How much of the structure of the human mind and brain is already specified at birth, and how much arises from experience? In this article, we consider the test case of extrastriate visual cortex, ...where a highly systematic functional organization is present in virtually every normal adult, including regions preferring behaviourally significant stimulus categories, such as faces, bodies, and scenes. Novel methods were developed to scan awake infants with fMRI, while they viewed multiple categories of visual stimuli. Here we report that the visual cortex of 4-6-month-old infants contains regions that respond preferentially to abstract categories (faces and scenes), with a spatial organization similar to adults. However, precise response profiles and patterns of activity across multiple visual categories differ between infants and adults. These results demonstrate that the large-scale organization of category preferences in visual cortex is adult-like within a few months after birth, but is subsequently refined through development.
Since the advent of magnetic resonance imaging (MRI) nearly four decades ago, there has been a quest for ever-higher magnetic field strengths. Strong incentives exist to do so, as increasing the ...magnetic field strength increases the signal-to-noise ratio of images. However, ensuring patient safety becomes more challenging at high and ultrahigh field MRI (i.e., ≥3 T) compared to lower fields. The problem is exacerbated for patients with conductive implants, such as those with deep brain stimulation (DBS) devices, as excessive local heating can occur around implanted lead tips. Despite extensive effort to assess radio frequency (RF) heating of implants during MRI at 1.5 T, a comparative study that systematically examines the effects of field strength and various exposure limits on RF heating is missing.
This study aims to perform numerical simulations that systematically compare RF power deposition near DBS lead models during MRI at common clinical and ultra-high field strengths, namely 1.5, 3, 7, and 10.5 T. Furthermore, we assess the effects of different exposure constraints on RF power deposition by imposing limits on either the B1+ or global head specific absorption rate (SAR) as these two exposure limits commonly appear in MRI guidelines.
We created 33 unique DBS lead models based on postoperative computed tomography (CT) images of patients with implanted DBS devices and performed electromagnetic simulations to evaluate the SAR of RF energy in the tissue surrounding lead tips during RF exposure at frequencies ranging from 64 MHz (1.5 T) to 447 MHz (10.5 T). The RF exposure was implemented via realistic MRI RF coil models created based on physical prototypes built in our institutions. We systematically examined the distribution of local SAR at different frequencies with the input coil power adjusted to either limit the B1+ or the global head SAR.
The MRI RF coils at higher resonant frequencies generated lower SARs around the lead tips when the global head SAR was constrained. The trend was reversed when the constraint was imposed on B1+.
At higher static fields, MRI is not necessarily more dangerous than at lower fields for patients with conductive leads. Specifically, when a conservative safety criterion, such as constraints on the global SAR, is imposed, coils at a higher resonant frequency tend to generate a lower local SAR around implanted leads due to the decreased B1+ and, by proxy, E field levels.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Patients with deep brain stimulation (DBS) implants can significantly benefit from magnetic resonance imaging (MRI), however access to MRI is restricted in these patients because of safety concerns ...due to RF heating of the leads. Recently we introduced a patient-adjustable reconfigurable transmit coil for low-SAR imaging of DBS at 1.5T. A previous simulation study demonstrated a substantial reduction in the local SAR around single DBS leads in 9 unilateral lead models. This work reports the first experimental results of temperature measurement at the tips of bilateral DBS leads with realistic trajectories extracted from postoperative CT images of 10 patients (20 leads in total). A total of 200 measurements were performed to record temperature rise at the tips of the leads during 2 minutes of scanning with the coil rotated to cover all accessible rotation angles. In all patients, we were able to find an optimum coil rotation angle and reduced the heating of both left and right leads to a level below the heating produced by the body coil. An average heat reduction of 65% was achieved for bilateral leads. When considering each lead alone, an average heat reduction of 80% was achieved. Our results suggest that reconfigurable coil technology introduces a promising approach for imaging of patients with DBS implants.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The engineering of a 3T human MRI scanner equipped with 300mT/m gradients – the strongest gradients ever built for an in vivo human MRI scanner – was a major component of the NIH Blueprint Human ...Connectome Project (HCP). This effort was motivated by the HCP's goal of mapping, as completely as possible, the macroscopic structural connections of the in vivo healthy, adult human brain using diffusion tractography. Yet, the 300mT/m gradient system is well suited to many additional types of diffusion measurements. Here, we present three initial applications of the 300mT/m gradients that fall outside the immediate scope of the HCP. These include: 1) diffusion tractography to study the anatomy of consciousness and the mechanisms of brain recovery following traumatic coma; 2) q-space measurements of axon diameter distributions in the in vivo human brain and 3) postmortem diffusion tractography as an adjunct to standard histopathological analysis. We show that the improved sensitivity and diffusion-resolution provided by the gradients are rapidly enabling human applications of techniques that were previously possible only for in vitro and animal models on small-bore scanners, thereby creating novel opportunities to map the microstructure of the human brain in health and disease.
