Re-usable air/water and suction valves used in endoscopes often demonstrate risk of infection. To the authors' knowledge, the safety and efficacy of re-usable and single-use valves have not been ...compared to date. As such, a laboratory investigation was undertaken to compare the safety and efficacy of re-usable and single-use valves at 11 Italian endoscopy sites. Safety was evaluated by analysing the rinse liquid of reprocessed re-usable valves ready for use, and efficacy was assessed based on the completion of endoscopic procedures without valve malfunction. This study found significantly lower contamination of single-use valves compared with re-usable valves (0 vs 29.1%, respectively; P=0.007) and similar efficacy (97.6 vs 98.8%, respectively; P=ns). Microbiological analysis of the rinse liquid of reprocessed re-usable valves identified various surviving micro-organisms and highlighted their potential pathogenicity. Such data suggest that sterile single-use valves may be safer than re-usable valves, and have comparable performance.
Capsule endoscopy is considered the diagnostic procedure of choice in patients with obscure gastrointestinal bleeding (OGIB). Double-balloon endoscopy (DBE) offers both diagnostic and therapeutic ...potential, but is invasive, complex, and time-consuming. The aim was to evaluate diagnostic agreement between capsule endoscopy and DBE in patients with OGIB, and secondarily the diagnostic gain of DBE when capsule endoscopy detected only blood or clots in the small-bowel lumen.
Multicenter prospective study carried out at six institutions in Italy.
193 patients (119 men, mean age 61.6 +/- 16.2) first underwent capsule endoscopy and then DBE. The most frequent positive findings at capsule endoscopy were vascular lesions (74 patients, 38.3 %), blood or clot in the lumen (34, 17.6 %), and tumor mass (20, 10.4 %). The most frequent findings at DBE were vascular lesions (72 patients, 37.3 %), neoplasia (30, 15.5 %) and ulcers/inflammatory lesions (12, 6.2 %). Overall kappa coefficient was 0.46 (95 %CI 0.38 - 0.54), with maximum concordance for vascular (0.72 95 %CI 0.59 - 0.84) and inflammatory (0.78 0.58 - 0.99) lesions and minimum for polyps (0.46 0.16 - 0.80). Blood in the lumen was the only positive finding at capsule endoscopy in 34 cases; of these, 12 had negative DBE findings whereas 10 had vascular lesions, 6 neoplasia, 1 ulcer, and 5 diverticula.
Capsule endoscopy and DBE have good agreement for vascular and inflammatory lesions but not for polyps or neoplasia. DBE provides valuable adjunctive information, particularly in patients with neoplasia or polyp at capsule endoscopy. DBE clarified the origin of bleeding in two-thirds of patients with capsule endoscopy showing only blood in the lumen.
We propose an RF-based localization system that works using a single anchor node. The anchor is equipped with a switched-beam directional antenna that is installed on the ceiling of a room and ...collects signal strength information sufficient for absolute 2D target positioning. Indoor measurements are used to show satisfactory localization results with range-free (proximity), range-based and fingerprinting schemes.