SNO+ is a large liquid scintillator-based experiment located 2 km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12 m diameter acrylic ...vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0νββ) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55–133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0νββ Phase I is foreseen for 2017.
In late October 2007, an outbreak of multidrug-resistant Salmonella Newport infections affected 42 case patients in California, Arizona, Idaho, and Nevada. A case-control study implicated ground beef ...from one chain store. Despite detailed ground beef purchase histories--including shopper card information for several case patients--traceback efforts by both the U.S. Department of Agriculture, Food Safety and Inspection Service and the California Department of Public Health were unable to identify the source of contamination. Case patients consumed multiple types of ground beef products purchased at numerous chain store A retail locations. These stores had received beef products for grinding from multiple beef slaughter-processing establishments. Detailed retail grinding logs and grinding policies that prevent cross-contamination between batches of ground beef products are crucial in the identification of contaminated beef products associated with foodborne illness.
SNO+ is a neutrinoless double beta decay and low energy neutrino experiment located in Sudbury, Canada. To improve our understanding of the detector energy resolution and systematics, calibration ...systems have been developed to continuously monitor the optical properties of the detector, such as absorption, reemission and scattering. This poster provides an overview of the scattering calibration system: the Scattering Module of the Embedded LED/Laser Light Injection Entity (SMELLIE), designed to measure the scattering length in situ, over a wavelength range of 375nm - 700nm. We present analyses for both water and scintillator filled detector states.
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a ...spherical acrylic vessel. This paper reports on the analysis of a 758 tonne·day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of 3.9×10−45 cm2 (1.5×10−44 cm2) for a 100 GeV/c2 (1 TeV/c2) WIMP mass at 90% C.L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on the charge and photon detection time distributions observed in each photomultiplier tube.
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The ...projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10−46cm2 for a 100 GeV/c2 WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.
This Letter reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, ...Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 ton day) of data taken during the initial filling phase demonstrates the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage <1.2×10^{-7} (90% C.L.) between 15 and 31 keV_{ee}. No candidate signal events are observed, which results in the leading limit on weakly interacting massive particle (WIMP)-nucleon spin-independent cross section on argon, <1.2×10^{-44} cm^{2} for a 100 GeV/c^{2} WIMP mass (90% C.L.).
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark ...matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP’s 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
The SNO+ experiment Arushanova, E.; Askins, M.; Back, S. ...
Journal of instrumentation,
08/2021, Letnik:
16, Številka:
8
Journal Article
Recenzirano
Odprti dostop
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta (0νββ) decay will be conducted using 780 tonnes of liquid ...scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of 130Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for 0νββ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for 0νββ decay is scalable: a future phase with high 130Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination ...down to an electron-equivalent energy of 20 keVee.
In the surface dataset using a triple-coincidence tag we found the fraction of β events that are misidentified as nuclear recoils to be <1.4×10−7 (90% C.L.) for energies between 43–86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement to be done with only a double-coincidence tag.
The combined data set contains 1.23 × 108 events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the level of electronic recoil contamination is <2.7×10−8 (90% C.L.) between 44–89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale.
We developed a general mathematical framework to describe pulse-shape-discrimination parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approximately 10−10 for an electron-equivalent energy threshold of 15 keVee for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of 10−46 cm2, assuming negligible contribution from nuclear recoil backgrounds.
This paper reports results from a search for nucleon decay through invisible modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. ...However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently deexcite, often emitting detectable gamma rays. A search for such gamma rays yields limits of 2.5×1029 y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and 3.6×1029 y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of 1.3×1028 y for nn, 2.6×1028 y for pn and 4.7×1028 y for pp, an improvement over existing limits by close to 3 orders of magnitude for the latter two.