In Japan, with the increasing prevalence of gastroesophageal reflux disease (GERD) and growing public interest, the Japanese Society of Gastroenterology issued Evidence-based Clinical Practice ...Guidelines for GERD (1st edition) in 2009 and a revised 2nd edition in 2015. A number of studies on GERD were subsequently conducted in Japan and abroad, and vonoprazan, a potassium-competitive acid blocker (P-CAB), became available for the first time in Japan in February 2015. The revised 3rd edition (Japanese edition), which incorporates new findings and information, was published in April 2021. These guidelines are summarized herein, particularly sections related to the treatment of GERD. The important clinical issues addressed in the present revision are (i) the introduction of treatment algorithms that classify GERD into reflux esophagitis and non-erosive reflux disease, (ii) the clarification of treatment algorithms based on to the severity of reflux esophagitis, and (iii) the positioning of vonoprazan in the treatment for GERD. The present guidelines propose vonoprazan as the initial/maintenance treatment for severe reflux esophagitis. They also recommend vonoprazan or PPI as an initial treatment for mild reflux esophagitis and recommended PPI and proposed vonoprazan as maintenance treatment. These updated guidelines offer the best clinical strategies for GERD patients in Japan and hope that they will be of global use for the diagnosis and treatment for GERD.
Background
A new automated diagnostic program for high-resolution esophageal manometry (HREM) has been developed. This diagnostic program could detect locations of landmarks and could make final ...diagnoses automatically. However, the accuracy of the program is not known. The aim of this study was to evaluate the accuracy of the automated diagnostic program for HREM.
Methods
A total of 445 studies were enrolled. An HREM system (Starlet®) was used, and esophageal motility was diagnosed using the Chicago classification v3.0. First, the locations of the upper esophageal sphincter, transition zone, lower esophageal sphincter, esophago-gastric junction, crural diaphragm and stomach were determined, and each swallow was checked manually. Then, the parameters of the Chicago classification were calculated using an analytic program of the Starlet, and diagnoses were made by three experts. Second, all study raw data were analyzed again by the automated diagnostic program. Diagnoses made by the program were compared to those made by experts to evaluate the accuracy of the diagnoses.
Results
The new diagnostic program could identify the landmarks of each swallow, calculate the parameters and make a final diagnosis within 10 s. The diagnoses made by the automated diagnostic program were not matched to those made by experts in only 10 studies, and the overall accuracy of the new automated diagnostic program thus reached 97.8% (435/445).
Conclusions
The new automated diagnostic program for HREM is clinically useful in terms of high diagnostic accuracy and time-saving.
Objectives
To verify the efficacy and safety of red dichromatic imaging (RDI) in hemostatic procedures during endoscopic submucosal dissection (ESD).
Methods
This is a multicenter randomized ...controlled trial of 404 patients who underwent ESD of the esophagus, stomach, colorectum. Patients who received hemostatic treatments by RDI during ESD were defined as the RDI group (n = 204), and those who received hemostatic treatments by white light imaging (WLI) were defined as the WLI group (n = 200). The primary endpoint was a shortening of the hemostasis time. The secondary endpoints were a reduction of the psychological stress experienced by the endoscopist during the hemostatic treatment, a shortened treatment time, and a non‐inferior perforation rate, in RDI versus WLI.
Results
The mean hemostasis time in RDI (n = 860) was not significantly shorter than that in WLI (n = 1049) (62.3 ± 108.1 vs. 56.2 ± 74.6 s; P = 0.921). The median hemostasis time was significantly longer in RDI than in WLI (36.0 18.0–71.0 vs. 28.0 14.0–66.0 s; P = 0.001) in a sensitivity analysis. The psychological stress was significantly lower in RDI than in WLI (1.71 ± 0.935 vs. 2.03 ± 1.038; P < 0.001). There was no significant difference in the ESD treatment time between RDI (n = 161) and WLI (n = 168) (58.0 35.0–86.0 vs. 60.0 38.0–88.5 min; P = 0.855). Four perforations were observed, but none of them took place during the hemostatic treatment.
Conclusions
Hemostatic treatment using RDI does not shorten the hemostasis time. RDI, however, is safe to use for hemostatic procedures and reduces the psychological stress experienced by endoscopists when they perform hemostatic treatment during ESD.
UMIN000025134.
Background
The values of the parameters in the Chicago classification measured by a high-resolution manometry (HRM) system with the Unisensor catheter (Starlet) are significantly different from those ...measured by the ManoScan. The contraction vigor is categorized by values of the distal contractile integral (DCI) in the Chicago classification v3.0; however, reference values of the DCI in the Starlet and the clinical impact of the different reference values in the Starlet and ManoScan on diagnosing esophageal motility disorders are not known.
Methods
We evaluated data from a previous report in which ManoScan and Starlet were compared in the same subjects. The DCI values in each system were compared and reference DCI values were calculated. Moreover, diagnoses assessed by Starlet using reference values in ManoScan were compared with those using calculated reference values and those assessed by ManoScan.
Results
There was a significant positive correlation between the DCI values measured by ManoScan and those measured by Starlet (
r
= 0.80,
p
< 0.01). Based on a linear functional relationship considering measurement errors, the reference DCI values for diagnosing failed, weak and hypercontractile contraction vigor were calculated as 590.6, 1011.3 and 10,085.8 mmHg-s-cm, respectively, in the Starlet. Therefore, the proposed reference values in the Starlet were 500, 1000 and 10,000 mmHg-s-cm, respectively. When the reference values in the ManoScan were used in the Starlet data, approximately 30% of subjects were diagnosed inappropriately. This issue was resolved using the proposed reference values in the Starlet.
Conclusion
Recognizing systemic differences in HRM systems is important.
Esophagogastroduodenoscopy (EGD) is performed to rule out organic diseases in the diagnosis of esophageal motility disorders (EMDs). Abnormal endoscopic findings can be observed during EGD, which ...indicate the presence of EMDs. Several endoscopic findings at both the esophagogastric junction and esophageal body that are related to EMDs have been reported. Gastroesophageal reflux disease (GERD) and eosinophilic esophagitis (EoE) could be detected during EGD, and these diseases are often associated with abnormal esophageal motility. Image-enhanced endoscopy (IEE) could improve the detection of these diseases during EGD. Although no report has been published previously on the potential usefulness of IEE in the endoscopic diagnosis of EMDs, IEE can be used to detect disorders that can be associated with abnormal esophageal motility.