Aging and ocular tissue stiffness in glaucoma Liu, Baiyun; McNally, Sara; Kilpatrick, Jason I. ...
Survey of ophthalmology,
January-February 2018, 2018 Jan - Feb, 2018-01-00, 20180101, Letnik:
63, Številka:
1
Journal Article
Recenzirano
Glaucoma is a progressive and chronic neurodegenerative disorder characterized by damage to the inner layers of the retina and deformation of the optic nerve head. The degeneration of retinal ...ganglion cells and their axons results in an irreversible loss of vision and is correlated with increasing age. Extracellular matrix changes related to natural aging generate a stiffer extracellular environment throughout the body. Altered age-associated ocular tissue stiffening plays a major role in a significant number of ophthalmic pathologies. In glaucoma, both the trabecular meshwork and the optic nerve head undergo extensive extracellular matrix remodeling, characterized by fibrotic changes associated with cellular and molecular events (including myofibroblast activation) that drive further tissue fibrosis and stiffening. Here, we review the literature concerning the role of age-related ocular stiffening in the trabecular meshwork, lamina cribrosa, sclera, cornea, retina, and Bruch membrane/choroid and discuss their potential role in glaucoma progression. Because both trabecular meshwork and lamina cribrosa cells are mechanosensitive, we then describe molecular mechanisms underlying tissue stiffening and cell mechanotransduction and how these cellular activities can drive further fibrotic changes within ocular tissues. An improved understanding of the interplay between age-related tissue stiffening and biological responses in the trabecular meshwork and optic nerve head could potentially lead to novel therapeutic strategies for glaucoma treatment.
Understanding the influence of water layers adjacent to interfaces is fundamental in order to fully comprehend the interactions of both biological and nonbiological materials in aqueous environments. ...In this study, we have investigated hydration forces at the mica–electrolyte interface as a function of ion valency and concentration using subnanometer oscillation amplitude frequency modulation atomic force microscopy (FM-AFM). Our results reveal new insights into the nature of hydration forces at interfaces due to our ability to measure high force gradients without instability and in the absence of lateral confinement due to the use of an atomically sharp tip. We demonstrate the influence of electrolytes on the properties of both primary and structural hydration forces and reveal new insights into the interplay between these phenomena in determining the interaction forces experienced by a nanoscale object approaching an interface. We also highlight the difficulty in directly comparing hydration force data from different measurement techniques where the nature of the perturbation induced by differing interaction geometries is likely to dramatically affect the results.
Fundamental mechanisms of energy storage, corrosion, sensing, and multiple biological functionalities are directly coupled to electrical processes and ionic dynamics at solid-liquid interfaces. In ...many cases, these processes are spatially inhomogeneous taking place at grain boundaries, step edges, point defects, ion channels, etc and possess complex time and voltage dependent dynamics. This necessitates time-resolved and real-space probing of these phenomena. In this review, we discuss the applications of force-sensitive voltage modulated scanning probe microscopy (SPM) for probing electrical phenomena at solid-liquid interfaces. We first describe the working principles behind electrostatic and Kelvin probe force microscopies (EFM & KPFM) at the gas-solid interface, review the state of the art in advanced KPFM methods and developments to (i) overcome limitations of classical KPFM, (ii) expand the information accessible from KPFM, and (iii) extend KPFM operation to liquid environments. We briefly discuss the theoretical framework of electrical double layer (EDL) forces and dynamics, the implications and breakdown of classical EDL models for highly charged interfaces or under high ion concentrations, and describe recent modifications of the classical EDL theory relevant for understanding nanoscale electrical measurements at the solid-liquid interface. We further review the latest achievements in mapping surface charge, dielectric constants, and electrodynamic and electrochemical processes in liquids. Finally, we outline the key challenges and opportunities that exist in the field of nanoscale electrical measurements in liquid as well as providing a roadmap for the future development of liquid KPFM.
