Abstract Subclinical leaflet thrombosis was recently described in a randomized trial of transcatheter aortic valve replacement. It was subsequently demonstrated in a series of registries that this ...was a commonly observed imaging finding seen in all transcatheter and surgical bioprostheses. The phenomenon has aroused considerable interest due to the as-yet-undefined risk for later clinical events and the possibility of pharmacological intervention with anticoagulation. Subclinical leaflet thrombosis is easily detected noninvasively by technically suitable computed tomography (CT) with a high degree of concordance to transesophageal echocardiography findings. The CT hallmarks were noted to be hypoattenuated leaflet thickening (HALT) associated with reduced leaflet motion (RELM). The combination of HALT and RELM signified hypoattenuation affecting motion, the standardized imaging endpoint used. This paper describes the systematic CT evaluation methodology that was devised during the Portico trial investigation and U.S. Food and Drug Administration submission; it also highlights the need for an ongoing discussion among experts to enable, with the help of the Valve Academic Research Consortium, standardization of reporting of this imaging finding to cater to the present and future needs of clinical trials.
Abstract Objectives This study sought to develop a robust and definitive risk model for new permanent pacemaker implantation (PPMI) after SAPIEN 3 (third generation balloon expandable valve) (Edwards ...Lifesciences, Irvine, California) transcatheter aortic valve replacement (third generation balloon expandable valve TAVR), including calcification in the aortic-valvular complex (AVC). Background The association between calcium in the AVC and need for PPMI is poorly delineated after third generation balloon expandable valve TAVR. Methods At Cedars-Sinai Heart Institute in Los Angeles, California, a total of 240 patients with severe aortic stenosis underwent third generation balloon expandable valve TAVR and had contrast computed tomography. AVC was characterized precisely by leaflet sector and region. Results The total new PPMI rate was 14.6%. On multivariate analysis for predictors of PPMI, pre-procedure third generation balloon expandable valve TAVR, right bundle branch block (RBBB), shorter membranous septum (MS) length, and noncoronary cusp device-landing zone calcium volume (NCC-DLZ CA) were included. Predictive probabilities were generated using this logistic regression model. If 3 pre-procedural risk factors were present, the c-statistic of the model for PPMI was area under the curve of 0.88, sensitivity of 77.1%, and specificity of 87.1%; this risk model had high negative predictive value (95.7%). The addition of the procedural factor of device depth to the model, with the parameter of difference between implantation depth and MS length, combined with RBBB and NCC-DLZ CA increased the c-statistic to 0.92, sensitivity to 94.3%, specificity to 83.8%, and negative predictive value to 98.8% Conclusions By using a precise characterization of distribution of calcification in the AVC in a single-center, retrospective study, NCC-DLZ CA was found to be an independent predictor of new PPMI post–third generation balloon expandable valve TAVR. The findings also reinforce the importance of short MS length, pre-existing RBBB, and ventricular implantation depth as important synergistic PPMI risk factors. This risk model will need validation by future prospective multicenter studies.
Four-dimensional volume-rendered computed tomography (4DCT) has demonstrated instances of hypo-attenuating leaflet thickening (HALT) with or without hypo-attenuation affecting motion (HAM) after ...transcatheter and surgical aortic valve implantation (TAVI, SAVR). The temporal pattern of evolution of these phenomena is uncertain.
The SAVORY registry enrolled patients treated by TAVI (n = 75) or SAVR (n = 30) with two 4DCT scans fully interpretable for HALT and HAM as well as unchanged anti-thrombotic medication between the scans. Logistic regression analysis was performed to examine the evolution of HALT and HAM while accounting for demographic and baseline variables, timing of both CT scans, valve type and antithrombotic therapy. The analysis population consisted of 84 patients, in whom first and second CT scans were performed at 140 ± 152 days and 298 ± 141 days after valve implantation, respectively. Hypo-attenuating leaflet thickening was noted in 32 patients (38.1%), with HAM in 17 (20.2%). Both findings were dynamic, showing progression in 13 (15.5%) and regression and 9 (10.7%) patients. Compared with antiplatelet therapy, progression was less likely among patients on oral anticoagulation with vitamin-K antagonists or non-VKA oral anticoagulants (odds ratio: 0.014, P = 0.036). Maintenance on chronic oral anticoagulation was not a significant predictor of regression. These findings were similar for both transcatheter and surgical bioprosthetic aortic valves. No patients developed symptoms of valve dysfunction and leaflet thickening was not clearly associated with any clinical events.
