MicroRNAs are a class of small, non‐coding RNAs that can negatively regulate protein‐coding genes, and are associated with almost all known physiological and pathological processes, especially ...cancer. The number of studies documenting miRNA expression patterns in malignancy continues to expand rapidly, with continuously gained critical information regarding how aberrantly expressed miRNAs may contribute to carcinogenesis. miRNAs can influence cancer pathogenesis, playing a potential role as either oncogenes or tumour suppressors. Recently, several miRNAs have been reported to exert different regulatory functions in oesophageal cancer – the carcinoma typically arising from the epithelial lining of the oesophagus. These miRNAs also have potential clinical applications towards developing biomarkers or targets for possible use in diagnosis or therapy in oesophageal cancer. In this review, we have summarized the two (oncogenic or tumour suppressive) roles of miRNAs here, and their applications as potential biomarkers or therapeutic targets, which may illuminate future treatment for oesophageal cancer.
By combining angle-resolved photoemission spectroscopy and quantum oscillation measurements, we performed a comprehensive investigation on the electronic structure of LaSb, which exhibits ...near-quadratic extremely large magnetoresistance (XMR) without any sign of saturation at magnetic fields as high as 40 T. We clearly resolve one spherical and one intersecting-ellipsoidal hole Fermi surfaces (FSs) at the Brillouin zone (BZ) center Γ and one ellipsoidal electron FS at the BZ boundary X. The hole and electron carriers calculated from the enclosed FS volumes are perfectly compensated, and the carrier compensation is unaffected by temperature. We further reveal that LaSb is topologically trivial but shares many similarities with the Weyl semimetal TaAs family in the bulk electronic structure. Based on these results, we have examined the mechanisms that have been proposed so far to explain the near-quadratic XMR in semimetals.
The process e+e- → Λ Λ ¯ is studied using data samples at √s = 2.2324, 2.400, 2.800 and 3.080 GeV collected with the BESIII detector operating at the BEPCII collider. The Born cross section is ...measured at √s=2.2324 GeV, which is 1.0 MeV above the Λ Λ ¯ mass threshold, to be 305±$45_{-36}^{+66}$ pb, where the first uncertainty is statistical and the second systematic. The substantial cross section near threshold is significantly larger than that expected from theory, which predicts the cross section to vanish at threshold. The Born cross sections at √s=2.400, 2.800 and 3.080 GeV are measured and found to be consistent with previous experimental results, but with improved precision. Finally, the corresponding effective electromagnetic form factors of Λ are deduced.
To assess the accuracy of Magnetic Resonance Index of Activity (MaRIA) in evaluating therapeutic efficacy in Crohn's disease (CD) patients with different activity levels using ileocolonoscopy as the ...reference standard.
Forty-eight patients underwent magnetic resonance enterography (MRE) and ileocolonoscopy at baseline, week 26, and week 52, along with the Simple Endoscopic Score for Crohn's Disease (SES-CD) and MaRIA scores. According to the SES-CD score at baseline, all patients were subdivided into mild, moderate, and severe activity subgroups. The identification of endoscopic mucosal healing (MH) was explored primarily. Moreover, the Crohn's Disease Activity Index (CDAI), C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), procalcitonin (PCT), and interleukin-6 (IL-6) levels were collected and analysed.
MaRIA correlated significantly with SES-CD and CRP at baseline, week 26, and week 52. The discrepancies in MaRIA and SES-CD were statistically significant before and after treatment. MaRIA = 24.43 and ΔMaRIA = 12.77 as the cut-off points were found to have high diagnostic accuracy for predicting MH. MaRIA (p<0.001), SES-CD (p<0.001), CRP (p<0.05), ESR (p<0.05), and CDAI score (p<0.05) in patients with MH were considerably decreased compared to those in patients without MH.
MRE has good application value in evaluating the therapeutic response of CD patients treated with biological agents. MaRIA is a reliable indicator in the follow-up of CD patients, which is strongly correlated with SES-CD, and it has high accuracy in predicting endoscopic MH.
•MRE was a valuable imaging method to evaluate the therapeutic effect of CD patients.•MaRIA is strongly correlated with SES-CD.•MaRIA is a trustworthy indicator in the predicting endoscopic mucosal healing.
Abstract
We report on analysis of observations of the bright transient X-ray pulsar Swift J0243.6+6124 obtained during its 2017-2018 giant outburst with Insight-HXMT, NuSTAR, and Swift observatories. ...We focus on the discovery of a sharp state transition of the timing and spectral properties of the source at super-Eddington accretion rates, which we associate with the transition of the accretion disk to a radiation pressure dominated (RPD) state, the first ever directly observed for magnetized neutron star. This transition occurs at slightly higher luminosity compared to already reported transition of the source from sub- to super-critical accretion regime associate with onset of an accretion column. We argue that this scenario can only be realized for comparatively weakly magnetized neutron star, not dissimilar to other ultra-luminous X-ray pulsars (ULPs), which accrete at similar rates. Further evidence for this conclusion is provided by the non-detection of the transition to the propeller state in quiescence which strongly implies compact magnetosphere and thus rules out magnetar-like fields.
The cross section of the process e+e−→K+K− is measured at a number of center-of-mass energies s from 2.00 to 3.08 GeV with the BESIII detector at the Beijing Electron Positron Collider (BEPCII). The ...results provide the best precision achieved so far. A resonant structure around 2.2 GeV is observed in the cross section line shape. A Breit-Wigner fit yields a mass of M=2239.2±7.1±11.3 MeV/c2 and a width of Γ=139.8±12.3±20.6 MeV, where the first uncertainties are statistical and the second ones are systematic. In addition, the timelike electromagnetic form factor of the kaon is determined at the individual center-of-mass energy points.
The cross section of the e+e−→Λc+Λ¯c− process is measured with unprecedented precision using data collected with the BESIII detector at /¯s=4574.5, 4580.0, 4590.0 and 4599.5 MeV. The nonzero cross ...section near the Λc+Λ¯c− production threshold is cleared. At center-of-mass energies /¯s=4574.5 and 4599.5 MeV, the higher statistics data enable us to measure the Λc polar angle distributions. From these, the Λc electric over magnetic form-factor ratios (|GE/GM|) are measured for the first time. They are found to be 1.14±0.14±0.07 and 1.23±0.05±0.03, respectively, where the first uncertainties are statistical and the second are systematic.
Abstract
Spin-valley locking in monolayer transition metal dichalcogenides has attracted enormous interest, since it offers potential for valleytronic and optoelectronic applications. Such an exotic ...electronic state has sparsely been seen in bulk materials. Here, we report spin-valley locking in a Dirac semimetal BaMnSb
2
. This is revealed by comprehensive studies using first principles calculations, tight-binding and effective model analyses, angle-resolved photoemission spectroscopy measurements. Moreover, this material also exhibits a stacked quantum Hall effect (QHE). The spin-valley degeneracy extracted from the QHE is close to 2. This result, together with the Landau level spin splitting, further confirms the spin-valley locking picture. In the extreme quantum limit, we also observed a plateau in the
z
-axis resistance, suggestive of a two-dimensional chiral surface state present in the quantum Hall state. These findings establish BaMnSb
2
as a rare platform for exploring coupled spin and valley physics in bulk single crystals and accessing 3D interacting topological states.