In patients undergoing transcatheter aortic-valve replacement, defects in high-molecular-weight von Willebrand factor multimers and the closure time with adenosine diphosphate (a measure of ...hemostasis) were closely correlated with postprocedural aortic regurgitation.
Postprocedural aortic regurgitation, usually due to paravalvular leak, occurs in 10 to 20% of patients with aortic stenosis who undergo transcatheter aortic-valve replacement (TAVR).
1
–
3
Patients with aortic regurgitation that is more than mild after TAVR have poorer outcomes than those without aortic regurgitation, including increased rates of rehospitalization, death from cardiac causes, and death from any cause at 1 year.
4
Ideally, aortic regurgitation after TAVR should be detected at the time of the procedure, because correction maneuvers can be undertaken immediately. However, despite the combined use of angiography, echocardiography, and hemodynamic evaluation, it is very difficult to identify and . . .
The main risk factor for bleeding in patients with continuous-flow mechanical circulatory support (CF-MCS) is the acquired von Willebrand factor (VWF) defect related to the high shear-stress forces ...developed by these devices. Although a higher bleeding rate has been reported in CF-MCS recipients who had reduced pulsatility, the relation between pulsatility and the VWF defect has never been studied.
The purpose of this study was to investigate the relation between pulsatility and VWF under CF-MCS.
We assessed the effect of 2 CF-MCS on VWF multimer degradation in a mock circulatory loop (model 1). Using these devices, we investigated in a dose-effect model (model 2) 3 levels of pulsatility in 3 groups of swine. In a cross-over model (model 3), we studied the effects of sequential changes of pulsatility on VWF. We reported the evolution of VWF multimerization in a patient undergoing serial CF-MCS and/or pulsatile-MCS.
We demonstrated the proteolytic degradation of VWF multimers by high shear CF-MCS in a circulatory loop without pulsatility. We observed both in swine models and in a patient that the magnitude of the VWF degradation is modulated by the pulsatility level in the high shear-stress level condition, and that the restoration of pulsatility is a trigger for the endothelial release of VWF.
We demonstrated that the VWF defect reflects the balance between degradation induced by the shear stress and the endothelial release of new VWF triggered by the pulsatility. This modulation of VWF levels could explain the relationship between pulsatility and bleeding observed in CF-MCS recipients. Preservation of pulsatility may be a new target to improve clinical outcomes of patients.
Display omitted
Highlights • Mycoplasma hominis has become an established cause of mediastinitis. • M. hominis is not usually covered by the empiric antimicrobial therapy. • A prolonged incubation may help to ...recover M. hominis but not Ureplasma spp. • 16S rDNA sequencing is useful in case of culture negative mediastinitis.
Valve-sparing aortic root replacement with the David procedure is an alternative to the Bentall procedure in patients with aortic root aneurysm. The aim of this study was to describe our long-term ...experience with this technique and the predictive factors of late failure.
Between January 1998 and August 2019, 300 consecutive patients underwent a David procedure. Clinical and echocardiographic early- and long-term outcomes were analyzed. Median follow-up was 7.0 years (range, 4.1-11.5), with 98.3% complete.
Early mortality was 1%. No early valve-related reoperations occurred. There were 9 cardiac-related deaths and 22 reinterventions (19 valve-related). All patients survived reoperation. In 3 patients reintervention consisted of transcatheter aortic valve implantation. Overall survival rates were 95.3% (95% confidence interval CI, 92.0-97.2), 91.1% (95% CI, 86.5-94.2), and 82.9% (95% CI, 75.3-88.4) at 5, 10, and 15 years, respectively. Freedom from postoperative aortic insufficiency (AI) grade ≥ 2 was 84.8% (95% CI, 79.9-88.6) and 74.3% (95% CI, 67.4-79.9) at 5 and 10 years, respectively. Freedom from reintervention for aortic valve disease was 97.1% (95% CI, 94.2-98.5), 92.9% (95% CI, 88.2-95.7), and 92.5% (95% CI, 87.1-95.7) at 5, 10, and 15 years, respectively. Preoperative AI ≥ 2 (hazard ratio, 1.782; 95% CI, 1.352-2.350) and a ventriculoaortic junction ≥ 29 mm (hazard ratio, 3.379; 95% CI, 1.726-6.616) were predictive factors for postoperative AI ≥ 2 in a multivariate analysis (P < .001).
Preoperative AI ≥ 2 and a ventriculoaortic junction ≥ 29 mm were identified as risk factors for late postoperative AI ≥ 2.
Display omitted
For decades, numerous observations have shown an intimate relationship between von Willebrand factor (VWF) multimer profile and heart valve diseases (HVD). The current knowledge of the unique ...biophysical properties of VWF helps us to understand the longstanding observations concerning the bleeding complications in patients with severe HVD. Not only does the analysis of the VWF multimer profile provide an excellent evaluation of HVD severity, it is also a strong predictor of clinical events. Also of importance, VWF responds within minutes to any significant change in hemodynamic valve status, making it an accurate marker of the quality of surgical and transcatheter therapeutic interventions. The authors provide in this review a practical, comprehensive, and evidence-based framework of the concept of VWF as a biomarker in HVD, advocating for its implementation into the clinical decision-making process besides usual clinical and imaging evaluation. They also delineate critical knowledge gaps and research priorities to definitely validate this concept.
Purpose
To describe bleeding and thrombotic events and their risk factors in patients receiving extracorporeal membrane oxygenation (ECMO) for severe coronavirus disease 2019 (COVID-19) and to ...evaluate their impact on in-hospital mortality.
Methods
The ECMOSARS registry included COVID-19 patients supported by ECMO in France. We analyzed all patients included up to March 31, 2022 without missing data regarding bleeding and thrombotic events. The association of bleeding and thrombotic events with in-hospital mortality and pre-ECMO variables was assessed using multivariable logistic regression models.
Results
Among 620 patients supported by ECMO, 29% had only bleeding events, 16% only thrombotic events and 20% both bleeding and thrombosis. Cannulation site (18% of patients), ear nose and throat (12%), pulmonary bleeding (9%) and intracranial hemorrhage (8%) were the most frequent bleeding types. Device-related thrombosis and pulmonary embolism/thrombosis accounted for most of thrombotic events. In-hospital mortality was 55.7%. Bleeding events were associated with in-hospital mortality (adjusted odds ratio (adjOR) = 2.911.94–4.4) but not thrombotic events (adjOR = 1.020.68–1.53). Intracranial hemorrhage was strongly associated with in-hospital mortality (adjOR = 13.54.4–41.5). Ventilation duration before ECMO ≥ 7 days and length of ECMO support were associated with bleeding. Thrombosis-associated factors were fibrinogen ≥ 6 g/L and length of ECMO support.
Conclusions
In a nationwide cohort of COVID-19 patients supported by ECMO, bleeding incidence was high and associated with mortality. Intracranial hemorrhage incidence was higher than reported for non-COVID patients and carried the highest risk of death. Thrombotic events were less frequent and not associated with mortality. Length of ECMO support was associated with a higher risk of both bleeding and thrombosis, supporting the development of strategies to minimize ECMO duration.