The goal of this study is to determine how H2O and HDO measurements in water vapor can be used to detect and diagnose biases in the representation of processes controlling tropospheric humidity in ...atmospheric general circulation models (GCMs). We analyze a large number of isotopic data sets (four satellite, sixteen ground‐based remote‐sensing, five surface in situ and three aircraft data sets) that are sensitive to different altitudes throughout the free troposphere. Despite significant differences between data sets, we identify some observed HDO/H2O characteristics that are robust across data sets and that can be used to evaluate models. We evaluate the isotopic GCM LMDZ, accounting for the effects of spatiotemporal sampling and instrument sensitivity. We find that LMDZ reproduces the spatial patterns in the lower and mid troposphere remarkably well. However, it underestimates the amplitude of seasonal variations in isotopic composition at all levels in the subtropics and in midlatitudes, and this bias is consistent across all data sets. LMDZ also underestimates the observed meridional isotopic gradient and the contrast between dry and convective tropical regions compared to satellite data sets. Comparison with six other isotope‐enabled GCMs from the SWING2 project shows that biases exhibited by LMDZ are common to all models. The SWING2 GCMs show a very large spread in isotopic behavior that is not obviously related to that of humidity, suggesting water vapor isotopic measurements could be used to expose model shortcomings. In a companion paper, the isotopic differences between models are interpreted in terms of biases in the representation of processes controlling humidity.
Key Points
Isotopic evaluation with in situ, satellite, ground‐based remote‐sensing data
Consistent features and model‐data differences across data sets
Isotopic GCMs share common biases
We used temperature data from the Michelson Interferometer for Passive Atmospheric Sounding on board ESA's Envisat satellite to analyze the temperature responses in the mesosphere and thermosphere up ...to 170 km to a major stratospheric sudden warming (SSW) which occurred in January 2009. The temperature observations show clear signatures of a mesospheric cooling and a thermospheric warming, the latter peaking at 120–140 km in agreement with model predictions. From the analysis of the zonal temperature structure during the SSW a pronounced wave 1 pattern was found in the entire middle and upper polar atmosphere with maximum amplitudes around 50 and 140 km. In the mesosphere, the wave amplitude is significantly damped. The wave amplification above is most likely produced by in situ forced planetary waves in the mesosphere and lower thermosphere region. Our observations represent the first experimental evidence of a dynamical coupling of the lower atmosphere and the thermosphere in the 120–150 km range by means of satellite data.
Drifts, trends and periodic variations were calculated from monthly zonally averaged ozone profiles. The ozone profiles were derived from level-1b data of the Michelson Interferometer for Passive ...Atmospheric Sounding (MIPAS) by means of the scientific level-2 processor run by the Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK). All trend and drift analyses were performed using a multilinear parametric trend model which includes a linear term, several harmonics with period lengths from 3 to 24 months and the quasi-biennial oscillation (QBO). Drifts at 2-sigma significance level were mainly negative for ozone relative to Aura MLS and Odin OSIRIS and negative or near zero for most of the comparisons to lidar measurements. Lidar stations used here include those at Hohenpeissenberg (47.8° N, 11.0° E), Lauder (45.0° S, 169.7° E), Mauna Loa (19.5° N, 155.6° W), Observatoire Haute Provence (43.9° N, 5.7° E) and Table Mountain (34.4° N, 117.7° W). Drifts against the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) were found to be mostly insignificant. The assessed MIPAS ozone trends cover the time period of July 2002 to April 2012 and range from −0.56 ppmv decade−1 to +0.48 ppmv decade−1 (−0.52 ppmv decade−1 to +0.47 ppmv decade−1 when displayed on pressure coordinates) depending on altitude/pressure and latitude. From the empirical drift analyses we conclude that the real ozone trends might be slightly more positive/less negative than those calculated from the MIPAS data, by conceding the possibility of MIPAS having a very small (approximately within −0.3 ppmv decade−1) negative drift for ozone. This leads to drift-corrected trends of −0.41 ppmv decade−1 to +0.55 ppmv decade−1 (−0.38 ppmv decade−1 to +0.53 ppmv decade−1 when displayed on pressure coordinates) for the time period covered by MIPAS Envisat measurements, with very few negative and large areas of positive trends at mid-latitudes for both hemispheres around and above 30 km (~10 hPa). Negative trends are found in the tropics around 25 and 35 km (~25 and 5 hPa), while an area of positive trends is located right above the tropical tropopause. These findings are in good agreement with the recent literature. Differences of the trends compared with the recent literature could be explained by a possible shift of the subtropical mixing barriers. Results for the altitude–latitude distribution of amplitudes of the quasi-biennial, annual and the semi-annual oscillation are overall in very good agreement with recent findings.
