The response of soft tissue to loading can be obtained by strain assessment. Typically, strain can be measured using electrical resistance with strain gauges (SG), or optical sensors based on the ...digital image correlation (DIC), among others. These sensor systems are already established in other areas of technology. However, sensors have a limited range of applications in medical technology due to various challenges in handling human soft materials. The aim of this study was to compare directly attached foil-type SG and 3D-DIC to determine the strain of axially loaded human ligament structures. Therefore, the medial (MCL) and lateral (LCL) collateral ligaments of 18 human knee joints underwent cyclic displacement-controlled loading at a rate of 20 mm/min in two test trials. In the first trial, strain was recorded with the 3D-DIC system and the reference strain of the testing machine. In the second trial, strain was additionally measured with a directly attached SG. The results of the strain measurement with the 3D-DIC system did not differ significantly from the reference strain in the first trial. The strains assessed in the second trial between reference and SG, as well as between reference and 3D-DIC showed significant differences. This suggests that using an optical system based on the DIC with a given unrestricted view is an effective method to measure the superficial strain of human ligaments. In contrast, directly attached SGs provide only qualitative comparable results. Therefore, their scope on human ligaments is limited to the evaluation of changes under different conditions.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
With increasing age, gait changes often occur, leading to mobility problems and thus a higher risk of falling. Interest in training at home or at retirement homes has led to the development of ..."mobile treadmills." A difference in treadmill surface length may influence walking parameters (i.e., step length) and therefore may affect muscle activation. This led to the question: Does the treadmill size affect the muscle activation, i.e., with the length of the walking surface. The study aimed to investigate the influence of treadmill size, i.e., length of the walking surface, on gait pattern and to determine differences in the amplitude of muscle activation using a participant-specific musculoskeletal model (AnyBody Technology A/S, Aalborg, Denmark). For a prospective, randomized study gait parameters were collected from 47 healthy participants (aged 50.19 ± 20.58 years) while walking on two different treadmills, a small mobile treadmill (walking surface length 100 cm) and a conventional treadmill (walking surface length 150 cm), at their preferred speed, 2 km/h, and 4 km/h. Muscle activation amplitude patterns were similar between treadmills (M. gastrocnemius medialis: r
= 0.94, M. gastrocnemius lateralis: r
= 0.92, M. gluteus medius r
= 0.90, M. gluteus minimus r
= 0.94). However, the gait analysis showed a decreased preferred velocity (
< 0.001,
= 4.54), reduced stride length (preferred velocity:
= 0.03,
= -2.17; 2 km/h:
= 0.36,
= 2.10; 4 km/h:
= 0.006,
= 2.76), shorter stride time (2 km/h:
< 0.001,
= 4.65; 4 km/h:
< 0.001,
= 4.15), and higher cadence (2 km/h:
< 0.001,
= -4.20; 4 km/h: p = 0.029,
= -2.18) on the mobile treadmill than on the conventional treadmill. Our observations suggest that the treadmill design (e.g., a 50 cm difference in walking surface length) may not influence muscle activity amplitude during walking. However, the design of the treadmill may influence gait characteristics (e.g., stride length, cadence) of walking.
Osteoporotic proximal femur fractures are on the rise due to demographic change. The most dominant surgical treatment option for per/subtrochanteric fractures is cephalomedullary nailing. As it has ...been shown to increase primary stability, cement augmentation has become increasingly popular in the treatment of osteoporotic per/subtrochanteric femur fractures. The ultimate goal is to achieve stable osteosynthesis, allowing for rapid full weight-bearing to reduce possible postoperative complications. In recent years, bioresorbable bone cements have been developed and are now mainly used to fill bone voids. The aim of this study was to evaluate the biomechanical stability as well as the micro-structural behaviour of bioresorbable bone cements compared to conventional polymethylmethacrylate (PMMA)-cements in a subtrochanteric femur fracture model. Biomechanical as well as micro-computed tomography morphology analysis revealed no significant differences in both bone cements, as they showed equal mechanical stability and tight interdigitation into the spongious bone of the femoral head. Given the positive risk/benefit ratio for bioresorbable bone cements, their utilisation should be evaluated in future clinical studies, making them a promising alternative to PMMA-bone cements.
