Background
Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro‐ and nanodosimetry, imaging, radiation protection, and nuclear ...medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing.
Aims
To respond to these needs, we developed G4‐Med, a benchmarking and regression testing system of Geant4 for medical physics.
Materials and Methods
G4‐Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4‐Med are executed on the CERN computing infrastructure via the use of the geant‐val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes.
Results
This paper describes the tests included in G4‐Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.
Discussion
Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics.
Conclusion
The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
•Artificial intelligence is used for assessing response to therapy in rectal cancer.•Textural features extraction from high resolution 3 T MR images.•Artificial intelligence model helps personalize ...therapeutic strategy.•Decisions curves analysis confirm clinical utility.
To develop and validate an Artificial Intelligence (AI) model based on texture analysis of high-resolution T2 weighted MR images able 1) to predict pathologic Complete Response (CR) and 2) to identify non-responders (NR) among patients with locally-advanced rectal cancer (LARC) after receiving neoadjuvant chemoradiotherapy (CRT).
Fifty-five consecutive patients with LARC were retrospectively enrolled in this study. Patients underwent 3 T Magnetic Resonance Imaging (MRI) acquiring T2-weighted images before, during and after CRT. All patients underwent complete surgical resection and histopathology was the gold standard. Textural features were automatically extracted using an open-source software. A sub-set of statistically significant textural features was selected and two AI models were built by training a Random Forest (RF) classifier on 28 patients (training cohort). Model performances were estimated on 27 patients (validation cohort) using a ROC curve and a decision curve analysis.
Sixteen of 55 patients achieved CR. The AI model for CR classification showed good discrimination power with mean area under the receiver operating curve (AUC) of 0.86 (95% CI: 0.70, 0.94) in the validation cohort. The discriminatory power for the NR classification showed a mean AUC of 0.83 (95% CI: 0.71,0.92). Decision curve analysis confirmed higher net patient benefit when using AI models compared to standard-of-care.
AI models based on textural features of MR images of patients with LARC may help to identify patients who will show CR at the end of treatment and those who will not respond to therapy (NR) at an early stage of the treatment.
Abstract
One of today’s main challenges in molecular radiation therapy is to assess an individual dosimetry that allows treatment to be tailored to the specific patient, in accordance with the ...current paradigm of ‘personalized medicine’. The evaluation of the absorbed doses for tumor and organs at risk in molecular radiotherapy is typically based on MIRD schema acquiring few experimental points for the assessement of biokinetic parameters. WIDMApp, the wearable individual dose monitoring apparatus, is an innovative approach for internal dosimetry based on a wearable radiation detecting system for individual biokinetics sampling, a Monte Carlo simulation for particle interaction, and an unfolding algorithm for data analysis and integrated activity determination at organ level. A prototype of a WIDMApp detector element was used to record the photon emissions in a body phantom containing 3 spheres with liquid sources (
18
F,
64
Cu and
99
m
Tc) to simulate organs having different washout. Modelling the phantom geometry on the basis of a CT scan imaging, the Monte Carlo simulation computed the contribution of each emitting sphere to the signal detected in 3 positions on the phantoms surface. Combining the simulated results with the data acquired for 120 h, the unfolding algorithm deconvolved the detected signal and assessed the decay half-life (
T
1/2
) and initial activity values (
A
(0)) that best reproduces the observed exponential decays. A 3%–18% level of agreement is found between the actual
A
(0) and
T
1/2
values and those obtained by means of the minimization procedure based on the Monte Carlo simulation. That resulted in an estimation of the cumulated activity <15%. Moreover, WIDMApp data redundancy has been used to mitigate some experimental occurrences that happened during data taking. A first experimental test of the WIDMApp approach to internal radiation dosimetry is presented. Studies with patients are foreseen to validate the technique in a real environment.
Radioguided surgery (RGS) is a medical practice which thanks to a radiopharmaceutical tracer and a probe allows the surgeon to identify tumor residuals up to a millimetric resolution in real-time. ...The employment of β− emitters, instead of γ or β+, reduces background from healthy tissues, administered activity to the patient, and medical exposure. In a previous work the possibility of using a CMOS Imager (Aptina MT9V011), initially designed for visible light imaging, to detect β− from 90Y or 90Sr sources has been established. Because of its possible application as counting probe in RGS, the performances of MT9V011 in clinical-like conditions were studied.11This work financed by Istituto Nazionale Fisica Nucleare, Italy, project CHIR2, and partially supported by Universitá degli Studi di Perugia, Italy , Fondo Ricerca di Base 2017, project SEISIPO.
Through horizontal scans on a collimated 90Sr source of different sizes (1, 3, 5, 7 mm), we have determined relationships between scan fit parameters and the source dimension, namely A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter, are determined. Horizontal scan measurements on a source, interposing collimators of different size, aim to determine relationships or correlations between scan fit parameters and source dimension. A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter are determined.
