The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by ...their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the total mass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5 × 5 × 18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.
Single-photon avalanche diode (SPAD) arrays fabricated in a 180-nm CMOS technology with a high-voltage option have been exposed to calibrated neutron and X-ray sources to evaluate their radiation ...tolerance. The technology is being investigated in view of the design of low material budget detectors for charged particle tracking based on the coincidence of the signals coming from two or more overlapping layers of SPAD sensors. Each element in the array is a monolithic detector including the processing electronics together with the diode in the same substrate. Different sensor dimensions and structures have been implemented in the test chip to thoroughly explore the technology features. This paper will present and discuss the results from the characterization, in terms of dark count rate, of SPAD arrays irradiated with X-ray doses reaching 1 Mrad(SiO 2 ) and with neutron fluences up to <inline-formula> <tex-math notation="LaTeX">10^{11}~1 </tex-math></inline-formula>-MeV neutron equivalent cm<inline-formula> <tex-math notation="LaTeX">^{-2} </tex-math></inline-formula>.
We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, ...corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical “drift model” of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.
The direct detection of high-energy cosmic rays up to the PeV region is one of the major challenges for the next generation of space-borne cosmic-ray detectors. The physics performance will be ...primarily determined by their geometrical acceptance and energy resolution. CaloCube is a homogeneous calorimeter whose geometry allows an almost isotropic response, so as to detect particles arriving from every direction in space, thus maximizing the acceptance. A comparative study of different scintillating materials and mechanical structures has been performed by means of Monte Carlo simulation. The scintillation-Cherenkov dual read-out technique has been also considered and its benefit evaluated.
A large interest has been triggered by the recent direct measurements of cosmic positrons and electrons. They include: the anomalous positron abundance reported by PAMELA; the spectral “feature” ...suggested by the analysis of the inclusive electron and positron data of the ATIC balloon experiment; the results of FERMI and H.E.S.S. experiments. Further accurate measurements, with smaller systematic errors, might clarify the present experimental scenario. While measurements of dipole asymmetries and of the electron spectrum above 1
TeV may require a space mission to provide a sufficient exposure, balloons can investigate the spectral shape below 1
TeV and contribute to the clarification of the, so-called, “ATIC anomaly”. A concise review will be presented of the main balloon missions that have been specifically designed to provide new electron measurements in the near future.
In this paper, we present the implementation and preliminary evaluation of a new type of silicon sensor for charged particle detection operated in Geiger-mode. The proposed device, formed by two ...vertically-aligned pixel arrays, exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. A proof-of-concept two-layer sensor with per-pixel coincidence circuits was designed and fabricated in a 150nm CMOS process and vertically integrated through bump bonding. The sensor includes a 48×16pixel array with 50μm×75μm pixels. This work describes the sensor architecture and reports a selection of results from the characterization of the avalanche detectors in the two layers. Detectors with an active area of 43×45μm2 have a median dark count rate of 3kHz at 3.3V excess bias and a breakdown voltage non-uniformity lower than 20mV.
In this paper, we present the analysis and results of a direct measurement of the cosmic-ray proton spectrum with the CALET instrument onboard the International Space Station, including the detailed ...assessment of systematic uncertainties. The observation period used in this analysis is from October 13, 2015 to August 31, 2018 (1054 days). We have achieved the very wide energy range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV covering, for the first time in space, with a single instrument the whole energy interval previously investigated in most cases in separate subranges by magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent with AMS-02 but extends to nearly an order of magnitude higher energy, showing a very smooth transition of the power-law spectral index from -2.81±0.03 (50-500 GeV) neglecting solar modulation effects (or -2.87±0.06 including solar modulation effects in the lower energy region) to -2.56±0.04 (1-10 TeV), thereby confirming the existence of spectral hardening and providing evidence of a deviation from a single power law by more than 3σ.
Dark count rate (DCR) increase in CMOS single-photon avalanche diodes (SPADs) exposed to a nonmonochromatic neutron source is modeled, taking into accountthe source spectrum and the geometry of the ...device under test. Experimental results from the characterization of SPADs fabricated in a 150-nm technology and irradiated with 1-MeV neutron equivalent fluences up to 1011 cm-2 are found to be in good agreement with the theoretically calculated distribution of the nonionizing energy deposited in the device substrate.
Extended results on the cosmic-ray electron + positron spectrum from 11 GeV to 4.8 TeV are presented based on observations with the Calorimetric Electron Telescope (CALET) on the International Space ...Station utilizing the data up to November 2017. The analysis uses the full detector acceptance at high energies, approximately doubling the statistics compared to the previous result. CALET is an all-calorimetric instrument with a total thickness of 30 X_{0} at normal incidence and fine imaging capability, designed to achieve large proton rejection and excellent energy resolution well into the TeV energy region. The observed energy spectrum in the region below 1 TeV shows good agreement with Alpha Magnetic Spectrometer (AMS-02) data. In the energy region below ∼300 GeV, CALET's spectral index is found to be consistent with the AMS-02, Fermi Large Area Telescope (Fermi-LAT), and Dark Matter Particle Explorer (DAMPE), while from 300 to 600 GeV the spectrum is significantly softer than the spectra from the latter two experiments. The absolute flux of CALET is consistent with other experiments at around a few tens of GeV. However, it is lower than those of DAMPE and Fermi-LAT with the difference increasing up to several hundred GeV. The observed energy spectrum above ∼1 TeV suggests a flux suppression consistent within the errors with the results of DAMPE, while CALET does not observe any significant evidence for a narrow spectral feature in the energy region around 1.4 TeV. Our measured all-electron flux, including statistical errors and a detailed breakdown of the systematic errors, is tabulated in the Supplemental Material in order to allow more refined spectral analyses based on our data.
Photon counting with a FDIRC Cherenkov prototype readout by SiPM arrays Marrocchesi, P.S.; Bagliesi, M.G.; Basti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2017, Letnik:
845
Journal Article
Recenzirano
A prototype of a Focused Internal Reflection Cherenkov, equipped with 16 arrays of NUV-SiPM, was tested at CERN SPS in March 2015 with beams of relativistic ions at 13, 19 and 30GeV/n obtained from ...fragmentation of an Ar primary beam. The detector, designed to identify cosmic nuclei, features a Fused Silica radiator bar optically connected to a cylindrical mirror of the same material and an imaging focal plane of dimensions ∼4cm×3cm covered with a total of 1024 SiPM photosensors. Thanks to the outstanding performance of the SiPM arrays, the detector could be operated in photon counting mode as a fully digital device. The Cherenkov pattern was recorded together with the total number of detected photoelectrons increasing as Z2 as a function of the atomic number Z of the beam particle. In this paper, we report on the characterization and test of the SiPM arrays and the performance of the Cherenkov prototype for the charge identification of the beam particles.