Purpose
Surgical treatment of jumper’s fractures is a highly demanding situation for the surgeon due to its rareness and frequent association with severe concomitant injuries. There is no current ...consensus regarding a standard treatment approach, thus reducing quality of care. Our objectives were to describe, apply and assess a novel surgical technic.
Methods
The presented research is an observational retrospective study of patients who underwent the described novel surgical intervention in a level 1 trauma center. We conducted analyses of the patient cohort using patient-related outcome measures at least 1 year after surgery, as well as investigating pain, quality of life and the clinical effectiveness of the procedure.
Results
A total of 24 patients (17 male and 7 female) with an average age 47 ± 16.3 years were included. ISS scores ranged from 9 to 66 with a mean ISS of 40 ± 15. Clinical scores exist of 15 out of 24 patients (62.5%). The mean VAS score was 53.7 ± 12.9. The mean EQ-5D index was 0.68 ± 0.22. Significant negative correlation existed between the ISS value and the EQ-5D index (
r
= − 0.704;
p
< 0.005) and EQ-5D VAS (
r
= − 0.809;
p
< 0.001). Anatomical reduction was achieved in all patients (
n
= 24). Radiological follow-up was performed in 58%.
Conclusion
We present one of the largest studies with operatively treated jumper’s fractures of the sacrum. The technique is capable of reproducibly restoring the physiological anatomy of the patient and allows pain-adapted mobilization.
Introduction
In orthopedic surgery, 3D printing is a technology with promising medical applications. Publications show promising results in acetabular fracture surgery over the last years using 3D ...printing. However, only little information about the workflow and circumstances of how to properly derive the 3D printed fracture model out of a CT scan is published.
Materials and methods
We conducted a retrospective analysis of patients with acetabular fractures in a level 1 trauma center. DICOM data were preoperatively used in a series of patients with acetabular fractures. The 3D mesh models were created using 3D Slicer (
https://www.slicer.org
) with a newly introduced surface filtering method. The models were printed using PLA material with FDM printer. After reduction in the printed model, the acetabular reconstruction plate was bent preoperatively and sterilized. A clinical follow-up after 12 months in average was conducted with the patients.
Results
In total, 12 patients included. Mean printing time was 8:40 h. The calculated mean printing time without applying the surface filter was 25:26 h. This concludes an average printing time reduction of 65%. Mean operation time was 3:16 h, and mean blood loss was 853 ml. Model creation time was about 11 min, and mean printing time of the 3D model was 8:40 h, preoperative model reduction time was 5 min on average, and preoperative bending of the plate took about 10 min. After 12 months, patients underwent a structured follow-up. Harris Hip Score was 75.7 points, the Modified Harris Hip Score 71.6 points and the Merle d’Aubigne Score 11.1 points on average.
Conclusions
We presented the first clinical practical technique to use 3D printing in acetabular fracture surgery. By introducing a new surface filtering pipeline, we reduced printing time and cost compared to the current literature and the state of the art. Low costs and easy handling of the 3D printing workflow make it usable in nearly every hospital setting for acetabular fracture surgery.
Operative procedures for unstable pelvic ring fractures remain controversially discussed. Minimally invasive treatment options for pelvic ring fractures have several benefits for the patient. But ...they can also provide disadvantages. Anterior subcutaneous pelvic fixation (INFIX) has shown promising biomechanical results in pelvic ring fractures, but there is a high complication rate of nerve injuries. An additional screw to the INFIX seems to be more stable. The aim of this study is to compare biomechanical stability of a new modified unilateral INFIX fixing the unilateral injured pelvic ring with the standard INFIX.
24 composite synthetic full pelvises were used in this study. 4 groups each with a number of six pelvic specimens were randomly assigned. A C1.3-type pelvic fracture was made with an osteotomy of the sacrum and an osteotomy of the anterior pelvic ring. Fracture fixation was performed within the four groups: (1) unilateral INFIX, (2) "extended" unilateral INFIX + additional pubic ramus pedicle screw, (3) bilateral INFIX, (4) "extended" bilateral INFIX + additional pubic ramus pedicle screw. All specimens were cyclic loaded with 200 N until maximum of 300 N. Distance/dislocation of the fracture fragments were detected with 3D-ultrasound measuring system. Stiffness was calculated.