Vertically resolved distributions of sulfur dioxide (SO2) with global coverage in the height region from the upper troposphere to ~20 km altitude have been derived from observations by the Michelson ...Interferometer for Passive Atmospheric Sounding (MIPAS) on Envisat for the period July 2002 to April 2012. Retrieved volume mixing ratio profiles representing single measurements are characterized by typical errors in the range of 70-100 pptv and by a vertical resolution ranging from 3 to 5 km. Comparison with observations by the Atmospheric Chemistry Experiment Fourier transform spectrometer (ACE-FTS) revealed a slightly varying bias with altitude of -20 to 50 pptv for the MIPAS data set in case of volcanically enhanced concentrations. For background concentrations the comparison showed a systematic difference between the two major MIPAS observation periods. After debiasing, the difference could be reduced to biases within -10 to 20 pptv in the altitude range of 10-20 km with respect to ACE-FTS. Further comparisons of the debiased MIPAS data set with in situ measurements from various aircraft campaigns showed no obvious inconsistencies within a range of around plus or minus 50 pptv. The SO2 emissions of more than 30 volcanic eruptions could be identified in the upper troposphere and lower stratosphere (UTLS). Emitted SO2 masses and lifetimes within different altitude ranges in the UTLS have been derived for a large part of these eruptions. Masses are in most cases within estimations derived from other instruments. From three of the major eruptions within the MIPAS measurement period - Kasatochi in August 2008, Sarychev in June 2009 and Nabro in June 2011 - derived lifetimes of SO2 for the altitude ranges 10-14, 14-18 and 18-22 km are 13.3 plus or minus 2.1, 23.6 plus or minus 1.2 and 32.3 plus or minus 5.5 days respectively. By omitting periods with obvious volcanic influence we have derived background mixing ratio distributions of SO2. At 10 km altitude these indicate an annual cycle at northern mid- and high latitudes with maximum values in summer and an amplitude of about 30 pptv. At higher altitudes of about 16-18 km, enhanced mixing ratios of SO2 can be found in the regions of the Asian and the North American monsoons in summer - a possible connection to an aerosol layer discovered by Vernier et al. (2011b) in that region.
To develop a consensus statement for the prescription of a Powered Wheelchair Standing Device (PWSD) in young people with Duchenne muscular dystrophy (DMD).
An international multidisciplinary panel ...comprising clinicians and users (young people with DMD) along with their parents was consulted. A literature review was undertaken and a Delphi method was utilised to generate consensus statements. To supplement limited literature, round one of the Delphi process comprised questions consistent with the International Classification of Functioning, Disability and Health model of disability to generate items based on expert opinion and was completed by 38 clinicians and nine users. Thirty-seven participants completed two further rounds rating the importance of each item with a five-point scale. Agreement of 70% or more participants for items indicated consensus.
Consensus was reached for 47 of 80 items. Tolerance and comfort in supported standing for at least 10 min, ankle contracture less than 10 degrees and user goals reflecting motivation to use the standing function were agreed as necessary in guiding the decision to trial a PWSD. Evidence of family, therapist and servicing support were also considered critical in enabling continuity of PWSD use.
PWSD is a mobility option that offers choice, control and opportunity for independence. This consensus statement can assist clinicians with decision-making around factors influencing successful implementation and optimisation of PWSD for young people with DMD.
Implications for Rehabilitation
Tolerance and comfort in supported standing for at least 10 minutes, ankle contracture limited to less than 10 degrees and the child's goals reflecting motivation to use the standing position were agreed to be necessary considerations in guiding the decision to trial a PWSD.
Trialling a PWSD when the child is predicted to lose the ability to walk within a one to two year period was recommended although a PWSD could be suitable for a child who was unable to walk.
Evidence of family, therapist and servicing support was considered critical in enabling continuity of PWSD use.
Highlights ► We compared different repetitive TMS patterns that impair semantic processing. ► Continuous theta-burst with 90% AMT and 1 Hz rTMS with 100% RMT both increased reaction times. ► cTBS is ...more comfortable and might replace 1 Hz rTMS in virtual lesion studies.