Subclinical leaflet thrombosis is a common finding after TAVI and SAVR, and may progress from normal leaflet over HALT to the more severe HAM. The phenomenon can develop and regress at variable intervals after valve implantation. Anticoagulants may have a protective effect against the development of HALT, but HALT can also regress without anticoagulation therapy.
NCT02426307.
Background: Transcatheter aortic valve-in-valve (VIV) replacement within failed bioprosthetic surgical aortic valves is a feasible therapeutic option. However, data comparing the hemodynamic and ...clinical outcomes of VIV replacement with supra-annular self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. Methods and Results: Outcomes of 40 and 95 patients treated with supra-annular self-expanding and balloon-expandable THV, respectively, were compared after propensity score matching, which yielded 37 pairs of patients with similar baseline characteristics. Hemodynamic and clinical outcomes were analyzed. Postprocedural mean gradient was significantly lower in the self-expanding THV group than in the balloon-expandable THV group (12.1±6.1 mmHg vs. 19.0±7.3 mmHg, P<0.001). The incidence of at least mild postprocedural aortic regurgitation (AR) was comparable between the self-expanding and balloon-expandable THV groups (21.6% vs. 10.8%, P=0.39). In the self-expanding THV group, the new-generation THV showed a trend towards a lower incidence of at least mild AR compared with the early-generation THV (12.5% vs. 38.5%, P=0.07). A similar trend was observed in the balloon-expandable THV group (4.2% vs. 23.1%, P=0.08). There was no significant difference between the self-expanding and balloon-expandable THV groups in the cumulative 2-year all-cause mortality rates (22.4% vs. 43.4%, log-rank P=0.26). Conclusions: The supra-annular self-expanding THV was associated with a lower postprocedural mean gradient compared with balloon-expandable THV in patients undergoing aortic VIV replacement.
Abstract Objectives This study sought to evaluate transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) aortic stenosis (AS), with a particular emphasis on TAVR-directed ...bicuspid aortic valve imaging (BAVi) of morphological classification. Background TAVR has been used to treat BAV-AS but with heterogeneous outcomes and uncertainty regarding the relevance of morphology. Methods In 14 centers in the United States, Canada, Europe, and Asia, 130 BAV-AS patients underwent TAVR. Baseline cardiac computed tomography (CT) was analyzed by a dedicated Corelab. Outcomes were assessed in line with Valve Academic Research Consortium criteria. Results Bicommissural BAV (vs. tricommissural) accounted for 68.9% of those treated in North America, 88.9% in Europe, and 95.5% in Asia (p = 0.003). For bicommissural bicuspids, non-raphe type (vs. raphe type) BAV accounted for 11.9% of those treated in North America, 9.4% in Europe, and 61.9% in Asia (p < 0.001). Overall rates of 30-day mortality (3.8%) and cerebrovascular events (3.2%) were favorable and similar among anatomical subsets. The rate of new permanent pacemaker insertion was high (26.2%) and similar between balloon-expandable (BE) and self-expanding (SE) designs (BE: 25.5% vs. SE: 26.9%; p = 0.83); there was a trend to greater permanent pacemaker insertion in BE TAVR in the presence of coronary cusp fusion BAV morphology. Paravalvular aortic regurgitation (PAR) ≥ moderate was 18.1% overall but lower at 11.5% in those with pre-procedural CT. In the absence of pre-procedural CT, there was an excess of PAR in BE TAVR that was not the case in those with a pre-procedural CT; SE TAVR required more post-dilation. Predictors of PAR included intercommissural distance for bicommissural bicuspids (odd ratio OR: 1.37; 95% confidence interval CI: 1.02 to 1.84; p = 0.036) and lack of a baseline CT for annular measurement (OR: 3.03; 95% CI: 1.20 to 7.69; p = 0.018). Conclusions In this multicenter study, TAVR achieved favorable outcomes in patients with pre-procedural CT, with the exception of high permanent pacemaker rates for all devices and shapes.
