. 2020;36(6):406-414..
AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a ...plate haptic toric IOL.
METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA).
RESULTS: Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed.
CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.
Purpose:
In this study, we propose a method to grade corneal stromal opacity using optical density measurements by anterior segment optical coherence tomography (AS-OCT) and validate the approach in ...Fuchs endothelial corneal dystrophy (FECD).
Methods:
A retrospective analysis of human corneal OCT scans was performed on 48 eyes of 32 patients with FECD and 33 control eyes of 21 patients using the Carl Zeiss Cirrus HD-OCT 5000. In addition, corneal edema in fresh rabbit cadaver eyes was artificially induced by distilled water and imaged with the Thorlabs TELESTO-II spectral domain OCT at different time points during saturation. The increase of opacity due to corneal edema was proposed to directly correlate with enhanced reflectivity sites in the OCT images, corresponding to higher optical density. The increase was determined as the image area above a statistically established gray-scale value using ImageJ and correlated with other disease characteristics.
Results:
Optical densities in human corneas showed significant differences between FECD patients and the control group (p = 0.002). The increased optical densities determined in FECD corneas correlated well with other disease characteristics such as corneal pachymetry or visual acuity. Likewise, rabbit corneas showed a time dependent increase in thickness and in corneal optical density during soaking in distilled water.
Conclusion:
This study presents corneal optical density by AS-OCT as an objective value for corneal changes in FECD. Complementing other diagnostic tools in FECD the assessment of corneal optical density may identify progression of FECD, gauge novel therapeutic strategies and support risk and benefit analyses for corneal surgery.
This retrospective, single-center study evaluates the safety and efficacy of PreserfloTM MicroShunt (MicroShunt) implantations compared to trabeculectomies (TETs) in patients diagnosed with ...pseudoexfoliation glaucoma (PEXG). A total of 31 eyes from 28 patients received a MicroShunt implantation, and 29 eyes from 26 patients received a TET. Surgical success was defined as an intraocular pressure (IOP) between 5 mmHg and 17 mmHg at the end of the follow-up period, no need for surgical revisions or secondary glaucoma surgery, and no loss of light perception. In the MicroShunt group, the mean IOP dropped from 20.8 ± 5.9 mmHg at baseline to 12.4 ± 2.8 mmHg (p < 0.0001) after one year. In the TET group, the mean IOP dropped from 22.3 ± 6.5 mmHg to 11.1 ± 3.7 mmHg (p < 0.0001) after 12 months. In both of the groups, the mean number of medications was reduced significantly (MicroShunt from 2.7 ± 1.2 to 0.2 ± 0.7; p < 0.0001 vs. TET from 2.9 ± 1.2 to 0.3 ± 0.9; p < 0.0001). Considering the success rates, 83.9% of the MicroShunt eyes achieved complete success, and 90.3% qualified for success at the end of the follow-up period. In the TET group, the rates were 82.8% and 93.1%, respectively. The postoperative complications were comparable between both groups. In conclusion, the MicroShunt implantation demonstrated non-inferiority regarding its efficacy and safety profile compared to TET in PEXG at a follow-up of one year.
Ectasia screening in candidates for laser refractive surgery is mandatory during preoperative evaluation. Despite the availability of modern imaging techniques, refractive surgeons often face ...borderline decisions when patients present with suspicious tomographic findings. This case series presents refractive candidates with suspicious tomographic findings and demonstrates how to interpret them using Scheimpflug imaging and additional anterior segment optical coherence tomography (AS-OCT).PurposeEctasia screening in candidates for laser refractive surgery is mandatory during preoperative evaluation. Despite the availability of modern imaging techniques, refractive surgeons often face borderline decisions when patients present with suspicious tomographic findings. This case series presents refractive candidates with suspicious tomographic findings and demonstrates how to interpret them using Scheimpflug imaging and additional anterior segment optical coherence tomography (AS-OCT).Department of Ophthalmology, University Hospital, LMU Munich.SettingDepartment of Ophthalmology, University Hospital, LMU Munich.This case series examines six potential candidates for refractive surgery with a mean age of 29.2 ± 3.9 years, whose corneal assessments using Scheimpflug imaging raised suspicion for ectasia. Each candidate was additionally examined with AS-OCT and reevaluated. The mean manifest subjective spherical equivalent was -3.67 ± 1.8 diopters. The total corneal thickness measured 537 µm ± 30 µm at its thinnest point. None of the candidates had any reported underlying corneal or ophthalmic diseases, and slit lamp examinations revealed no abnormal morphological findings.Case seriesThis case series examines six potential candidates for refractive surgery with a mean age of 29.2 ± 3.9 years, whose corneal assessments using Scheimpflug imaging raised suspicion for ectasia. Each candidate was additionally examined with AS-OCT and reevaluated. The mean manifest subjective spherical equivalent was -3.67 ± 1.8 diopters. The total corneal thickness measured 537 µm ± 30 µm at its thinnest point. None of the candidates had any reported underlying corneal or ophthalmic diseases, and slit lamp examinations revealed no abnormal morphological findings.Both Scheimpflug imaging and AS-OCT are appropriate tools for screening refractive candidates for ectasia. While topographic and elevation analyses yielded comparable results regarding corneal structure, the epithelial mapping provided by AS-OCT played a critical role in decision-making for cases with borderline tomographic findings. Establishing a global consensus on the use of epithelial mapping in ectasia screening is necessary.ConclusionsBoth Scheimpflug imaging and AS-OCT are appropriate tools for screening refractive candidates for ectasia. While topographic and elevation analyses yielded comparable results regarding corneal structure, the epithelial mapping provided by AS-OCT played a critical role in decision-making for cases with borderline tomographic findings. Establishing a global consensus on the use of epithelial mapping in ectasia screening is necessary.