We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek ...to dissolve light target nuclei in the active volume of liquid-xenon time projection chambers. Low-energy helium recoils were produced by degrading α particles from ^{210}Po with a gold foil situated on the cathode of a liquid xenon time-projection chamber. The resulting population of helium recoil events is well separated from electron recoils and is also offset from the expected position of xenon nuclear recoil events.
Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation ...wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Sepsis is a heterogeneous syndrome and phenotypes have been proposed using clinical data. Less is known about the contribution of protein biomarkers to clinical sepsis phenotypes and their importance ...for treatment effects in randomized trials of resuscitation. The objective is to use both clinical and biomarker data in the Protocol-Based Care for Early Septic Shock (ProCESS) randomized trial to determine sepsis phenotypes and to test for heterogeneity of treatment effect by phenotype comparing usual care to protocolized early, goal-directed therapy(EGDT). In this secondary analysis of a subset of patients with biomarker sampling in the ProCESS trial (n = 543), we identified sepsis phenotypes prior to randomization using latent class analysis of 20 clinical and biomarker variables. Logistic regression was used to test for interaction between phenotype and treatment arm for 60-day inpatient mortality. Among 543 patients with severe sepsis or septic shock in the ProCESS trial, a 2-class model best fit the data (p = 0.01). Phenotype 1 (n = 66, 12%) had increased IL-6, ICAM, and total bilirubin and decreased platelets compared to phenotype 2 (n = 477, 88%, p < 0.01 for all). Phenotype 1 had greater 60-day inpatient mortality compared to Phenotype 2 (41% vs 16%; p < 0.01). Treatment with EGDT was associated with worse 60-day inpatient mortality compared to usual care (58% vs. 23%) in Phenotype 1 only (p-value for interaction = 0.05). The 60-day inpatient mortality was similar comparing EGDT to usual care in Phenotype 2 (16% vs. 17%). We identified 2 sepsis phenotypes using latent class analysis of clinical and protein biomarker data at randomization in the ProCESS trial. Phenotype 1 had increased inflammation, organ dysfunction and worse clinical outcomes compared to phenotype 2. Response to EGDT versus usual care differed by phenotype.
Abstract
We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon ...decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.
We discuss a novel paradigm in the optical readout of scintillation radiation detectors. In one common configuration, such detectors are homogeneous and the scintillation light is collected and ...recorded by external photodetectors. It is usually assumed that imaging in such a photon-starved and large-emittance regime is not possible. Here we show that the appropriate optics, matched with highly segmented photodetector coverage and dedicated reconstruction software, can be used to produce images of the radiation-induced events. In particular, such a “distributed imaging” system can discriminate between events produced as a single cluster and those resulting from more delocalized energy depositions. This is crucial in discriminating many common backgrounds at MeV energies. With the use of simulation, we demonstrate the performance of a detector augmented with a practical, if preliminary, set of optics. Finally, we remark that this new technique lends itself to be adapted to different detector sizes and briefly discuss the implications for a number of common applications in science and technology.
As part of the global response to the HIV/AIDS epidemic, the U.S. President's Emergency Plan for AIDS Relief (PEPFAR) is committed to the provision of high‐quality services and ensuring testing ...accuracy. Two recently published papers focusing on HIV testing and misdiagnosis in sub‐Saharan Africa by Kosack et al. report on evaluations of HIV rapid diagnostic tests (RDTs) and found lower than expected specificity and sensitivity on some tests when used in certain geographic locations. The magnitude of PEPFAR's global HIV response has been possible due to the extensive use of RDTs, which have made HIV diagnosis accessible all over the world. We take the opportunity to address concerns raised about the potential implications that these findings could have on real‐world HIV testing accuracy. PEPFAR supported countries adhere to the normative guidance by World Health Organization (WHO) supporting algorithms which require sequential positive tests for diagnostic accuracy. An analysis of Médecins Sans Frontières (MSF) RDT site‐specific data applied to PEPFAR in‐country protocols demonstrate a variation in the diagnostic accuracy of the testing algorithms, but with a very small population‐level effect. The data demonstrate, with the use of these algorithms, that the RDT outcomes found in the study by Kosack et al. would be largely mitigated and would not be expected to have a significant impact on diagnostic accuracy and overall programming in most countries. Avoiding any misdiagnosis is a priority for PEPFAR, and it remains vital to gain a deeper understanding of the causes and the extent of diagnostic errors and any misclassification. Extensive quality control mechanisms and continued research are essential. With a focus on epidemic control and ensuring diagnostic accuracy, PEPFAR recommends that all countries use WHO pre‐qualified RDTs within the recommended strategies and algorithms for HIV testing. We also support validation of HIV testing algorithms using in‐country specimens to determine optimal performance, and the reverification testing of all people diagnosed with HIV prior to starting treatment as an essential quality assurance measure.
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are ...needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrodes with areas up to 33 cm2 were tested while varying the cathode-anode separation from 1 to 6 mm with a voltage difference up to 75 kV. A power-law relationship between breakdown field and electrode area was observed. The breakdown behavior of liquid argon and liquid xenon within the same experimental apparatus was comparable.
Abstract
We present measurements of the angular distribution of
re-emitted light from tetraphenyl butadiene thin films when exposed
to 128 nm light, which is the peak of the liquid Argon (LAr)
...scintillation spectrum, in vacuum. Films ranging from 250 nm to
5.5 μm in thickness are measured. All films were fabricated
by evaporation deposition on ultraviolet transmitting (UVT) acrylic
substrates. Preliminary comparisons of the angular distribution to
that produced by a detailed Monte Carlo model are also
presented. The current shortcomings of the model are discussed and
future plans briefly outlined.