The clumped isotopic composition of carbonate‐derived CO2 (denoted Δ47) is a function of carbonate formation temperature and in natural samples can act as a recorder of paleoclimate, burial, or ...diagenetic conditions. The absolute abundance of heavy isotopes in the universal standards VPDB and VSMOW (defined by four parameters: R13VPDB, R17VSMOW, R18VSMOW, and λ) impact calculated Δ47 values. Here, we investigate whether use of updated and more accurate values for these parameters can remove observed interlaboratory differences in the measured T‐Δ47 relationship. Using the updated parameters, we reprocess 14 published calibration data sets measured in 11 different laboratories, representing many mineralogies, bulk compositions, sample types, reaction temperatures, and sample preparation and analysis methods. Exploiting this large composite data set (n = 1,253 sample replicates), we investigate the possibility for a “universal” clumped isotope calibration. We find that applying updated parameters improves the T‐Δ47 relationship (reduces residuals) within most labs and improves overall agreement but does not eliminate all interlaboratory differences. We reaffirm earlier findings that different mineralogies do not require different calibration equations and that cleaning procedures, method of pressure baseline correction, and mass spectrometer type do not affect interlaboratory agreement. We also present new estimates of the temperature dependence of the acid digestion fractionation for Δ47 (Δ*25‐X), based on combining reprocessed data from four studies, and new theoretical equilibrium values to be used in calculation of the empirical transfer function. Overall, we have ruled out a number of possible causes of interlaboratory disagreement in the T‐Δ47 relationship, but many more remain to be investigated.
Plain Language Summary
Measured stable and clumped isotope values are fundamentally tied to established compositions of international standard materials. When these standard compositions are updated, it impacts previously published isotope measurements such as those used to define the clumped isotope calibration relationship (the foundation for use of this isotopic proxy as a paleothermometer, recorder of burial history or past diagenetic conditions). Here we reprocess 14 published clumped isotope calibration studies using updated international standard compositions and identical data processing procedures to see if these changes would eliminate previously observed interlaboratory discrepancies in clumped isotope calibration relationships. We find that this update tightens the clumped isotope calibration relationship within most laboratories and improves overall agreement between laboratories but does not eliminate all interlaboratory differences. We also propose “best practices” for data processing and dissemination going forward. This study makes progress toward resolving discrepancies in clumped isotope calibration relationships between laboratories by eliminating a number of possible causes and moves the clumped isotope community closer toward our ultimate goal of applying this powerful new proxy routinely to exciting science questions.
Key Points
Updates to 17O correction parameters and international standard compositions affect clumped isotopic compositions
Reprocessing published calibration data using new parameters and consistent methodology slightly improves interlaboratory agreement
There is no evidence (within error) for mineral‐specific offsets in calibration equation or temperature dependence of acid digestion fractionation
The potential for carbonate clumped isotope thermometry to independently constrain both the formation temperature of carbonate minerals and fluid oxygen isotope composition allows insight into ...long‐standing questions in the Earth sciences, but remaining discrepancies between calibration schemes hamper interpretation of temperature measurements. To address discrepancies between calibrations, we designed and analyzed a sample suite (41 total samples) with broad applicability across the geosciences, with an exceptionally wide range of formation temperatures, precipitation methods, and mineralogies. We see no statistically significant offset between sample types, although the comparison of calcite and dolomite remains inconclusive. When data are reduced identically, the regression defined by this study is nearly identical to that defined by four previous calibration studies that used carbonate‐based standardization; we combine these data to present a composite carbonate‐standardized regression equation. Agreement across a wide range of temperature and sample types demonstrates a unified, broadly applicable clumped isotope thermometer calibration.
Plain Language Summary
Carbonate clumped isotope thermometry is a geochemical tool used to determine the formation temperature of carbonate minerals. In contrast to previous carbonate thermometers, clumped isotope thermometry requires no assumptions about the isotopic composition of the fluid from which the carbonate precipitated. By measuring the clumped isotope composition (Δ47) of carbonate minerals with a known formation temperature, we can construct an empirical calibration for the clumped isotope thermometer that is necessary to convert from a Δ47 value to formation temperature. Many previous studies have created Δ47 temperature calibrations, but differences between calibrations have led to large uncertainty in final Δ47 temperatures. This study measures a large number of samples that span a wide range of temperatures (0.5–1,100°C) and include many different types of carbonates. These data show that a single calibration equation can describe many sample types and that when data are carefully standardized to a common set of carbonate materials, calibrations performed at different laboratories agree almost identically. We combine these data to present a carbonate clumped isotope thermometer calibration with broad applicability across the geosciences.