Wear is an important factor in the long-term success of total knee arthroplasty (TKA). Therefore, wear testing methods have become standard in implant research and development. In the EU, these are ...based on two simulation concepts, which are defined in standards ISO 14243-1 and 14243-3, differentiated by the control mode—force-controlled or displacement-controlled. The aim of this study was to compare the mechanical stresses within the different ISO concepts using a finite element model (the newest displacement-controlled norm from 2014 compared with force-controlled). The in silico model showed strong correlation with the experimental data (r > 0.8). The adapted force-controlled ISO showed higher mechanical stress during the gait cycle, which also might lead to higher wear rates (14243-1 (2009): 11.15 MPa, 10.15 MPa and 9.16 MPa). The displacement-controlled ISO led to higher mechanical stress because of the constraint at the end of the stance phase (14243-3: 20.59 MPa and 17.19 MPa). Future studies should analyse different inlay designs within the same ISO standards to guarantee comparability.
Introduction
Aseptic loosening and periprosthetic fractures are main reasons for revision after THA. Quite different from most other stem systems, Corail cementless hip stems show better survival ...rates than their cemented counterpart, which can possibly be explained by the use of a collar. The study aimed to investigate primary stability with standard and undersized hip stems both collared and collarless.
Materials and methods
Primary stability of cementless, collared and collarless, femoral stems was measured in artificial bones using both undersized and standard size. After preconditioning, 3D micromotion was measured under cyclic loading at the bone-implant interface.
Results
The use of a collar resulted in higher micromotion within the same stem size but showed no statistically significant difference for both standard and undersized hip stems. The collared and collarless undersized stems showed no significant differences in 3D micromotion at the upper measuring positions compared to the standard stem size. Micromotion was significantly higher in the distal measuring positions, with and without collar, for the undersized stems (vs. standard collarless stem size).
Conclusion
The key finding is that the collarless and collared Corail hip stems, within one stem size, showed no significant differences in primary stability. Undersized stems showed significantly higher micromotion in the distal area both with and without collar.
Purpose
Due to the demographic change towards an older society, osteoporosis-related proximal femur fractures are steadily increasing. Intramedullary nail osteosyntheses are available in different ...lengths, where the field of application overlaps. The aim of this study was to investigate whether subtrochanteric fractures can also be treated stably using a short femoral intramedullary nail in cadaveric bones.
Methods
A short PFNA and a long PFNA were implanted in both seven artificial bones and osteoporotic human specimens. A standardized AO 31-A3 (reverse-oblique) fracture was placed in the specimens with a lateral fracture spur 2 cm proximal to the distal locking screw (short PFNA) and embedded. The simulated iliotibial tract was preloaded to 50 N. The force was applied at 10 mm/min up to a force of 200–800 N (artificial bones) and 200–400 N (human specimens). The dislocation of the fracture gap, the axial bone stiffness of bone construct and the force curve of the tractus iliotibialis were measured.
Results
There is no difference in the use of a short versus long PFNA in terms of stiffness of the overall construct and only a slight increase in dislocation in the fracture gap results with short PFNA compared to a long intramedullary nail.
Conclusion
In summary of the available literature, the present study supports the thesis that there is no clinical difference between long versus short nails in A3 femur fractures. Furthermore, the present study defines a safe biomechanical range of fracture extension above the locking screw of the short intramedullary nail.
Level of Evidence
III
Introduction
Open book fractures are challenging injuries oftentimes requiring surgical treatment. The current treatment of choice is symphyseal plating, which requires extensive surgery and entirely ...limits physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a semi-rigid implant (modified SpeedBridge
™
) as a minimally invasive tape suture construct for the treatment of open book fractures and evaluated the superiority of two techniques of implementation: criss-cross vs. triangle technique.
Materials and methods
Nine synthetic symphyseal joints were dissected creating an open book fracture. The different osteosynthesis methods (plating, modified SpeedBridge
™
in criss-cross/triangle technique) were then applied. All constructs underwent horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, dislocation (mm) and stiffness (N/mm) were calculated.
Results
Symphyseal plating for the treatment of open book fractures proved to be a rigid osteosynthesis significantly limiting the physiological mobility of the symphyseal joint (dislocation: 0.08 ± 0.01 mm) compared to the tape sutures (dislocation: triangle technique 0.27 ± 0.07 mm, criss-cross technique 0.23 ± 0.05 mm) regarding horizontal tension (
p
< 0.01). Both modified SpeedBridge
™
techniques showed sufficient biomechanical stability without one being superior to the other (
p
> 0.05 in all directions).
Considering vertical loading, no statistical difference was found between all osteosynthesis methods (caudal:
p
= 0.41; cranial:
p
= 0.61).