Several clinical variables have been identified as predictors of clinical outcome after transcatheter aortic valve implantation (TAVI). Nonetheless, there is limited and contradictive data on the ...impact of diabetes mellitus (DM) on the prognosis of patients who undergo TAVI. We aimed to investigate the clinical characteristics and the early and midterm outcomes after TAVI according to DM status. From 802 consecutive patients who underwent TAVI, we compared 548 patients with no DM to 254 patients with diabetes (177 orally treated and 77 insulin treated). Patients with DM were younger had higher body mass index and incidence of coronary artery disease and lower incidence of frailty. Device success, 30-day mortality and major complications rates were similar between groups. One-year mortality was 12.1% for patient with DM and 12.2% for patients without DM (p = 0.91). In a multivariable regression analysis including age, body mass index, coronary artery disease and frailty, DM was associated with decreased overall survival. This was driven by increased overall mortality of the insulin-treated DM subgroup (hazard ratio 2.40, 95% CI 1.32 to 4.37; p <0.01). In conclusion, DM does not affect short-term mortality or rates of complications after TAVI. Insulin-treated DM, but not orally treated DM, is independently associated with death at midterm follow-up and therefore aggressive cardiovascular risk factor modification as well as intense glycemic control should be considered for patients with insulin-treated DM with severe aortic stenosis who undergo TAVI.
Abstract Objectives The aim of this study was to evaluate the impact of increased aortic angulation (AA) on acute procedural success following transcatheter aortic valve replacement (TAVR). ...Background The degree of angulation between the aorta and the heart can make accurate positioning of the bioprosthesis during TAVR more demanding, particularly in instances of an extremely angulated or horizontal aortic root. Nonetheless, there are limited data on the impact of AA on the acute success of TAVR. Methods We assessed 582 patients who underwent TAVR at our institute and had contrast computed tomography available for AA evaluation. TAVR endpoints, device success, and adverse events were considered according to the Valve Academic Research Consortium-2 definitions. Results The mean angulation of the aorta was 47.3 ± 8.7°. Patients were therefore divided into 2 groups: AA <48° and AA ≥48°. AA in the 480 patients who underwent balloon-expandable (BE) TAVR did not influence acute procedural success or short-term clinical outcome. In contrast, increased AA among the 102 patients who underwent self-expandable (SE) TAVR was found to significantly attenuate procedural success (area under the curve: 0.73; 95% confidence interval: 0.61 to 0.85; p = 0.008). The numerical cutoff for AA with the highest sum of sensitivity and specificity for device success was ≥48° (sensitivity 85%, specificity 61%). Moreover, patients whose AA was ≥48° were also associated with an increased need for a second valve and post-dilation, had increased fluoroscopy time and increased valve embolization, and had increased post-procedural paravalvular regurgitation greater than or equal to mild following SE TAVR. Major complications at 30 days, including mortality were similar between AA groups. Six-month mortality was also similar between both AA groups. Conclusions Increased aortic root angulation adversely influences acute procedural success following SE but not BE TAVR. Because of these data, BE valves may be preferred when evaluating patients with high AA before TAVR.
