To explore the effect of the Affordable Care Act (ACA) on disparities in access to health care based on disability status, as well as age, income, race, and ethnicity.
In this study, I used logistic ...regression to analyze nationally representative data from 128 000 respondents to the US National Health Interview Survey from 2008 to 2010 and 2015 to 2017. Outcome variables were uninsurance over the previous 12 months, delayed or forgone health care for reasons of cost, and having a regular provider at a doctor's office or health clinic.
Over the period when the ACA was implemented, large existing disparities in access to health care were reduced for people with certain types of disabilities, young adults aged 19 to 25 years, and low-income families.
The ACA improved overall access to health care and reduced some disparities, but substantial disparities persist. Disability status remains associated with much greater risk of delayed or forgone care, and mental health disability is associated with greater likelihood of uninsurance.
The ACA partially achieved its goals and must not be weakened or rolled back. Further policy efforts are needed to address the remaining disparities.
To determine the horizontal extent of the binocular visual field (BVF) in subjects with horizontal strabismus and whether the BVF falls below the driving standard.
Adults with congenital esotropia ...and infantile exotropia ≤45 Prism Dioptres (PD), and subjects with orthotropia were recruited. The manifest angle of deviation was measured using a simultaneous prism cover test. Monocular Visual Field (MVF) and BVF were measured using the Esterman visual field test. Subjects with diplopia or a manifest angle of strabismus that varied by>8PD or the present of a vertical tropia >8PD were excluded.
Forty-nine subjects were included: 10 with orthotropia, 20 with exotropia and 19 with esotropia. The horizontal extent of BVF (degrees) was significantly smaller in esotropes (122.8 ± 18.8) than in orthotropes (141 ± 6.6) or exotropes (138.3 ± 8.3) (p < 0.01). In 6 (31.6%) subjects with an esotropia, the BVF was below the driving standard. The horizontal extent of the visual field (VF) of the amblyopic eyes of patients with esotropia (98.70 degrees, SD 19.76) and exotropia (104.75 degrees, SD16.93) were significantly smaller than those with orthotropia (121.00 degrees SD 3.16) by 22.3 degrees (p = 0.004) and 16.25 degrees (p = 0.045), respectively. The difference between the summation of MVFs and the BVF was significantly greater in orthotropes (100.6 ± 2.7) than in exotropes (68.9 ± 34.4) and esotropes (74.2 ± 20.7) (p < 0.01).
The horizontal extent of BVF is significantly smaller and more variable in adults with congenital esotropia and may fall below the driving standard.
Largest study on visual fields in subjects with horizontal strabismus including an orthotropic control group who do not have diplopia and who would otherwise meet the driving standard. Visual field quality was high but limitation is that visual field repeatability was not undertaken.
The findings of this study would suggest that people with an esotropia should be offered the opportunity to have a binocular visual field test before applying for a driving license. The DVLA may want to consider requesting people with an esotropia to have a binocular visual field test as is a requirement with other ophthalmic conditions such as glaucoma.
To provide a solution for average paraxial lens power (A
P) of a lens. Orthogonal and oblique sections through a lens of power Formula: see text were reduced to a paraxial representation of lens ...power followed by integration. Visual acuity was measured using lenses of different powers (cylinders of - 1.0 and - 2.0D) and axes, mean spherical equivalent (MSE) of S + C/2, A
P and a toric correction, with the order of correction randomised. A digital screen at 6 m was used on which a Landolt C with crowding bars was displayed for 0.3 s before vanishing. The general equation for a symmetrical lens of refractive index (n), radius of curvature R, in medium of refractive index n1, through orthogonal (Formula: see text) and oblique meridians (Formula: see text) as a function of the angle of incidence (Formula: see text) reduces for paraxial rays (Formula: see text) to Formula: see text. The average of this function is Formula: see text providing a solution of Formula: see text for A
P.For central (p = 0.04), but not peripheral (p = 0.17) viewing, correction with A
P was associated with better visual acuity than a MSE across all tested refractive errors (p = 0.04). These findings suggest that Formula: see text may be a more inclusive representation of the average paraxial power of a cylindrical lens than the MSE.
To evaluate the effect of preoperative posturing on subfoveal fluid height (SFFH) in macula-off retinal detachment (RD).
