Endothelin-1 (ET-1) undergoes an about 8-h (circaoctohoran) rather than a circadian variation in clinical health. Herein, 24
h plasma concentrations of vasoactive intestinal peptide (VIP), substance ...P (SP), neuropeptide Y (NpY), and cortisol used as reference, were obtained from 20 healthy young adults starting at 07:00 or 19:00
h. Like ET-1, SP and NpY undergo a circaoctohoran variation, whereas VIP is circadian rhythmic, peaking during the night, some 8
h prior to the circadian acrophase of cortisol. Maps of circadian and extra-circadian patterns may serve for screening, diagnosis and a better understanding of mechanisms underlying the etiology of various diseases.
New results on silicon microstrip detectors of CMS tracker Demaria, N.; Albergo, S.; Angarano, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2000, Letnik:
447, Številka:
1
Journal Article
Recenzirano
Interstrip and backplane capacitances on silicon microstrip detectors with p
+ strip on n substrate of
320
μm
thickness were measured for pitches between 60 and
240
μm
and width over pitch ratios ...between 0.13 and 0.5. Parametrisations of capacitance w.r.t. pitch and width were compared with data. The detectors were measured before and after being irradiated to a fluence of
4×10
14
protons/
cm
2
of
24
GeV/c
momentum. The effect of the crystal orientation of the silicon has been found to have a relevant influence on the surface radiation damage, favouring the choice of a
〈1
0
0〉
substrate. Working at high bias (up to 500 V in CMS) might be critical for the stability of detector, for a small width over pitch ratio. The influence of having a metal strip larger than the p
+ implant has been studied and found to enhance the stability.
The data of 16 children who died while receiving valproate (VPA) therapy in West Germany were analyzed. Five were normally developed, 5 were receiving VPA-monotherapy, and only 2 patients were aged ...less than 3 years. The first clinical symptoms of impending hepatotoxicity usually included nausea, vomiting, and apathy; pathologic laboratory tests reflected liver failure. Liver histology revealed microvesicular steatosis, cell necrosis, and bile duct proliferation of varying degree. An abnormal metabolite, 4-ene-VPA, was detected in all examined patients (six of six) and persisted after drug withdrawal. The pathogenesis of fatal liver failure during VPA treatment remains unknown. World-wide, approximately 100 fatalities have been reported in relation to VPA treatment. More than 90% were aged less than 20 years, 95% developed their first symptoms within the first 6 months of treatment, and 16 were treated with VPA alone. Since it is difficult precisely to define a group at risk for fatalities with VPA, careful clinical and laboratory monitoring with a special focus on vomiting and apathy, liver enzymes, and coagulation tests seem mandatory during the first 6 months after introduction of VPA. Taking into account the considerable number of fatalities during VPA treatment, the indication for its use requires careful reevaluation.
We present results obtained with full-size wedge silicon microstrip detectors bonded to APV6 (Raymond et al., Proceedings of the 3rd Workshop on Electronics for LHC Experiments, CERN/LHCC/97-60) ...readout chips. We used two identical modules, each consisting of two crystals bonded together. One module was irradiated with
1.7×10
14
neutrons/cm
2
. The detectors have been characterized both in the laboratory and by exposing them to a beam of minimum ionizing particles. The results obtained are a good starting point for the evaluation of the performance of the “ensemble” detector plus readout chip in a version very similar to the final production one. We detected the signal from minimum ionizing particles with a signal-to-noise ratio ranging from 9.3 for the irradiated detector up to 20.5 for the non-irradiated detector, provided the parameters of the readout chips are carefully tuned.
Optimization of the silicon sensors for the CMS tracker Albergo, S.; Angarano, M.; Azzi, P. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2001, Letnik:
466, Številka:
2
Journal Article
Recenzirano
The CMS experiment at the LHC will comprise a large silicon strip tracker. This article highlights some of the results obtained in the R&D studies for the optimization of its silicon sensors. ...Measurements of the capacitances and of the high voltage stability of the devices are presented before and after irradiation to the dose expected after the full lifetime of the tracker.
CMS silicon tracker developments Civinini, C; Albergo, S; Angarano, M ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2002, Letnik:
477, Številka:
1
Journal Article
Recenzirano
The CMS Silicon tracker consists of
70
m
2
of microstrip sensors which design will be finalized at the end of 1999 on the basis of systematic studies of device characteristics as function of the most ...important parameters. A fundamental constraint comes from the fact that the detector has to be operated in a very hostile radiation environment with full efficiency. We present an overview of the current results and prospects for converging on a final set of parameters for the silicon tracker sensors.
The CMS silicon tracker Focardi, E; Albergo, S; Angarano, M ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2000, Letnik:
453, Številka:
1
Journal Article
Recenzirano
This paper describes the Silicon microstrip Tracker of the CMS experiment at LHC. It consists of a barrel part with 5 layers and two endcaps with 10 disks each. About 10
000 single-sided equivalent ...modules have to be built, each one carrying two daisy-chained silicon detectors and their front-end electronics. Back-to-back modules are used to read-out the radial coordinate. The tracker will be operated in an environment kept at a temperature of
T=−10°C to minimize the Si sensors radiation damage. Heavily irradiated detectors will be safely operated due to the high-voltage capability of the sensors. Full-size mechanical prototypes have been built to check the system aspects before starting the construction.
The R&D program for silicon detectors in CMS Tonelli, G; Albergo, S; Angarano, M ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/1999, Letnik:
435, Številka:
1
Journal Article
Recenzirano
This paper describes the main achievements in the development of radiation resistant silicon detectors to be used in the CMS tracker. After a general description of the basic requirements for the ...operation of large semiconductor systems in the LHC environment, the issue of radiation resistance is discussed in detail. Advantages and disadvantages of the different technological options are presented for comparison. Laboratory measurements and test beam data are used to check the performance of several series of prototypes fabricated by different companies. The expected performance of the final detector modules are presented together with preliminary test beam results on system prototypes.
The CMS silicon strip tracker Focardi, E; Albergo, S; Angarano, M ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/1999, Letnik:
435, Številka:
1
Journal Article
Recenzirano
The Silicon Strip Tracker (SST) is the intermediate part of the CMS Central Tracker System. SST is based on microstrip silicon devices and in combination with pixel detectors and the Microstrip Gas ...Chambers aims at performing pattern recognition, track reconstruction and momentum measurements for all tracks with
p
T≥2 GeV/
c originating from high luminosity interactions at
s
=14
TeV at LHC. We aim at exploiting the advantages and the physics potential of the precise tracking performance provided by the microstrip silicon detectors on a large scale apparatus and in a much more difficult environment than ever. In this paper we describe the actual SST layout and the readout system.
We report selected results of laboratory measurements and beam tests of heavily irradiated microstrip silicon detectors. The detectors were single-sided devices, produced by different manufacturers ...and irradiated with different sources, for several total ionizing doses and fluences up to 4 /spl times/10/sup 14/ 1-MeV-equivalent neutrons per cm/sup 2/. Strip resistance and capacitance, detector leakage currents and breakdown performance were measured before and after irradiations. Signal-to-noise ratio and detector efficiency were studied in beam tests, for different values of the detector temperature and of the read-out pitch, as a function of the detector bias voltage. The goal of these test is to optimise the design of the final prototypes for the Silicon Strip Tracker of the CMS experiment at the CERN LHC collider.