In this paper, we derive and present quantitative expressions governing the performance of single and multifrequency Kelvin probe force microscopy (KPFM) techniques in both air and water. Metrics ...such as minimum detectable contact potential difference, minimum required AC bias, and signal-to-noise ratio are compared and contrasted both off resonance and utilizing the first two eigenmodes of the cantilever. These comparisons allow the reader to quickly and quantitatively identify the parameters for the best performance for a given KPFM-based experiment in a given environment. Furthermore, we apply these performance metrics in the identification of KPFM-based modes that are most suitable for operation in liquid environments where bias application can lead to unwanted electrochemical reactions. We conclude that open-loop multifrequency KPFM modes operated with the first harmonic of the electrostatic response on the first eigenmode offer the best performance in liquid environments whilst needing the smallest AC bias for operation.
Germanium nanowire (GeNW) electrodes have shown great promise as high-power, fast-charging alternatives to silicon-based electrodes, owing to their vastly improved Li ion diffusion, electron mobility ...and ionic conductivity. Formation of the solid electrolyte interphase (SEI) on the anode surface is critical to electrode performance and stability but is not completely understood for NW anodes. Here, a systematic study characterizing pristine and cycled GeNWs in charged and discharged states with SEI layer present and removed is performed using Kelvin probe force microscopy in air. Correlating changes in the morphology of the GeNW anodes with contact potential difference mapping at different cycles provides insight into SEI layer formation and growth, and the effect of the SEI on battery performance.
Surface potential mapping of Ge nanowire anodes showing the change in surface morphology and surface potential with solid electrolyte interphase layer formation during cycling.
Fibrous peptide networks, such as the structural framework of self-assembled fluorenylmethyloxycarbonyl diphenylalanine (Fmoc–FF) nanofibrils, have mechanical properties that could successfully mimic ...natural tissues, making them promising materials for tissue engineering scaffolds. These nanomaterials have been determined to exhibit shear piezoelectricity using piezoresponse force microscopy, as previously reported for FF nanotubes. Structural analyses of Fmoc–FF nanofibrils suggest that the observed piezoelectric response may result from the noncentrosymmetric nature of an underlying β-sheet topology. The observed piezoelectricity of Fmoc–FF fibrous networks is advantageous for a range of biomedical applications where electrical or mechanical stimuli are required.
Conventional closed loop-Kelvin probe force microscopy (KPFM) has emerged as a powerful technique for probing electric and transport phenomena at the solid-gas interface. The extension of KPFM ...capabilities to probe electrostatic and electrochemical phenomena at the solid-liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe-sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present). Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl) and ionically-inactive (non-polar decane) liquids by electrochemical force microscopy (EcFM), a multidimensional (i.e., bias- and time-resolved) spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids), KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD) values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions). EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid-liquid interface.
The behavior and mechanical properties of cells are strongly dependent on the biochemical and biomechanical properties of their microenvironment. Thus, understanding the mechanical properties of ...cells, extracellular matrices, and biomaterials is key to understanding cell function and to develop new materials with tailored mechanical properties for tissue engineering and regenerative medicine applications. Atomic force microscopy (AFM) has emerged as an indispensable technique for measuring the mechanical properties of biomaterials and cells with high spatial resolution and force sensitivity within physiologically relevant environments and timescales in the kPa to GPa elastic modulus range. The growing interest in this field of bionanomechanics has been accompanied by an expanding array of models to describe the complexity of indentation of hierarchical biological samples. Furthermore, the integration of AFM with optical microscopy techniques has further opened the door to a wide range of mechanotransduction studies. In recent years, new multidimensional and multiharmonic AFM approaches for mapping mechanical properties have been developed, which allow the rapid determination of, for example, cell elasticity. This Progress Report provides an introduction and practical guide to making AFM‐based nanomechanical measurements of cells and surfaces for tissue engineering applications.
Atomic force microscopy is an indispensable tool for nanomechanical measurements of cells, cell microenvironments, and biomaterials. The mechanical properties of cells and their function are influenced by the elasticity of the extracellular matrix. Thus, understanding the nanomechanical properties is key for tissue engineering applications.