Optical quality assurance of GEM foils Hildén, T.; Brücken, E.; Heino, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2015, Letnik:
770
Journal Article
Recenzirano
Odprti dostop
An analysis software was developed for the high aspect ratio optical scanning system in the Detector Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used ...e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5μm and 0.3μm, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.
Optical scanning system for quality control of GEM-foils Kalliokoski, M.; Hilden, T.; Garcia, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2012, Letnik:
664, Številka:
1
Journal Article
Recenzirano
An optical scanning system was commissioned and further developed in the Detector Laboratory of Helsinki Institute of Physics and University of Helsinki. It was designed to automatically scan, ...perform on-line analysis and to classify the overall quality of GEM-foils especially of the GEM-TPC detectors for Super-FRS at FAIR. The optical scanning system consists of precision positioning table, lighting, optics and operating system with analysis software. It has active scanning area of 95×95
cm
2 and it can study this area with the minimum resolution of 128
lp/mm. Performance of the system and first results from the GEM-foil uniformity and quality analysis are presented.
The TOTEM T2 telescope based on triple-GEM chambers Bagliesi, M.G.; Berretti, M.; Brucken, E. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2010, Letnik:
617, Številka:
1
Journal Article
Recenzirano
The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the pseudorapidity range
5.3
<
|
η
|
...<
6.5
and a fully inclusive trigger for inelastic events. GEMs are gas filled detectors which combine good spatial resolution with very high rate capability and a good resistance to radiation. Preliminary results of cosmic ray tests performed at CERN on final T2 modules before installation are here presented. Comparisons between real and simulated detector performance are also shown.
A gas electron multiplier (GEM) is a particle detector used in high-energy physics. Its main component is a thin copper-polymer-copper sandwich that carries Ø =70 ± 5 µm holes. Quality assurance ...(QA) is needed to guarantee both long operating life and reading fidelity of the GEM. Absence of layer defects and conformity of the holes to specifications is important. Both hole size and shape influence the detector's gas multiplication factor and hence affect the collected data. For the scanner the required lateral measurement tolerance is ± 5 µm. We calibrated a high aspect ratio optical scanning system (OSS) to allow ensuring the quality of large GEM foils. For the calibration we microfabricated transfer standards, which were imaged with the OSS and which were compared to corresponding scanning electron microscopy (SEM) images. The calibration fulfilled the ISO/IEC 17025 and UKAS M3003 requirements: the calibration factor was 1.01 ± 0.01, determined at 95% confidence level across a 950 × 950 mm2 area. The proposed large-scale scanning technique can potentially be valuable in other microfabricated products too.
The TOTEM experiment at the LHC has performed the first measurement at
s
=
13
TeV
of the
ρ
parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at
t
=
0
, obtaining the ...following results:
ρ
=
0.09
±
0.01
and
ρ
=
0.10
±
0.01
, depending on different physics assumptions and mathematical modelling. The unprecedented precision of the
ρ
measurement, combined with the TOTEM total cross-section measurements in an energy range larger than
10
TeV
(from 2.76 to
13
TeV
), has implied the exclusion of all the models classified and published by COMPETE. The
ρ
results obtained by TOTEM are compatible with the predictions, from other theoretical models both in the Regge-like framework and in the QCD framework, of a crossing-odd colourless 3-gluon compound state exchange in the
t
-channel of the proton–proton elastic scattering. On the contrary, if shown that the crossing-odd 3-gluon compound state
t
-channel exchange is not of importance for the description of elastic scattering, the
ρ
value determined by TOTEM would represent a first evidence of a slowing down of the total cross-section growth at higher energies. The very low-|
t
| reach allowed also to determine the absolute normalisation using the Coulomb amplitude for the first time at the LHC and obtain a new total proton–proton cross-section measurement
σ
tot
=
(
110.3
±
3.5
)
mb
, completely independent from the previous TOTEM determination. Combining the two TOTEM results yields
σ
tot
=
(
110.5
±
2.4
)
mb
.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The TOTEM collaboration has measured the proton–proton total cross section at
s
=
13
TeV
with a luminosity-independent method. Using dedicated
β
∗
=
90
m
beam optics, the Roman Pots were inserted ...very close to the beam. The inelastic scattering rate has been measured by the T1 and T2 telescopes during the same LHC fill. After applying the optical theorem the total proton–proton cross section is
σ
tot
=
(
110.6
±
3.4
) mb, well in agreement with the extrapolation from lower energies. This method also allows one to derive the luminosity-independent elastic and inelastic cross sections:
σ
el
=
(
31.0
±
1.7
)
mb
and
σ
inel
=
(
79.5
±
1.8
)
mb
.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
An optical scanning system was commissioned and further developed in the Detector Laboratory of Helsinki Institute of Physics and University of Helsinki. It was designed to automatically scan, ...perform on-line analysis and to classify the overall quality of GEM-foils especially of the GEM-TPC detectors for Super-FRS at FAIR. The optical scanning system consists of precision positioning table, lighting, optics and operating system with analysis software. It has active scanning area of 95 cm x 95 cm and it can study this area with a resolution of 144 lp/mm. In this paper the performance of the system is studied on different measurement tasks.
The TOTEM collaboration has measured the elastic proton-proton differential cross section
d
σ
/
d
t
at
s
=
13
TeV LHC energy using dedicated
β
∗
=
90
m beam optics. The Roman Pot detectors were ...inserted to 10
σ
distance from the LHC beam, which allowed the measurement of the range 0.04 GeV
2
; 4 GeV
2
in four-momentum transfer squared |
t
|. The efficient data acquisition allowed to collect about 10
9
elastic events to precisely measure the differential cross-section including the diffractive minimum (dip), the subsequent maximum (bump) and the large-|
t
| tail. The average nuclear slope has been found to be
B
=
(
20.40
±
0
.
002
stat
±
0
.
01
syst
)
GeV
-
2
in the |
t
|-range 0.04–0.2 GeV
2
. The dip position is
|
t
dip
|
=
(
0.47
±
0
.
004
stat
±
0
.
01
syst
)
GeV
2
. The differential cross section ratio at the bump vs. at the dip
R
=
1.77
±
0
.
01
stat
has been measured with high precision. The series of TOTEM elastic pp measurements show that the dip is a permanent feature of the pp differential cross-section at the TeV scale.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The TOTEM experiment at the CERN LHC has measured elastic proton–proton scattering at the centre-of-mass energy
s
=
8
TeV and four-momentum transfers squared, |
t
|, from
6
×
10
-
4
to 0.2 GeV
2
. ...Near the lower end of the
t
-interval the differential cross-section is sensitive to the interference between the hadronic and the electromagnetic scattering amplitudes. This article presents the elastic cross-section measurement and the constraints it imposes on the functional forms of the modulus and phase of the hadronic elastic amplitude. The data exclude the traditional Simplified West and Yennie interference formula that requires a constant phase and a purely exponential modulus of the hadronic amplitude. For parametrisations of the hadronic modulus with second- or third-order polynomials in the exponent, the data are compatible with hadronic phase functions giving either central or peripheral behaviour in the impact parameter picture of elastic scattering. In both cases, the
ρ
-parameter is found to be
0.12
±
0.03
. The results for the total hadronic cross-section are
σ
tot
=
(
102.9
±
2.3
)
mb and
(
103.0
±
2.3
)
mb for central and peripheral phase formulations, respectively. Both are consistent with previous TOTEM measurements.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK