The high luminosity upgrade of the Large Hadron Collider, foreseen for 2027, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected total ...integrated luminosity of 4000 fb−1 means that the strip part of the ITk detector will be exposed to a large radiation fluence of up to Φeq = 1.6 × 1015 1 MeV neq/cm and an ionizing dose of 0.66 MGy, including a safety factor of 1.5. Radiation-hard n+-in-p micro-strip sensors for use in the ITk have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics K.K. In this paper, the results obtained from the electrical characterization of the latest barrel ATLAS17LS sensor prototype, before and after irradiation, are shown.
Surface properties of the long-strip barrel, full-sized and miniature sensors have been studied before and after proton, neutron and gamma irradiation up to the maximal fluences and radiation doses specified for the ITk Strip tracker. Sensors have been irradiated by protons at CYRIC, Tohoku University (Japan), the Proton Irradiation Facility at CERN, Karlsruhe Inst. Tech. (Germany) and at the University of Birmingham (UK), by neutrons from the Ljubljana TRIGA reactor (Slovenia) and by gamma rays from the 60Co source in UJP Praha (Czech Republic).
It has been verified that the surface radiation damage does not influence the sensor functionality. The breakdown voltage is well above the maximum operational voltage. All the tested surface parameters, such as the inter-strip resistance and capacitance, coupling capacitance and bias resistance satisfy the ATLAS ITk specifications for strip sensors.
We present the first measurements of absolute branching fractions of Ξ_{c}^{0} decays into Ξ^{-}π^{+}, ΛK^{-}π^{+}, and pK^{-}K^{-}π^{+} final states. The measurements are made using a dataset ...comprising (772±11)×10^{6} BBover ¯ pairs collected at the ϒ(4S) resonance with the Belle detector at the KEKB e^{+}e^{-} collider. We first measure the absolute branching fraction for B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0} using a missing-mass technique; the result is B(B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0})=(9.51±2.10±0.88)×10^{-4}. We subsequently measure the product branching fractions B(B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→Ξ^{-}π^{+}), B(B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→ΛK^{-}π^{+}), and B(B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→pK^{-}K^{-}π^{+}) with improved precision. Dividing these product branching fractions by the result for B^{-}→Λover ¯_{c}^{-}Ξ_{c}^{0} yields the following branching fractions: B(Ξ_{c}^{0}→Ξ^{-}π^{+})=(1.80±0.50±0.14)%, B(Ξ_{c}^{0}→ΛK^{-}π^{+})=(1.17±0.37±0.09)%, and B(Ξ_{c}^{0}→pK^{-}K^{-}π^{+})=(0.58±0.23±0.05)%. For the above branching fractions, the first uncertainties are statistical and the second are systematic. Our result for B(Ξ_{c}^{0}→Ξ^{-}π^{+}) can be combined with Ξ_{c}^{0} branching fractions measured relative to Ξ_{c}^{0}→Ξ^{-}π^{+} to yield other absolute Ξ_{c}^{0} branching fractions.
This paper presents a search for the rare flavor-changing neutral current process B0 → K*0τ+τ- using data taken with the Belle detector at the KEKB asymmetric energy e+e- collider. The analysis is ...based on the entire ϒ ( 4S ) resonance data sample of 711 fb-1 , corresponding to 772×106B B ¯ pairs. In our search we fully reconstruct the companion B meson produced in the process e+e- → ϒ ( 4S ) → B B ¯ from its hadronic decay modes, and look for the decay B0 → K*0τ+τ- in the rest of the event. No evidence for a signal is found. We report an upper limit on the branching fraction B ( B0 → K*0τ+τ- ) <3.1×10-3 at 90% confidence level. This is the first direct limit on B ( B0 → K*0τ+τ- ) .
Abstract
The Silicon Vertex Detector of Belle II is a
state-of-the-art tracking and vertexing system based on double-sided
silicon strip sensors, designed and fabricated by a large
international ...collaboration in the period 2012–2018. Since 2019 it
has been in operation providing high quality data with a small
number of defective channels (<1%), a large hit-finding
efficiency (>99%), a good signal-to-noise ratio (well in excess
of 10 for all sensor configurations and tracks). Together with the
good control over the alignment, these are all essential factors to
achieve good tracking reconstruction and physics performance. In
this extended paper we try to document all the aspects of the SVD
challenges and achievements, in the spirit of providing information
to the broader community and help the development of high quality
detector systems, which are essential tools to carry out physics
research.