Prospective study including patients with macula-off RD with SFFH measurable ...on optical coherence tomography (OCT) and duration of loss of central vision (LCV) ≤ 7 days. Linear OCT volume scans were performed at baseline, after one minute, one hour, four hours and on the next morning. For the first hour all patients remained in an upright position. Patients were then either instructed to posture until the surgery according to the location of the primary retinal break (posturing group) or were not given any instructions (control group).
Twenty-four patients were included in the posturing group and 11 patients in the control group. There was no significant change in SFFH between baseline, 1 minute, 1 hour and 4 hours. Mean SFFH in the control group increased by 243 µm from 624 (±268) µm at baseline to 867 (±303) µm the next morning (p<0.01) but decreased in the posturing group by 150 µm from 728 (±416) to 578 (±445) µm (p=0.03). There was a significant association of the SFFH the next morning with posturing (p<0.01) and SFFH at baseline (p<0.01), but not with location of primary break (p=0.20). The change in SFFH from baseline to the next morning was significantly associated with posturing and primary break location (p<0.01) but not with SFFH at baseline (p=0.21).
Preoperative posturing is an effective measure to prevent progression of macular detachment in macula-off RD.
Extracellular vesicles (EVs), specifically exosomes, carry a cell-type dependent cargo that is transported to the recipient cell and translated in the presence of a required machinery. Differences in ...the cargo carried by the corneal and conjunctival-derived EVs could be the agent that triggers the transdifferentiation of these two cell populations. Therefore, this study investigates the role of EVs in triggering the plasticity of corneal and conjunctival epithelial cells and identifies prospective miRNA and genes responsible for maintaining ocular surface homeostasis. The EVs were extracted from the conditioned media (after starving) of corneal epithelial (hTCEpi) and conjunctival (HCjE-Gi) cell lines using ultracentrifugation. HCjE-Gi cells were cultured with hTCEpi-derived EVs and vice-versa. The EVs were characterized as exosomes using Nanosight and Flow cytometry. KRT3 and KRT12 were used as associated corneal markers, whereas KRT7 and KRT13 were used as associated conjunctival markers with ΔNp63 as a differentiation marker. Shift of these markers was an indication of transdifferentiation. The cargo of the extracted exosomes from both the cell types was explored using next-generation sequencing. The hTCEpi-derived EVs induced conjunctival epithelial cells to express the corneal-associated markers KRT3 and KRT12, losing their conjunctival phenotype at both the mRNA and protein level. Simultaneously, HCjE-Gi-derived EVs induced corneal epithelial cells to express the conjunctival associated markers KRT7 and KRT13, losing their corneal phenotype. This process of differentiation was accompanied by an intermediate step of cell de-differentiation showed by up-regulation in the expression of epithelial stem cell marker ΔNp63, also shown on the ex vivo human cadaveric donor corneas. miRNA molecules (total of 11 including precursor and mature) with significant differences in their relative abundance between the two populations (
< 0.05) were found and investigated. miR-9-5p expression was higher in HCjE-Gi cells and HCjE-Gi-derived EVs when compared to hTCEpi cells and hTCEPi-derived EVs (
< 0.001). The results suggest that EVs released by the two cell types have the ability to influence the transdifferentiation of human conjunctival and corneal epithelial cells. miR-9-5p could have a role in stem cell homeostasis and cell differentiation via
gene.
While for the ApP, the average is the average of orthogonal and oblique paraxial rays, that is, ApP=average orthogonal and oblique paraxial power F¯ApP(orthogonal+oblique), ...F¯ApP(orthogonal+oblique)=C14+C14+C2−C14, ApP=F¯ApP(orthogonal+oblique)=C14+C24. ...the ApP is equal to half the SE if calculated in cross cylinder form, that is, ApP=SE2. If a refractive error, however, does comprise a true spherical component, then the average of that component is of course the sphere. ...for a refractive power that contains a sphere, the ApP=Sphere+C4 and the SE=Sphere+C2 and the difference between the ApP and SE is equal to C4 . The ApP as a scalar measure is more inclusive and appears to be associated with better visual acuity than the SE, although further clinical trials are needed particularly in different age groups and conditions.