Extended unilateral INFIX showed the lowest mean dislocation. Lowest rotational stability was displayed by the standard bilateral INFIX. A significant difference (P = 0.04) was shown between the extended unilateral INFIX and the "standard" bilateral INFIX in terms of rotational stability. Extended unilateral INFIX showed significantly improved stability of anterior fracture dislocation (P = 0.01) and unilateral INFIX showed the highest rotational stiffness. Anterior fixation stiffness of the unilateral INFIX was significantly improved using an additional symphysis/pubic ramus screw (P = 0.002).
Extended unilateral INFIX (+ additional pubic ramus pedicle screw) is a feasible minimally invasive treatment for anterior pelvic ring fractures. Higher stability and lower probability of bilateral nerve damage is provided by the extended unilateral INFIX compared to the standard bilateral INFIX.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
: Among the risk factors for nonunion are unchangeable patient factors such as the type of injury and comorbidities, and factors that can be influenced by the surgeon such as fracture treatment and ...the postoperative course. While there are numerous studies analyzing unchangeable factors, there is poor evidence for factors that can be affected by the physician. This raises the need to fill the existing knowledge gaps and lay the foundations for future prevention and in-depth treatment strategies. Therefore, the goal of this study was to illuminate knowledge about nonunion in general and uncover the possible reasons for their development;
: This was a retrospective analysis of 327 patients from 2015 to 2020 from a level I trauma center in Germany. Information about patient characteristics, comorbidities, alcohol and nicotine abuse, fracture classification, type of osteosynthesis, etc., was collected. Matched pair analysis was performed, and statistical testing performed specifically for atrophic long-bone nonunion;
: The type of osteosynthesis significantly affected the development of nonunion, with plate osteosynthesis being a predictor for nonunion. The use of wire cerclage did not affect the development of nonunion, nor did the use of NSAIDs, smoking, alcohol, osteoporosis and BMI;
: Knowledge about predictors for nonunion and strategies to avoid them can benefit the medical care of patients, possibly preventing the development of nonunion.
Early postoperative mobilization is essential for orthogeriatric patients. The prognostic nutritional index (PNI) is widely used to evaluate nutritional status. This study sought to investigate the ...predictive value of PNI for early postoperative mobility in patients with pertrochanteric femur fractures.
This study included 156 geriatric patients with pertrochanteric femur fractures treated with TFN-Advance™ (DePuy Synthes, Raynham, MA, USA). Mobility was evaluated on the third postoperative day and by discharge. Stepwise logistic regression analyses were performed to evaluate the association significance of PNI with postoperative mobility together with comorbidities. The optimal PNI cut-off value for mobility was analyzed using the receiver operating characteristic (ROC) curve.
Three days postoperatively, PNI was an independent predictor of mobility (OR: 1.14, 95% CI: 1.07-1.23,
< 0.01). By discharge, it was found that PNI (OR: 1.18, 95% CI: 1.08-1.30,
< 0.01) and dementia (OR: 0.17, 95% CI: 0.07-0.40,
< 0.001) were significant predictors. PNI correlated weakly with age (r = -0.27,
< 0.001). The PNI cut-off value for mobility on the third postoperative day was 38.1 (specificity = 78.5%, sensitivity = 63.6%).
Our findings indicate that PNI is an independent predictor of early postoperative mobility in geriatric patients with pertrochanteric femur fractures treated with TFNA™.
Osteoporotic proximal femur fractures are on the rise due to demographic change. The most dominant surgical treatment option for per/subtrochanteric fractures is cephalomedullary nailing. As it has ...been shown to increase primary stability, cement augmentation has become increasingly popular in the treatment of osteoporotic per/subtrochanteric femur fractures. The ultimate goal is to achieve stable osteosynthesis, allowing for rapid full weight-bearing to reduce possible postoperative complications. In recent years, bioresorbable bone cements have been developed and are now mainly used to fill bone voids. The aim of this study was to evaluate the biomechanical stability as well as the micro-structural behaviour of bioresorbable bone cements compared to conventional polymethylmethacrylate (PMMA)-cements in a subtrochanteric femur fracture model. Biomechanical as well as micro-computed tomography morphology analysis revealed no significant differences in both bone cements, as they showed equal mechanical stability and tight interdigitation into the spongious bone of the femoral head. Given the positive risk/benefit ratio for bioresorbable bone cements, their utilisation should be evaluated in future clinical studies, making them a promising alternative to PMMA-bone cements.
