Coherent elastic neutrino–nucleus scattering (CEνNS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources ...to explore this process at low energies since they deliver large fluxes of anti-neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CEνNS is described. The NUCLEUS experiment will use cryogenic detectors which feature an unprecedentedly low-energy threshold and a time response fast enough to be operated under above-ground conditions. Both sensitivity to low-energy nuclear recoils and a high event rate tolerance are stringent requirements to measuring CEνNS of reactor anti-neutrinos. A new experimental site, the Very-Near-Site (VNS), at the Chooz nuclear power plant in France is described. The VNS is located between the two 4.25 GWth reactor cores and matches the requirements of NUCLEUS. First results of on-site measurements of neutron and muon backgrounds, the expected dominant background contributions, are given. In this paper a preliminary experimental set-up with dedicated active and passive background reduction techniques and first background estimations are presented. Furthermore, the feasibility to operate the detectors in coincidence with an active muon veto at shallow overburden is studied. The paper concludes with a sensitivity study pointing out the physics potential of NUCLEUS at the Chooz nuclear power plant.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter ...space. We operated a prototype detector module based on a Formula omitted target crystal in an above-ground laboratory. Despite the high background environment, the detector sets a competitive limit on spin-dependent interactions of dark matter particles with protons and neutrons for masses between Formula omitted and Formula omitted.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Coherent elastic neutrino-nucleus scattering and low-mass dark matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear ...recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO_{4} cryogenic detector from the NUCLEUS experiment exposed to a ^{252}Cf source placed in a compact moderator. We identify the expected peak structure from the single-γ de-excitation of ^{183}W with 3σ and its origin by neutron capture with 6σ significance. This result demonstrates a new method for precise, in situ, and nonintrusive calibration of low-threshold experiments.
The NUCLEUS experiment aims for the detection of coherent elastic neutrino-nucleus scattering at a nuclear power reactor with gram-scale, ultra-low-threshold cryogenic detectors. This technology ...leads to a miniaturization of neutrino detectors and allows to probe physics beyond the Standard Model of particle physics. A 0.5 g NUCLEUS prototype detector, operated above ground in 2017, reached an energy threshold for nuclear recoils of below 20 eV. This sensitivity is achieved with tungsten transition edge sensors which are operating at temperatures of 15 mK and are mainly sensitive to non-thermal phonons. These small recoil energies become accessible for the first time with this technology, which allows collecting large-statistics neutrino event samples with a moderate detector mass. A first-phase cryogenic detector array with a total mass of 10 g enables a 5-sigma observation of coherent scattering within several weeks. We identified a suitable experimental site at the Chooz Nuclear Power Plant and performed muon and neutron background measurements there. The operation of a NUCLEUS cryogenic detector array at such a site requires highly efficient background suppression. NUCLEUS plans to use an innovative technique consisting of separate cryogenic anticoincidence detectors against surface backgrounds and penetrating (gamma, neutron) radiation. We present first results from prototypes of these veto detectors and their operation in coincidence with a NUCLEUS target detector.
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector ...that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a Transition Edge Sensor made of Tungsten (W-TES). Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c
2
. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential ...to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8 K and observed to increase by a factor of 1.61 ± 0.05 compared to 300 K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in
CaWO
4
...crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to
(
68
±
16
)
%
of the electromagnetic background in the energy range between 1 and
40
keV
.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
The development of low-threshold detectors for the study of
coherent elastic neutrino-nucleus scattering and for the search for
light dark matter necessitates methods of low-energy ...calibration. We
suggest this can be provided by the nuclear recoils resulting from
the γ emission following thermal neutron capture. In
particular, several MeV-scale single-γ transitions induce
well-defined nuclear recoil peaks in the 100 eV range. Using the
FIFRELIN code, complete schemes of γ-cascades for various
isotopes can be predicted with high accuracy to determine the
continuous background of nuclear recoils below the calibration
peaks. We present a comprehensive experimental concept for the
calibration of CaWO
4
and Ge cryogenic detectors at a research
reactor. For CaWO
4
the simulations show that two nuclear recoil
peaks at 112.5 eV and 160.3 eV should be visible above background
simply in the spectrum of the cryogenic detector. Then we discuss
how the additional tagging for the associated γ increases the
sensitivity of the method and extends its application to a wider
energy range and to Ge cryogenic detectors.
Recently low-mass dark matter direct searches have been hindered by a low-energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is ...characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed, and they are presented in this contribution.