To investigate the role of an internal limiting membrane (ILM) flap in macular hole (MH) surgery on closure rate, visual acuity, and integrity of the outer retinal layers.
Retrospective, ...nonrandomized interventional analysis in which 117 eyes of 117 patients were included who had undergone pars-plana vitrectomy (PPV) and gas tamponade for primary idiopathic MH >400 µm with either conventional ILM peeling or with inverted ILM flap technique at The Royal Liverpool University Hospital between January 2016 and April 2018. Main outcome measures were closure of MH, best-corrected visual acuity (BCVA) at 3, 6, and 12 months, and restoration of external limiting membrane and ellipsoid zone (EZ) using optical coherence tomography.
Macular hole closure rate was significantly higher in patients with an ILM flap (67/68; 98.53%) than in those with conventional ILM peeling (43/49; 87.76%) (P = 0.02). Both groups showed significant improvements in their preoperative to postoperative BCVA at 3 months from 1.07 (0.43) logarithm of the minimum angle of resolution (logMAR) (20/235 Snellen) to 0.71 (0.34) logMAR (20/103 Snellen) (P <0.001), but there was no significant difference between the two groups (P = 0.45, P = 0.71). We found significant associations between postoperative BCVA and preoperative BCVA (P < 0.01) and the integrity of the EZ (P < 0.01). In 35 patients who had follow-up to 12 months, there was a significant improvement in BCVA between 3, 6, and 12 months from 0.73 (0.45) logMAR (20/107 Snellen) to 0.53 (0.24) logMAR (20/68 Snellen) and to 0.35 (0.18) logMAR (20/45 Snellen), respectively (P < 0.01). There was no significant difference at these time periods between the two groups (P = 0.62, P = 0.21, P = 0.31). The integrity of the EZ also improved significantly between 3, 6, and 12 months (P = 0.01), irrespective of the presence of an ILM flap (P = 0.58), but with a trend toward delay in restoration in those patients with an ILM flap. The improvement in BCVA at 12 months, taking into account the age of the patient, size and duration of the MH, presence of an ILM flap, and preoperative BCVA was dependent on the state of the EZ (P = 0.01).
In patients undergoing primary pars-plana vitrectomy for MH >400 µm, the presence of an inverted ILM flap was associated with a significantly higher closure rate than a conventional ILM peeling. Best-corrected visual acuity showed a strong correlation with the integrity of the EZ and both improved significantly between 3, 6, and 12 months, irrespective of the presence of an ILM flap.
To report early corneal biomechanical changes after corneal cross-linking (CXL) in patients with keratoconus.
Thirty-four eyes of 34 patients undergoing CXL for progressive keratoconus were included ...in this prospective clinical study. Dynamic corneal response (DCR) parameters obtained with the Corvis ST (OCULUS Optikgeräte GmbH; Wetzlar, Germany) were assessed at baseline (day of CXL) and after 1 month of follow-up; conversely, corneal tomography with the Pentacam (OCULUS Optikgeräte GmbH) was assessed at baseline and at 1, 3, and 6 months after CXL.
At the last follow-up visit (123.7 ± 69.6 days), all morphological parameters including steepest point (Kmax) and thinnest corneal thickness (ThCT) indicated stabilization of keratoconus (P > .05). Comparative analyses showed a rise of corneal stiffness demonstrated by a significant increase of Stiffness Parameter A1 (SP-A1) and Highest Concavity (SP-HC) and a significant decrease of Inverse Concave Radius (1/R) and Deformation Amplitude Ratio (DA Ratio) (P < .05). There was a significant correlation between the preoperative keratoconus characteristics (Kmax, Belin/Ambrósio final D value BAD-D, and ThCT) and the DCR parameters (P < .05). Kmax and BAD-D showed a significant positive correlation with DA Ratio, Deflection Amplitude (DefA), and 1/R and a significant negative correlation with SPA1 and SP-HC. ThCT showed a significant positive correlation with SP-A1 and SP-HC and a significant negative correlation with DA Ratio, DefA, and 1/R.
This study suggests that the new DCR parameters of the Corvis ST are able to detect early changes in biomechanics following CXL and those that are measurable before corneal shape modifications take place. Based on these results, the authors suggest the use of these metrics to assess the early efficacy of cross-linking. J Refract Surg. 2017;33(12):840-846..