Conclusions
Symphyseal plating proved to be the osteosynthesis method with the highest rigidity. The modified SpeedBridge
™
as a semi-rigid suture construct provided statistically sufficient biomechanical stability while maintaining a minimum of symphyseal movement, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis. Furthermore, both the criss-cross and the triangle technique displayed significant biomechanical stability without one method being superior.
Introduction
Open book injuries are challenging injuries that oftentimes require surgical treatment. Currently, treatment is performed with symphyseal plating requiring extensive surgery and entirely ...limiting physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a minimally invasive tape suture construct (modified SpeedBridge™) as an alternative stabilization technique for the treatment of open book injuries in human cadaver pelvic rings.
Materials and Methods
The symphysis of 9 human cadaver pelvises was dissected and dilated to 3 cm creating an open book injury. Next, the two osteosynthesis methods (plating, modified SpeedBridge™) were applied. All specimens then underwent cyclic horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, 3D dislocation (mm) was calculated.
Results
Total displacement (mm) of the pubic symphysis displayed the following means and standard deviations: native group 1.34 ± 0.62 mm, open book group 3.01 ± 1.26 mm, tape group 1.94 ± 0.59 mm and plate group 1.37 ± 0.41 mm. Comparison between native and open book (
p
= 0.029), open book and plate (
p
= 0.004), open book and tape (
p
= 0.031), as well as tape and plate group (
p
= 0.002) showed significant differences. No significant differences were found when comparing the native and tape (
p
= 0.059), as well as the native and plate (
p
= 0.999) group.
Conclusion
While both osteosynthesis techniques sufficiently stabilized the injury, symphyseal plating displayed the highest rigidity. The modified SpeedBridge™ as a tape suture construct provided statistically sufficient biomechanical stability while maintaining symphyseal micro mobility, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis.
Varus position of cementless stems is a common malalignment in total hip arthroplasty. Clinical studies have reported a low rate of aseptic loosening but an increased risk for thigh pain. This in ...vitro study aimed to evaluate these clinical observations from a biomechanical perspective.
A conventional cementless stem (CLS Spotorno) was implanted in a regular, straight (size 13.75) as well as in a varus position (size 11.25) in 6 composite femora (Sawbones), respectively. Primary stability was assessed by recording 3-dimensional micromotions under dynamic load bearing conditions and stress shielding was evaluated by registering the surface strain before and after stem insertion.
Primary stability for stems in varus malposition revealed significantly lower micromotions (p < 0.05) for most regions compared to stems in neutral position. The greatest difference was observed at the tip of the stem where the straight aligned implants exceeded the critical upper limit for osseous integration of 150 μm. The surface strains for the varus aligned stems revealed a higher load transmission to the femur, resulting in a clearly altered strain distribution.
This biomechanical study confirms the clinical findings of a good primary stability of cementless stems in a varus malposition, but impressively demonstrates the altered load transmission with the risk for postoperative thigh pain.
•Biomechanical differences of hip stems in normal straight and varus position.•Comparison of 3-dimensional micromotions and surface strain distributions•Varus position resulted in lower micromotions.•Varus aligned stems clearly altered strain distribution.
Stem anteversion in total hip arthroplasty is well known to have a high impact on dislocation, but empirical data regarding the clinical and biomechanical influence is lacking. Therefore, we ...evaluated the impact of different anteversion alignments on the primary stability and strain distribution of a cementless stem.
The cementless CLS Spotorno stem was implanted in 3 different groups (each group n = 6, total n = 21) with different anteversion alignments: reference anteversion (8°), +15° torsion in anteversion (+23°), −15° torsion in retroversion (−7°) using composite femurs (Sawbones). Primary stability was determined by 3-dimensional micromotions using a dynamic loading procedure simulating walking on level ground. Additionally, surface strains were registered before and after stem insertion in the 3 different groups, using one composite femur for each group (total n = 3).
The micromotion measurements did not show a significant difference between the 3 evaluated alignments. Moreover, determination of the strain distribution did also not reveal an obvious difference.
This biomechanical study simulating walking on level ground indicates that there is no considerable influence of stem ante−/retroversion variation (±15°) on the initial stability and strain distribution when evaluating the cementless CLS Spotorno in composite femora.
•A conventional cementless stem was evaluated in different anteversion variations (±15°).•3-dimensional micromotions and surface strain distributions were measured.•There was no significant influence of stem anteversion on initial stability and strains.