We report the first observation of the double strange baryon Ξ(1620)^{0} in its decay to Ξ^{-}π^{+} via Ξ_{c}^{+}→Ξ^{-}π^{+}π^{+} decays based on a 980 fb^{-1} data sample collected with the Belle ...detector at the KEKB asymmetric-energy e^{+}e^{-} collider. The mass and width are measured to be 1610.4±6.0(stat)_{-4.2}^{+6.1} (syst) MeV/c^{2} and 59.9±4.8(stat)_{-7.1}^{+2.8}(syst) MeV, respectively. We obtain 4.0σ evidence of the Ξ(1690)^{0} with the same data sample. These results shed light on the structure of hyperon resonances with strangeness S=-2.
Miniature sensors with external dimensions of 10 mm x 10 mm were produced together with full-size sensors for the innermost ring (R0) of the end-cap part in the upgraded ATLAS inner tracker (ITk). ...AC- and DC-coupled n-type strips with three different pitches (wide, default and narrow) were processed on high-resistivity p-type FZ silicon substrates by Hamamatsu Photonics. The miniature sensors were irradiated with 70-MeV protons at CYRIC, Tohoku University (Japan) and reactor neutrons at the Jožef Stefan Institute (Slovenia) to three different 1-MeV neutron equivalent fluences: 0.5, 1 and 2 x 1015neqcm−2. The upper fluence range exceeds the highest anticipated in the innermost part of the ATLAS ITk-Strips over the HL-LHC lifetime (∼1.25 × 1015neqcm2). The charge collection in the test sensors was evaluated systematically using a 90Sr β-source and an Alibava analogue readout system at reverse-bias voltages up to 1000 V.
•The charge collection in the test sensors was evaluated systematically.•The collected charge increases with the applied voltage.•At higher voltages the effect of multiplication can be seen.•The multiplication becomes higher at long annealing times.
The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, a DEPFET-technology based silicon detector with pixel readout. A ...large fraction of the background hits can be rejected by defining a set of regions of interest (ROIs) on the pixel detector sensors (PXD) and then recording just the data from the pixels inside the ROI. The ROIs are defined on an event by event basis by extrapolating back onto the PXD the charged tracks detected in the outer trackers (a four-layer double-sided silicon strip detector surrounded by a wire chamber). The tracks are reconstructed in real time on the High Level Trigger (HLT). The pixel detector is then read out based on the ROI information. A demonstrator of this architecture was under beam test earlier this year in DESY (Hamburg, Germany). The demonstrator was operated in an electron beam whose momentum was in the 2-6 GeV/c range with a typical trigger rate of a few kilohertz in a magnetic field of strength up to 1 T. The demonstrator consists of one pixel sensor and four silicon strip sensors arranged in a five-layer configuration mimicking the Belle II vertex detector. The detector readout was a scaled down version of the full Belle II DAQ + HLT chain. The demonstrator was used to detect the particles, reconstruct in real time the trajectories, identify the ROIs on the PXD plane and record the PXD data within. We describe the requirements and the architecture of the final system together with the results obtained with the demonstrator.
We report measurements of B→χ(c1)γK and χ(c2)γK decays using 772×10(6) BBover ¯ events collected at the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e(+)e(-) collider. ...Evidence of a new resonance in the χ(c1)γ final state is found with a statistical significance of 3.8σ. This state has a mass of 3823.1±1.8(stat)±0.7(syst) MeV/c(2), a value that is consistent with theoretical expectations for the previously unseen 1(3)D(2) ccover ¯ meson. We find no other narrow resonance and set upper limits on the branching fractions of the X(3872)→χ(c1)γ and χ(c2)γ decays.
A radiation hard n+-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the ...“ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics.
Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punch-through protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×1016 neq/cm2, by reactor neutron fluence of 1×1015 neq/cm2 and by gamma rays from 60Co up to dose of 1MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07.
•Surface study verified high radiation resistance of developed n-in-p strip sensors.•Sensors have high breakdown voltage before and after irradiation.•Inter-strip capacitance is sufficiently low and does not change with irradiation.•Primary factor of inter-strip resistance decrease is total ionizing dose.•New gated PTP doubles current flowing into bias rail without onset voltage increase.
We report the first evidence for the η(b)(2S) using the h(b)(2P)→η(b)(2S)γ transition and the first observation of the h(b)(1P)→η(b)(1S)γ and h(b)(2P)→η(b)(1S)γ transitions. The mass and width of the ...η(b)(1S) and η(b)(2S) are measured to be m(η(b)(1S))=(9402.4±1.5±1.8) MeV/c(2), m(η(b)(2S))=(9999.0±3.5(-1.9)(+2.8)) MeV/c(2), and Γ(η(b)(1S))=(10.8(-3.7-2.0)(+4.0+4.5)) MeV. We also update the h(b)(1P) and h(b)(2P) mass measurements. We use a 133.4 fb(-1) data sample collected at energies near the Υ(5S) resonance with the Belle detector at the KEKB asymmetric-energy e(+)e(-) collider.