Background: Gluteal muscle fatty atrophy (gMFA) might impair pelvic stability and negatively influence remobilization in patients with fragility fractures of the pelvis (FFP). This study aimed to ...investigate the association between gMFA and surgical indication in patients with FFP. Methods and materials: A retrospective analysis of 429 patients (age ≥80) diagnosed with FFP was performed. gMFA of the gluteus maximus, medius, and minimus was evaluated using a standard scoring system based on computer tomography images. Results: No significant difference was found in gMFA between genders or among FFP types. The severity of gMFA did not correlate with age. The severity of gMFA in the gluteus medius was significantly greater than in the gluteus maximus, whereas the most profound gMFA was found in the gluteus minimus. gMFA was significantly more severe in patients who underwent an operation than in conservatively treated patients with type-III FFP, and an independent correlation to surgical indication was found using logistic regression. Conclusion: Our findings imply that gMFA is an independent factor for surgical treatment in patients with type-III FFP. Besides focusing on the fracture pattern, the further evaluation of gMFA could be a feasible parameter for decision making toward either conservative or surgical treatment of type-III FFP.
Various risk factors affecting outcome of elderly patients after proximal femur fracture have been identified. The present study aims to evaluate the impact of the fracture pattern in trochanteric ...fractures on postoperative mobility and complications.
Ninety-two patients with a mean age of 84 years were included. According to the revised AO/OTA classification, fractures were divided into stable (AO 31A1) and unstable (AO 31A2/3) patterns. A follow-up examination was performed 12 months after cephalomedullary fixation to assess outcome parameters for mobility/activities of daily living (Parker Mobility Score (PMS)/Barthel Index (BI)) and complications (increase in requirement of care, hospital readmission, mortality rate).
At follow-up, patients with unstable trochanteric fracture patterns presented with lower PMS and BI compared to stable fractures (
< 0.05). Further, higher requirement of care and higher readmission rates compared to stable patterns were observed.
Unstable trochanteric fractures presented inferior outcome compared to simple fracture patterns. This might be explained by the increasing surgical trauma in unstable fractures as well as by the mechanical impact of the lesser trochanter, which provides medial femoral support and is of functional relevance. Subsequent studies should assess if treatment strategies adapted to the specific fracture pattern (refixation of lesser trochanter) influence outcome in unstable trochanteric fractures.
Purpose
Due to the demographic change towards an older society, osteoporosis-related proximal femur fractures are steadily increasing. Intramedullary nail osteosyntheses are available in different ...lengths, where the field of application overlaps. The aim of this study was to investigate whether subtrochanteric fractures can also be treated stably using a short femoral intramedullary nail in cadaveric bones.
Methods
A short PFNA and a long PFNA were implanted in both seven artificial bones and osteoporotic human specimens. A standardized AO 31-A3 (reverse-oblique) fracture was placed in the specimens with a lateral fracture spur 2 cm proximal to the distal locking screw (short PFNA) and embedded. The simulated iliotibial tract was preloaded to 50 N. The force was applied at 10 mm/min up to a force of 200–800 N (artificial bones) and 200–400 N (human specimens). The dislocation of the fracture gap, the axial bone stiffness of bone construct and the force curve of the tractus iliotibialis were measured.
Results
There is no difference in the use of a short versus long PFNA in terms of stiffness of the overall construct and only a slight increase in dislocation in the fracture gap results with short PFNA compared to a long intramedullary nail.
Conclusion
In summary of the available literature, the present study supports the thesis that there is no clinical difference between long versus short nails in A3 femur fractures. Furthermore, the present study defines a safe biomechanical range of fracture extension above the locking screw of the short intramedullary nail.
Level of Evidence
III