•Diffusion spectrum imaging to study traumatic coma recovery•In vivo human axon diameter measurements using 300mT/m gradients•High-resolution (0.6mm isotropic) diffusion imaging in whole, fixed human brain
Tremendous efforts have been made in the last decade to advance cutting-edge MRI technology in pursuit of mapping structural connectivity in the living human brain with unprecedented sensitivity and ...speed. The first Connectom 3T MRI scanner equipped with a 300 mT/m whole-body gradient system was installed at the Massachusetts General Hospital in 2011 and was specifically constructed as part of the Human Connectome Project. Since that time, numerous technological advances have been made to enable the broader use of the Connectom high gradient system for diffusion tractography and tissue microstructure studies and leverage its unique advantages and sensitivity to resolving macroscopic and microscopic structural information in neural tissue for clinical and neuroscientific studies. The goal of this review article is to summarize the technical developments that have emerged in the last decade to support and promote large-scale and scientific studies of the human brain using the Connectom scanner. We provide a brief historical perspective on the development of Connectom gradient technology and the efforts that led to the installation of three other Connectom 3T MRI scanners worldwide – one in the United Kingdom in Cardiff, Wales, another in continental Europe in Leipzig, Germany, and the latest in Asia in Shanghai, China. We summarize the key developments in gradient hardware and image acquisition technology that have formed the backbone of Connectom-related research efforts, including the rich array of high-sensitivity receiver coils, pulse sequences, image artifact correction strategies and data preprocessing methods needed to optimize the quality of high-gradient strength diffusion MRI data for subsequent analyses. Finally, we review the scientific impact of the Connectom MRI scanner, including advances in diffusion tractography, tissue microstructural imaging, ex vivo validation, and clinical investigations that have been enabled by Connectom technology. We conclude with brief insights into the unique value of strong gradients for diffusion MRI and where the field is headed in the coming years.
The main objective of this study was to utilize high field (7T) in vivo proton magnetic resonance imaging to increase the ability to detect metabolite changes in people with ALS, specifically, to ...quantify levels of glutamine and glutamine separately. The second objective of this study was to correlate metabolic markers with clinical outcomes of disease progression. 13 ALS participants and 12 age-matched healthy controls (HC) underwent 7 Tesla MRI and MRS. Single voxel MR spectra were acquired from the left precentral gyrus using a very short echo time (TE = 5 ms) STEAM sequence. MRS data was quantified using LCModel and correlated to clinical outcome markers. N-acetylaspartate (NAA) and total NAA (tNA, NAA + NAAG) were decreased by 17% in people with ALS compared to HC (P = 0.004 and P = 0.005, respectively) indicating neuronal injury and/or loss in the precentral gyrus. tNA correlated with disease progression as measured by forced vital capacity (FVC) (P = 0.014; Rρ = 0.66) and tNA/tCr correlated with overall functional decline as measured by worsening of the ALS Functional Rating Scale-Revised (ALSFRS-R) (P = 0.004; Rρ = -0.74). These findings underscore the importance of NAA as a reliable biomarker for neuronal injury and disease progression in ALS. Glutamate (Glu) was 15% decreased in people with ALS compared to HC (P = 0.02) while glutamine (Gln) concentrations were similar between the two groups. Furthermore, the decrease in Glu correlated with the decrease in FVC (P = 0.013; Rρ = 0.66), a clinical marker of disease progression. The decrease in Glu is most likely driven by intracellular Glu loss due to neuronal loss and degeneration. Neither choline containing components (Cho), a marker for cell membrane turnover, nor myo-Inositol (mI), a suspected marker for neuroinflammation, showed significant differences between the two groups. However, mI/tNA was correlated with upper motor neuron burden (P = 0.004, Rρ = 0.74), which may reflect a relative increase of activated microglia around motor neurons. In summary, 7T 1H MRS is a powerful non-invasive imaging technique to study molecular changes related to neuronal injury and/or loss in people with ALS.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, ...which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b-value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-channel head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability and advantage of the developed coil for high-resolution and high b-value diffusion-weighted ex vivo brain MRI studies.