In order to get closer to clinical conditions, agar–agar phantoms containing 90Y with different dimensions and activities were prepared. A 90Y phantom is characterized by a central spot and a ring all around, for simulating both signal (tumor) and background (surrounding healthy tissue). The relationship found between scan maximum and 90Sr source diameter is then exploited to extract the concentration ratio between spot and external ring of the 90Y phantom. This observable, defined as the ratio between the tumor and the nearby healthy tissues uptake simulates the Tumor-to-Non-tumor Ratio (TNR). With the aim of evaluating the sensor’s ability to discriminate signal from background relying on the significance parameter, a further 90Y phantom, featuring a well-known and clinical-like activity will mimic the signal only condition. This result is used to extrapolate to different source sizes, after having estimated the background for various TNR. The obtained significance values suggest that the MT9V011 sensor is capable of distinguishing a signal from an estimated background, depending on the interplay among TNR, acquisition time and tumor diameter.
•A CMOS imager has been used as sensor for beta- emission from isotopes (90Y) of interest in Radioguided surgery.•Using a position scan a correlation between the source dimension and the shape of the response has been found.•The sensitivity of the sensor to tumor detection has been determined by studying the interplay among TNR, acquisition time and tumor diameter.
The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the ...possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.
Radio Guided Surgery (RGS) is a nuclear medicine technique allowing the surgeon to identify tumor residuals in real time with a millimetric resolution, thanks to a radiopharmaceutical as tracer and a ...probe as detector. The use of β− emitters, instead of γ or β+, has been recently proposed with the aim to increase the technique sensitivity and reducing both the administered activity to the patient and the medical exposure. In this paper, the possibility to use the commercial CMOS Image Sensor MT9V115, originally designed for visible light imaging, as β− radiation detector RGS is discussed. Being crucial characteristics in a surgical environment, in particular its stability against time, operating temperature, integration time and gain has been studied on laboratory measurements. Moreover, a full Monte Carlo simulation of the detector has been developed. Its validation against experimental data allowed us to obtain efficiency curves for both β and γ particles, and also to evaluate the effect of the covering heavy resin protective layer that is present in the “off the shelf” detector. This study suggests that a dedicated CMOS Image Sensor (i.e. one produced without the covering protective layer) represents the ideal candidate detector for RGS, able to massively increase the amount of application cases and the efficacy of this technique.
Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β− emitting tracers provides a higher signal to background ratio ...compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β− emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.
Cosmic rays have the potential to significantly affect the atmospheric composition by increasing the rate and changing the types of chemical reactions through ion production. The amount and states of ...ionization, and the spatial distribution of ions produced are still open questions for atmospheric models. To precisely estimate these quantities, it is necessary to simulate particle–molecule interactions, down to very low energies. Models enabling such simulations require interaction probabilities over a broad energy range and for all energetically allowed scattering processes.
In this paper, we focus on electron interaction with the two most abundant molecules in the atmosphere, i.e., N2 and O2, as an initial step. A set of elastic and inelastic cross section models for electron transportation in oxygen and nitrogen molecules valid in the energy range 10 eV – 1 MeV, is presented. Comparison is made with available theoretical and experimental data and a reasonable good agreement is observed. Stopping power is calculated and compared with published data to assess the general consistency and reliability of our results. Good overall agreement is observed, with relative differences lower than 6% with the ESTAR database.
•Cosmic rays ionization can significantly affect chemical reactions in the atmosphere.•The role of ions is still poorly explained by current atmospheric models.•We propose accurate physical models for electron impact interaction with N2 and O2.•We reimplemented these models in C++, and we obtained promising preliminary results.•These models will be included in Geant4-DNA in the near future.
•Test on radiomarked ex-vivo meningioma specimens confirmed feasibility of β-RGS.•Personalized minimal activity to be injected can be evaluated from PET images.•Effective dose is at a level of ...whole-body PET/CT and personnel exposure negligible.
Radio-guided surgery with β- decays is a novel technique under investigation. One of the main advantages is its capability to detect small (⩽0.1 ml) samples after injecting the patient with low activity of radiopharmaceutical. This paper presents an experimental method to quantify this feature based on ex-vivo tests on specimens from meningioma patients.
Patients were enrolled on the basis of the standard uptake value (SUV) and the tumour-to-non-tumour activity ratio (TNR) resulted from 68Ga-DOTATOC PET exams. After injecting the patients with 93–167 MBq of 90Y-DOTATOC, 26 samples excised during surgery were analyzed with a β- probe. The radioactivity expected on the neoplastic specimens was estimated according to the SUV found in the PET scan and the correlation with the measured counts was studied. The doses to surgeon and medical personnel were also evaluated.
Even injecting as low as 1.4 MBq/kg of radiotracer, tumour residuals of 0.1 ml can be detected. A negligible dose to the medical personnel was confirmed.
Radio-guided surgery with β- decays is a feasible technique with a low radiation dose for both personnel and patient, in particular if the patient is injected with the minimum required activity. A correlation greater than 80% was observed between the measured counts and the expected activity for the lesion samples based on the individual SUV and the TNR. This makes identifiable the minimum injectable radiotracer activity for cases where 90Y is the utilized radionuclide.
Highlights • A novel radio-guided-surgery technique using beta- radiation is under development. • Simulations and lab tests demonstrated its potential compared to state-of-the-art. • A ...proof-of-principle test on patient confirmed tracer uptake and probe sensitivity. • It also confirmed that the dose delivered to the medical staff is negligible. • This is a proof-of-principle, not a case report, nor a clinical trial.