The PERCIVAL detector: first user experiments Correa, J.; Mehrjoo, M.; Battistelli, R. ...
Journal of synchrotron radiation,
January 2023, 2023-Jan-01, 2023-01-01, 20230101, 2023, Letnik:
30, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The PERCIVAL detector is a CMOS imager designed for the soft X‐ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ...ptychography at a free‐electron laser, holographic imaging at a storage ring and preliminary tests on X‐ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X‐ray science.
PERCIVAL is a detector system specifically designed for the soft X‐ray regime. Although still in a development phase, it has already served its first user experiments at both a storage ring and also a free‐electron laser. The device performed remarkably well in all the different techniques tested: ptychography, holography and also X‐ray photon correlation spectroscopy. The results of these tests are presented.
The peak brilliance reached by today's Free-Electron Laser and Synchrotron light sources requires photon detectors matching their output intensity and other characteristics in order to fully realize ...the sources' potential. The Pixellated Energy Resolving CMOS Imager, Versatile And Large (Percival) is a dedicated soft X-ray imager (0.25–1 keV) developed for this purpose by a collaboration of DESY, Rutherford Appleton Laboratory/STFC, Elettra Sincrotrone Trieste, Diamond Light Source, and Pohang Accelerator Laboratory. Following several generations of prototypes, the Percival “P2M” 2-Megapixel imager—a 4.5×5 cm monolithic, stitched sensor with an uninterrupted imaging area of 4×4 cm2 (1408×1484 pixels of 27×27 μm—was produced and has demonstrated basic functionality with a first-light image using visible light. It is currently being brought to full operation in a front-illuminated configuration. The readout system being commissioned in parallel has been developed specifically for this imager which will produce—at full 300 Hz frame rate—data at 20 Gbit/s. A first wafer with eight Percival P2M chips has undergone backthinning to enable soft X-ray detection. It has been diced and chips are currently being wirebonded. We summarize here the P2M system, the project status, and show the P2M sensor's first response to visible light.
This case report was submitted to the American Board of Orthodontics as part of the board-certification process. The summary of treatment and records are reprinted here much as they were submitted to ...the board.
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60GeV/c. ...Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of 1×1cm2 and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010–11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
A detailed investigation of hadronic interactions is performed using π−-mesons with energies in the range 2–10 GeV incident on a high granularity silicon–tungsten electromagnetic calorimeter. The ...data were recorded at FNAL in 2008. The region in which the π−-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X0 depth and 180×180mm2 transverse ...dimensions was constructed, consisting of 2160 individually read out 10×45×3mm3 scintillator strips. This prototype was tested using electrons of 2–32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12.5±0.1(stat.)±0.4(syst.))%∕EGeV⊕(1.2±0.1(stat.)−0.7+0.6(syst.))%, where the uncertainties correspond to statistical and systematic sources, respectively.
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the ...CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within + or - 5%) and a good energy resolution are obtained for a large range of hadronic energies (5-80 GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30 GeV.
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity ...scintillator-silicon photomultiplier calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the average energy response, resolution, and longitudinal shower profiles. Two techniques are applied to reconstruct the initial particle energy from the measured energy depositions; a standard energy reconstruction which is linear in the measured depositions and a software compensation technique based on reweighting individually measured depositions according to their hit energy. The results are compared to predictions of the GEANT 4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
The high granularity of the CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) provides the capability to reveal the track segments present in hadronic showers. These segments are then used as a tool ...to probe the behaviour of the active layers in situ, to better reconstruct the energy of these hadronic showers and also to distinguish them from electromagnetic ones. In addition, the comparison of these track segments in data and the simulation helps to discriminate among the different shower models used in the simulation. To extract the track segments in the showers recorded in the SDHCAL, a Hough Transform is used after being adapted to the presence of the dense core of the hadronic showers and the SDHCAL active medium structure.
High brilliance synchrotrons and FELs require high performing detector systems to realise their full potential. High dynamic range, low noise and high frame rate are all of great importance. In this ...paper we present first optical characterization results of the P2M CMOS sensor, designed for soft X-ray detection at such facilities. Previous work is summarised and an overview of the sensor is presented. Test results for the sensor's column-parallel ADC and readout chain are presented, and first test results for the pixel acquired using the Photon Transfer Curve (PTC) method are shown. Finally, an outline of future work is provided.