Key Points
Reanalysis of previous Δ47 calibration samples reconciles their discrepancies
No statistically significant difference is observed across a wide range of temperature and sample character
This Δ47 calibration is near‐identical to recent calcite calibrations using carbonate‐based standardization
We report experimental evidence that multi-MeV protons accelerated in relativistic laser-plasma interactions are modulated by strong filamentary electromagnetic fields. Modulations are observed when ...a preplasma is developed on the rear side of a μm-scale solid-density hydrogen target. Under such conditions, electromagnetic fields are amplified by the relativistic electron Weibel instability and are maximized at the critical density region of the target. The analysis of the spatial profile of the protons indicates the generation of B>10 MG and E>0.1 MV/μm fields with a μm-scale wavelength. These results are in good agreement with three-dimensional particle-in-cell simulations and analytical estimates, which further confirm that this process is dominant for different target materials provided that a preplasma is formed on the rear side with scale length ≳0.13λ_{0}sqrta_{0}. These findings impose important constraints on the preplasma levels required for high-quality proton acceleration for multipurpose applications.
We consider the scattering of an x-ray free-electron laser (XFEL) beam on the superposition of a strong magnetic field Bext with the Coulomb field E ext of a nucleus with charge number Z . In ...contrast to Delbrück scattering (Coulomb field only), the magnetic field Bext introduces an asymmetry (i.e., polarization dependence) and renders the effective interaction volume quite large, while the nuclear Coulomb field facilitates a significant momentum transfer Δk. For a field strength of Bext = 106 T (corresponding to an intensity of order 1022 W / cm2) and an XFEL frequency of 24 keV, we find a differential cross section dσ/dΩ ∼10−25 Z2 / (Δk)2 in forward direction for one nucleus. Thus, this effect might be observable in the near future at facilities such as the Helmholtz International Beamline for Extreme Fields at the European XFEL.
We present an experimental study investigating laser-driven proton acceleration via target normal sheath acceleration (TNSA) over a target thickness range spanning the typical TNSA-dominant regime ...(∼1 m) down to below the onset of relativistic laser-transparency (<40 nm). This is done with a single target material in the form of freely adjustable films of liquid crystals along with high contrast (via plasma mirror) laser interaction (∼2.65 J, 30 fs, I > 1 × 10 21 W cm−2). Thickness dependent maximum proton energies scale well with TNSA models down to the thinnest targets, while those under ∼40 nm indicate the influence of relativistic transparency on TNSA, observed via differences in light transmission, maximum proton energy, and proton beam spatial profile. Oblique laser incidence (45°) allowed the fielding of numerous diagnostics to determine the interaction quality and details: ion energy and spatial distribution was measured along the laser axis and both front and rear target normal directions; these along with reflected and transmitted light measurements on-shot verify TNSA as dominant during high contrast interaction, even for ultra-thin targets. Additionally, 3D particle-in-cell simulations qualitatively support the experimental observations of target-normal-directed proton acceleration from ultra-thin films.
We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse ...parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.
Often, the interpretation of experiments concerning the manipulation of the energy distribution of laser-accelerated ion bunches is complicated by the multitude of competing dynamic processes ...simultaneously contributing to recorded ion signals. Here we demonstrate experimentally the acceleration of a clean proton bunch. This was achieved with a microscopic and three-dimensionally confined near critical density plasma, which evolves from a 1 µm diameter plastic sphere, which is levitated and positioned with micrometer precision in the focus of a Petawatt laser pulse. The emitted proton bunch is reproducibly observed with central energies between 20 and 40 MeV and narrow energy spread (down to 25%) showing almost no low-energetic background. Together with three-dimensional particle-in-cell simulations we track the complete acceleration process, evidencing the transition from organized acceleration to Coulomb repulsion. This reveals limitations of current high power lasers and viable paths to optimize laser-driven ion sources.
Abstract
We present a computational study of isochoric heating in multi-layered (ML) targets at ultra-high intensity laser irradiation (
∼
10
20
W
c
m
−
2
). Previous studies have shown enhanced ion ...heating at interfaces, but at the cost of large temperature gradients. Here, we study ML targets to spread this enhanced interface heating to the entirety of the target and find heating parameters at which the temperature distribution is more homogeneous than at a single interface while still exceeding the mean temperature of a non-layered target. Further, we identify a limiting process of pressure oscillations that causes the layers to alternate between expanding and being compressed and leads to lower ion temperatures. Based on that, we derive an analytical model estimating the oscillation period to find target conditions that optimize heating and temperature homogeneity. This model can also be used to infer the electron energy from the oscillation period which can be measured e.g. by XFEL probing.
A precise knowledge of the temperature and number of hot electrons generated in the interaction of short-pulse high-intensity lasers with solids is crucial for harnessing the energy of a laser pulse ...in applications such as laser-driven ion acceleration or fast ignition. Nevertheless, present scaling laws tend to overestimate the hot electron temperature when compared to experiment and simulations. We present a novel approach that is based on a weighted average of the kinetic energy of an ensemble of electrons. We find that the scaling of electron energy with laser intensity can be derived from a general Lorentz invariant electron distribution ansatz that does not rely on a specific model of energy absorption. The scaling derived is in perfect agreement with simulation results and clearly follows the trend seen in recent experiments, especially at high laser intensities where other scalings fail to describe the simulations accurately.