Background: Patients with severe aortic stenosis (AS) and an extra-large annulus (ELA) area (>683 mm2) can rarely be treated by transcatheter aortic valve replacement (TAVR) because of the size ...limitation of the transcatheter heart valves. This study aimed to evaluate the feasibility of TAVR using a 29-mm SAPIEN3 (S3) valve in patients with ELA and S3-dimensions by post-procedural computed tomography (post-CT). Methods and Results: We included 261 patients undergoing TAVR using a 29-mm S3: 30 patients with ELA and 231 with non-ELA were identified. S3-dimensions were evaluated at the S3 inflow and annulus level by post-CT in 129 patients. The ELA group had a greater aortic annulus area measured by pre-procedural CT (737.3±54.7 vs. 578.4±41.9 mm2, P<0.0001), higher balloon inflation volume (36 vs. 33 mL, P<0.0001), a larger S3 area at inflow by post-CT (729.6±42.2 vs. 682.2±35.0 mm2, P<0.001), and a correlation between the inflation volume and S3 area (r=0.71, P=0.0005). No differences were observed between groups in paravalvular aortic regurgitation (PAR) ≥mild (43.3% vs. 27.6%, P=0.09), PAR ≥moderate (3.3% vs. 1.3%, P=0.39) or 1-year mortality (10.0% vs. 9.1%, P=0.87). Conclusions: TAVR using a 29-mm S3 with extra inflation of the delivery balloon can be considered as a treatment option for patients with severe AS and ELA.
Stent-frame morphology of the newer-generation, balloon-expandable transcatheter heart valve (THV), the SAPIEN 3 (S3), after transcatheter aortic valve implantation (TAVI) is unknown. We evaluated ...the THV stent-frame morphology post TAVI of the S3 using multi-slice computed tomography (MSCT) compared with the prior-generation THV, SAPIEN XT (S-XT).
A total of 94 consecutive participants of RESOLVE registry (NCT02318342) had MSCT after balloon-expandable TAVI (S3 = 39 and S-XT = 55). The morphology of the THV stent-frame was evaluated for expansion area and eccentricity at the THV-inflow, native annulus, mid-THV and THV-outflow levels. Mean %-expansion area for the S3 and the S-XT was 100.9 ± 5.7 and 96.1 ± 5.5%, respectively (P < 0.001). In the S3 group, the THV-inflow level had the largest value of %-expansion area, which decreased from THV-inflow to mid-THV level (105.2 ± 6.4 to 96.5 ± 5.9%, P < 0.001). However, in the S-XT group, %-expansion area increased from THV-inflow level to mid-THV level (93.2 ± 6.2 to 95.1 ± 6.1%, P = 0.0058). On nominal delivery balloon volume, the S3 in 88.5% of cases had overexpansion at the THV-inflow level. The observed degree of THV oversizing of the S3 was significantly lower than the S-XT (6.3 ± 8.6 vs. 11.8 ± 8.5%, P = 0.0027). Nonetheless, the incidence of post-procedural paravalvular aortic regurgitation (PVR) ≥ mild following the S3 TAVI was also significantly lower than the S-XT TAVI (17.9 vs. 43.6%, P = 0.014).
The newer-generation, balloon-expandable device, the S3, has a flared inflow morphology, whereas the prior-generation device, the S-XT, has relatively constrained inflow morphology post TAVI. This may contribute to a lesser degree of PVR with the S3.
Coronary protection with guidewires and an undeployed coronary balloon or stent positioned in the coronary artery is a pre-emptive technique to manage coronary obstruction during transcatheter aortic ...valve implantation (TAVI). We investigated the feasibility and safety of left main (LM) protection during TAVI.
Twenty-five out of 623 patients who underwent TAVI at our institute were deemed to be at increased risk of LM compromise mainly due to a low LM ostium height, significant LM disease or a previous bioprosthetic valve. A pre-emptive LM protection technique was therefore used in these cases. Five patients (20%) had pre-TAVI significant non-revascularised LM stenosis, and four patients (16%) had a prior LM ostial stent without pre-TAVI in-stent restenosis. Twelve patients had extremely low LM height (mean height 6.7±2.4 mm; range 1.1-8.9 mm). Seven patients (25%) had valve-in-valve (VIV) procedures. LM compromise occurred in five out of 25 cases; all were treated successfully with emergency LM stenting. Nine patients underwent successful planned LM procedures following TAVI.
The LM protection technique should be considered in patients deemed to be at increased risk of LM compromise. This was found to be helpful in the prompt diagnosis and treatment of LM compromise following TAVI.