The goal of this study was to examine a new weightless-like radiation protection garment regarding its radiation protection efficacy and to compare it to a conventional two-piece apron suit plus ...thyroid collar and standard ancillary shields.
All measurements were carried out using a clinical angiography system with a standardized fluoroscopy protocol for different C-arm angulations. An anthropomorphic torso phantom served as a scattering body. In addition, an ionization chamber was used to measure the radiation exposure on five different representative heights and at two different positions of an examiner during a typical fluoroscopic-guided intervention.
The new weightless-like radiation protection garment and the conventional protection concept showed a mean dose reduction of 98.1% (p < 0.01) and 90.1% (p < 0.01) when compared to no shielding, respectively. By adding ancillary shields to both systems, an average reduction of 99.0% (p < 0.01) and 98.2% (p < 0.01) was found. In addition, the efficacy of both systems varied depending on the height, the C-arm angulation and position of the examiner.
Combined with ancillary shields as an overall protection system, the recently introduced weightless-like radiation protection garment showed a significant better radiation protection efficacy when compared to conventional radiation protection measures.
Strong overexpression of glucagonlike peptide-1 (GLP-1) receptors in human insulinoma provides an attractive target for imaging. The first clinical trials demonstrated that GLP-1 receptor SPECT/CT ...using Lys(40)(Ahx 6-aminohexanoic acid-DOTA-(111)In)NH(2)-exendin-4 can localize hardly detectable insulinomas. However, Lys(40)(Ahx-DOTA-(111)In)NH(2)-exendin-4 imaging has drawbacks related to the use of (111)In in that it is costly and carries a relatively high radiation burden for the patient. The aim of this study was the preclinical evaluation of Lys(40)(Ahx-DOTA-(68)Ga)NH(2)-exendin-4 for PET/CT and Lys(40)(Ahx-hydrazinonicotinamide HYNIC-(99m)Tc)NH(2)-exendin-4 for SPECT/CT.
Internalization, biodistribution, dosimetry, and imaging studies were performed in the Rip1Tag2 mouse model of pancreatic beta-cell carcinogenesis and compared with our gold standard Lys(40)(Ahx-DOTA-(111)In)NH(2)-exendin-4. Poly-glutamic acid and Gelofusine, a gelatin-based plasma expander, were used for renal uptake reduction studies.
The tumor uptake of Lys(40)(Ahx-DOTA-(68)Ga)NH(2)-exendin-4 was 205 +/- 59 percentage injected activity per gram of tissue at 4 h. Other GLP-1 receptor-positive organs showed more than 4.8 times lower radioactivity uptake. Lys(40)(Ahx-HYNIC-(99m)Tc/ethylenediaminediacetic acid EDDA)NH(2)-exendin-4, compared with its (111)In- and (68)Ga-labeled sister compounds, showed significantly less tumor and organ uptake. The significantly lower tumor and organ uptake of Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH(2)-exendin-4 did not result in inferior tumor-to-organ ratios or reduced image quality. All radiopeptides tested showed a high tumor-to-background ratio, resulting in the visualization of small tumors (maximum diameter between 1.0 and 3.2 mm) by SPECT and PET. The only exception was the kidneys, which also showed high uptake. This uptake could be reduced by 49%-78% using poly-glutamic acid, Gelofusine, or a combination of the 2. The estimated effective radiation dose was 3.7 muSv/MBq for Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH(2)-exendin-4, which was 8 times less than that for Lys(40)(Ahx-DOTA-(68)Ga)NH(2)-exendin-4 and 43 times less than that for Lys(40)(Ahx-DOTA-(111)In)NH(2)-exendin-4.
These promising pharmacokinetic and imaging data show that Lys(40)(Ahx-DOTA-(68)Ga)NH(2)-exendin-4 and Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH(2)-exendin-4 are suitable candidates for clinical GLP-1 receptor imaging studies.